Страница 1: ...nstalaci n 47 IT Manuale di installazione ed uso 56 DE Montage und Bedienungsanleitung 65 NL Installatie en montagehandleiding 74 Figures Pictures 83 Monterings og bruksanvisningen m oppbevares under...

Страница 2: ...output 6 0 kW 9 0 kW Smoke gas mass flow 5 4 g s 8 1 g s Rec chimney draught 12 Pa 12 Pa Effiency 83 4 9 kW 80 9 9 kW CO emission 13 O2 0 08 0 06 Flue gas temperature 240 0 C 314 0 C Operating mode I...

Страница 3: ...ctly on a combustible floor if the floor is covered with a plate made of metal or or other non combustible material The recommended minimum thickness is 0 9 mm The whole floor inside the surround must...

Страница 4: ...have a certain flexibility in order to prevent movement in the installation leading to cracks N B A correct and sealed connection is very important for the proper functioning of the product Warning We...

Страница 5: ...e adapted to the insert 3 The flue pipe bend should be assembled directly onto the insert and should be able to rotate 360o Pipe 150 mm is assembled on the inside of the smoke outlet and the 175 mm is...

Страница 6: ...are the correct size The size of the logs should be Kindling Length Approx 35 40 cm Diameter 3 5 cm Amount per fire 8 10 pieces Firewood split logs Mini Maxi Recommended length 35 cm 35 kg Diameter A...

Страница 7: ...mwaterandaddsomeashfrom theburnchamber Rubit over the glass and then clean the glass with clean water Dry well If it is necessary to clean the glass more thoroughly we recommend using a glass cleaner...

Страница 8: ...ection 2 Pull the air chamber forward while at the same time lifting it up at the edge Edge it down and remove it through the opening in the door Be aware that the part is heavy 3 Before replacing the...

Страница 9: ...ooting Poor draught Check the length of the chimney and that it complies with national laws and regulations Make sure that the minimum cross section on the chimney is large enough See also 2 0 Technic...

Страница 10: ...high 340995 2 units of 103x573 1 Remove the front see relevant section on 7 0 Service 2 Attach the panels A with countersunk head screws through the 2 slits at the sides of the combustion chamber Make...

Страница 11: ...83...

Страница 12: ...84 B C A D A B C A G F E D B A C H A B Fig 5 750 cm 2 500 cm 2 600 cm 2 C 350 cm 2 Fig 4 Fig 2 Fig 6 Fig 3 A D B C Fig 7 A Fig 8 E C D B A Fig 9 Mini Maxi...

Страница 13: ...85 A B B A A B B A Fig 11 g 10 E D C B A Fig 13 C E A B D ig 12 C B A B C D A Fig 15 ig 14...