Centrum KD2
- 13 -
Centrum KD2 VR
FUNCTIONING OF “TCL”
KEYPAD
KEYPAD DISPLAY
Indicates the state of the panel
Off
All
areas
disarmed
On
All areas armed
Flash each 2s
Control panel partially armed
Blinking
In Entry/Exit Path
Bypass Led
Off
No
bypassed
zone
On
There is a bypassed zone
Blinking
Unprogrammed clock
Feeding Led
Off
Correct Supply
On
Fail in Mains power (220Vac)
Blinking
Low
Battery
Alarm Memory Led
Off
No Alarm memory
On
There is Alarm memory
Blinking
Failure in zone.
The Display shows the Panel State and also a message in
the upper line, called Identifier.
Identifier
Status Leds
System Information
Panel State
JR
The state info shown is:
1 2
Disarmed Areas
V
Failure in a zone
H
Unprogrammed clock
O
Bypassed Zones
R
Mains power supply fail.
B
Low Battery
A
Alarm memory
T
Failure in the alarm transmitter.
If a wrong code is introduced or a error is produced in any
function the LCD will show
ERROR
IN FUNCTION
KEYPAD BUZZER
The keypad has a buzzer that advise acoustically the
control panel state when arming or carrying out some
function.
There are the following buzzer sounds: Entry path / Exit path
/ Day zone / (chime) detection / Intrusion alarm / Fire pre-
alarm / Fire alarm / Keypad tactile sound / Wrong code /
ring / Disarming.
There are some sounds that can be deleted by
programming ( entry/exit path) and more, through direct
functions from the keypad ( chime and day zone).
PANEL IN STAND-BY
When the panel is in standby the display shows the
disarmed areas, if any area is armed it won’t be shown.
Each 8 seconds the keypad will show a sinoptic of the
system State as:
Status : ---------
Ta: 14.0 C V 14.1
In status it can appear:
−
All Armed : All the system areas are armed.
−
All OFF
: All the system areas are disarmed.
−
Part Armed : Some areas are armed and other
disarmed.
−
T
a
: Indicates the temperature in Celsius
−
V : Voltage at the power supply input of the
keypad.
Zones Detection
If panel disarmed, the detection of a disarmed zone is
shown in the LCD as.
Zones in Detect.
[Alias of Zone]
This displaying will last until the zone restores and stops
detecting, if there are several zones detecting they will be
shown sequentially.
ARMING / DISARMING
In order to arm/disarm de control panel, introduce a valid
user code and then press E :
User code + E
=
Changes panel
state
In case of having more than one area on the system, and
in order to assure the arming / disarming of the user areas,
use the absolute arming / disaming function just like:
User Code + F1
+ E Always
arms
User Code + F2
+
E
Always
disarms
Afted done, the display will show:
Arming
Disarming
[Alias of User]
[Alias of User]
If after disarming, any zone had caused an alarm during
the last arming, the keypad will show which zones had
caused alarm and the speaker will play them:
Last Alarms in:
[ Alias of zones ]
Also if after disarming there were zones in failure, they will
be indicated in the display as:
Zone Failure
[Alias of zones]
Also if after disarming there were system outputs in failure,
they will be indicated in the display.
Output Failure
[Alias of outputs]