Centrum KD2 

- 13 - 

Centrum KD2 VR 

FUNCTIONING OF “TCL” 

KEYPAD 

KEYPAD DISPLAY 

 

Indicates the state of the panel

 

 

Off

 All 

areas 

disarmed 

 

On

 

All areas armed 

 

Flash each 2s 

Control panel partially armed 

 

Blinking

 

In Entry/Exit Path 

 

Bypass Led

 

 

Off

 No 

bypassed 

zone 

 

On

 

There is a bypassed zone 

 

Blinking

 

Unprogrammed clock 

 

Feeding Led

 

 

Off

 

Correct Supply 

 

On

 

Fail in Mains power (220Vac) 

 

Blinking

 Low 

Battery 

 

Alarm Memory Led

 

 

Off

 

No Alarm memory 

 

On

 

There is Alarm memory 

 

Blinking

 

Failure in zone. 

The Display shows the Panel State and also a message in 
the upper line, called Identifier. 

Identifier

Status Leds

System Information

Panel State

JR

 

The state info shown is: 

1 2 

Disarmed Areas 

Failure in a zone 

Unprogrammed clock 

Bypassed Zones 

Mains power supply fail. 

Low Battery 

Alarm memory 

Failure in the alarm transmitter. 

If a wrong code is introduced or a error is produced in any 
function the LCD will show 

ERROR 

IN FUNCTION 

KEYPAD BUZZER 

The keypad has a buzzer that advise acoustically the 
control panel state when arming or carrying out some 
function. 

There are the following buzzer sounds: Entry path / Exit path 
/ Day zone / (chime) detection / Intrusion alarm / Fire pre-
alarm / Fire alarm / Keypad  tactile sound / Wrong code / 
ring / Disarming. 

There are some sounds that can be deleted by 

programming ( entry/exit path) and more, through direct 
functions from the keypad ( chime and day zone). 

PANEL IN STAND-BY 

When the panel is in standby the display shows the 
disarmed areas, if any area is armed it won’t be shown. 
Each 8 seconds the keypad will show a sinoptic of the 
system State as: 

Status :   --------- 

Ta: 14.0 C V 14.1 

In status it can appear: 

 

All Armed  : All the system areas are armed. 

 

All OFF 

: All the system areas are disarmed. 

 

Part Armed : Some areas are armed and other 

disarmed. 

 

T

a

 : Indicates the  temperature in Celsius 

 

V : Voltage at the power supply input of the 

keypad. 

Zones Detection 

If panel disarmed, the detection of a disarmed zone is 
shown in the LCD as. 

Zones in Detect. 

[Alias of Zone] 

 This displaying will last until the zone restores and stops 
detecting, if there are several zones detecting they will be 
shown sequentially. 

ARMING / DISARMING  

In order to arm/disarm de control panel, introduce a valid 
user code and then press E : 

User code  +  E

 

Changes panel 

state 

In case of having more than one area on the system, and 

in order to assure the arming / disarming of the user areas, 
use the absolute arming / disaming function just like: 

User Code  +  F1

 

+  E  Always 

arms 

User Code  +  F2

 

 

Always 

disarms 

Afted done, the display will show: 

Arming  

Disarming 

[Alias of User] 

 

[Alias of User] 

If after disarming, any zone had caused an alarm during 
the last arming, the keypad will show which zones had 
caused alarm and the speaker will play them: 

Last Alarms in: 

[ Alias of zones ] 

Also if after disarming there were zones in failure, they will 
be indicated in the display as:  

Zone Failure 

[Alias of zones] 

Also if after disarming there were system outputs in failure, 
they will be indicated in the display. 

Output Failure 

[Alias of outputs] 

Содержание centrum KD2

Страница 1: ...User s Guide Ver 5 12 7...

Страница 2: ...duct and for trusting in our company This product fulfils all the security regulations it has overcome rigorous tests in process production and it is designed to offer you and your client the personal...

Страница 3: ...rry out using the Night arming and will arm the areas of the user that carries out the function and will bypass the zones programmed with the Night Arming bypass feature This is done by User code F1 E...

Страница 4: ...d detects the control panel will activate the output that has assigned and the phone communicator send the ambush report The keypad not show anything and the buzzer will not sound FIRE ALARM If there...

Страница 5: ...ce carried out the On and Off tones will be played indicating the state of the areas of the user code Activate Deactivate Outputs Press and then Output number the panel will reproduce the current stat...

Страница 6: ...t and will keep lit until restoring the zone stop detecting ARMING DISARMING In order to arm disarm de control panel introduce a valid user code and then press E User code E Changes panel state In cas...

Страница 7: ...ound F1 1 Police sends the police report to the central receiver F2 4 Fire sends the firemen report to the central receiver F3 7 Ambulance sends the medical assistance report to the central receiver F...

Страница 8: ...isplay will show If it s desired to store the programmed data press F1 If it s desired to modify the data enter the new data and press E USER CODES PROGRAMMING User code 1 001 1 1 1 1 User code 2 002...

Страница 9: ...deleted by programming entry exit path and more through direct functions from the keypad chime and day zone low bat of wireless detector PANEL IN STAND BY With PANEL disarmed the Display shows the sta...

Страница 10: ...eans that there are no more events to show Example Alarm in zone 9 25 of August at 12 45 0 9 1 2 4 5 2 5 0 8 4 Output Test activates the PANEL outputs during 2 seconds If is pressed before the keypad...

Страница 11: ...Master code from factory is 1111 After that the display will show It s not possible to access to user programming if PANEL is in Alarm Exit programming To exit programming press sequentially E The pa...

Страница 12: ...hange the telephone numbers for private call in case you change your mobile private number or telephone Company Private phone n 1 Example Tel 1 123456789 with dial tone detection 200 D 1 2 3 4 5 6 7 8...

Страница 13: ...BY When the panel is in standby the display shows the disarmed areas if any area is armed it won t be shown Each 8 seconds the keypad will show a sinoptic of the system State as Status Ta 14 0 C V 14...

Страница 14: ...5 produced events beginning with the most recent If no code is typed before pressing 3 the keypad will show a and the zones that have caused alarm during the last arming period The display shows the E...

Страница 15: ...vated To modify or remain the state press the suitable key F22S E Changes the State F1 Remain in same state Enabling disarming of the Maid code Press the code and press the function key User Code F32S...

Страница 16: ...5 PRIVATE PHONES PROGRAMMING In theses addresses you can change the telephone numbers for private call Private phone Ex Tel 1 1234567 with dial tone detection 200 D 1 2 3 4 5 6 7 F F E Private Phone 2...

Отзывы: