background image

 

MODEL MARQUIS AGDVT-38/AGDV-38  

DIRECT VENTED BUILT-IN  

GAS FIREPLACE  

FOR USE WITH NATURAL GAS AND PROPANE 

 

INSTALLATION AND OPERATING INSTRUCTIONS 

FOR YOUR SAFETY 

 

DO NOT store or use gasoline or any other flammable vapors or liquids in the vicinity 
of this or any other appliance 

 

IF YOU SMELL GAS: 
-   Do not try to light any appliance.  
-  Open windows. 
-  Do not touch electrical switches. 
-  Extinguish any open flame. 
-  Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier’s 

instructions. 

-  If you cannot reach the gas supplier, call the fire department. 

PLEASE READ INSTRUCTIONS CAREFULLY BEFORE INSTALLING AND 

OPERATING THE APPLIANCE 

 

WARNING:

 

Improper installation, adjustment, alteration, service or maintenance voids 

all the manufacturer’s warranties and may cause property damage, personal injury or 
loss of life. 

 

Installation and service must be performed by a qualified installer, service agency or the 
gas supplier. 

 Installer, please leave this manual with the appliance owner for future reference. 

WARNOCK HERSEY 

CERTIFIED FOR CANADA AND USA 

NOT FOR USE WITH SOLID FUEL 

200-0044 

 

24MAY01 

f i r e - p a r t s . c o m

Summary of Contents for AGDV-38

Page 1: ...s phone Follow the gas supplier s instructions If you cannot reach the gas supplier call the fire department PLEASE READ INSTRUCTIONS CAREFULLY BEFORE INSTALLING AND OPERATING THE APPLIANCE WARNING Improper installation adjustment alteration service or maintenance voids all the manufacturer s warranties and may cause property damage personal injury or loss of life Installation and service must be ...

Page 2: ...peration Instructions 14 15 Maintenance 16 Trouble Shooting Instructions 17 18 Servicing 19 20 Important Information Form 21 Warranty 22 Replacement Parts 23 Allowed Termination Location 24 Warranty Registration Form 25 Page Manufactured by Archgard Industries Ltd British Columbia Canada Patents Pending fire parts com ...

Page 3: ...provide you with many years of enjoyment CAUTION Due to high temperatures the appliance should be located out of traffic and away from furniture and draperies Children and adults should be alerted to the hazards of high surface temperature and stay away to avoid burns or clothing ignition Young children should be carefully supervised when they are in the same room as the appliance Clothing or othe...

Page 4: ...Canada Electrical connections and grounding must conform with local code or current National Electrical code ANSI NFPA No 70 1987 in the US and in Canada the current Canadian Electrical Code CSA C22 1 HIGH ALTITUDE INSTALLATION When installing this appliance beyond 4500 ft 1372 m above sea level The appliance must be properly de rated and installed according to local codes In the absence of local ...

Page 5: ...onal TOP LOUVERS GLASS DOOR APPLIANCE DIMENSIONS FRONT VIEW 38 23 1 2 39 3 4 TOP VIEW SIDE VIEW FRONT VIEW 3 Except for the vent connector locations the rear vented DV 38 and top vented DVT 38 have the same physical dimensions 6 1 4 32 29 3 4 21 1 4 31 1 16 16 1 4 fire parts com ...

Page 6: ...accessible for venting See PAGE 24 ALLOWABLE TERMINATION LOCATIONS VENT TERMINATION 1 See ALLOWABLE TERMINATION LOCATIONS diagram page 24 to establish a suitable vent termination location 2 In heavy snowfall areas make sure vent termination is located where it can not be blocked by snow from snow removal equipment 3 Locate vent termination away from plants bushes or any other object on or near the...

Page 7: ...t 6 FRAMING DIMENSIONS 38 16 1 4 38 1 2 26 1 4 38 54 38 32 1 4 16 1 4 If more rigidity is required A stud may be added to the back of the top nailing flange after the fireplace is installed TERMINATION FRAMING 11 10 fire parts com ...

Page 8: ...venting chart given in this manual 5 Use a vent spacer between the inside and outside flex vents at every 3 ft intervals 6 Never slope horizontal running vents downwards 7 VERY IMPORTANT Maintain at least an upward slope of 1 for every 1 ft of horizontal run on the rear vented models 8 Terminate the vent with a vent termination supplied by Archgard Industries Ltd 9 Support horizontal running vents...

Page 9: ...vent locate the restrictor in the exhaust section fitting into the formed lip Restrictor Placement WARNING These restrictors are only to be installed in the vent system if the vent exceeds 7 in vertical height Restrictor Number 1 below is required Installing them under any other circumstances may cause hazardous venting conditions and may result in personal injury property damage or death NOT FOR ...

Page 10: ...to center of termination 7 ft Venting in this area may require a vent restrictor plate 1 5 ft 7 ft 9 ft 11 ft 13 ft 31 Heater Vertical Venting between 10 and 24 ft Rooftop Termina tion requires a vent restrictor plate 2 VERTICAL VENTING THROUGH THE ROOF FOR ROOFTOP VENTED APPLIANCES Use only Simpson Duravent 4 x 6 5 8 direct vent systems and Simpson Duravent venting components Maximum vertical hei...

Page 11: ...The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 5 kPa Failure to do so will damage the appliance s gas valve Such damage is not covered by the manufacturer s warranty Check for proper gas supply pressure by loosening the set ...

Page 12: ...are two latches under the firebox Undo the latches swing the bottom of the door away from the appliance and then lift the door off the top retaining tabs Carefully place the door in a safe location where it cannot be scratched or damaged Replacing the Glass Door The reverse procedure of Removing the Glass Door Buckle latch Buckle latch Top of door hooks onto fireplace fire parts com ...

Page 13: ... is provided with the heater Place the fibre coals on the burner tray surrounding the burner DO NOT place fibre coals on the burner itself Tear ember wool into 1 2 to 3 4 diameter ember pieces and place them on the edges of the burner so as to hide the transition between the fibre coals and the burner Keep the embers from obstructing the burner ports Do not add any materials to the burner other th...

Page 14: ...bottom of the gas fireplace Be sure to connect a grounding wire to the side of gas fireplace Use any screw hole on the side for this purpose Slide the thermal snap switch into the fork like bracket underneath the left side of the firebox Neatly tie down and tuck the wires down at the bottom and to the back of the fireplace CAUTION Do not allow any wires to touch the bottom of the firebox Otherwise...

Page 15: ... the appliance area for gas Be sure to smell next to the floor because some gases are heavier than air and will settle on the floor IF YOU SMELL GAS follow the instruction on the front cover of this manual A B C D INITIAL OPERATION Check that the appliance is properly vented and connected to the gas supply Check that the logs and branches are properly placed Check all external parts such as grills...

Page 16: ...oper lighting of pilot Press slightly and turn control knob counterclockwise 4 to PILOT position depress control knob and light pilot by repeatedly pressing the sparker Venting of air may take place at the pilot prior to the flow of fuel gases Once flame is established hold knob depressed for approximately 60 sec START UP PROCEDURE 1 2 3 4 5 6 Turn thermostat to the desired comfort level or turn O...

Page 17: ...utside the house wearing a dust mask The logs are very fragile take care not to break them After cleaning the logs must be replaced as per the instructions in this manual When replacing glass door ensure the gasket is still secure all around the edge of the glass and it is sealing against the firebox frame Replace the gasket is worn damaged or falling off Once a Year have a qualified service techn...

Page 18: ...gas valve may be defective Pilot will not remain on after being lit 1 Press the control knob all the way in 2 Hold the control knob in for a longer period of time 3 If you are trying to re light the pilot immediately after you have shut off the pilot you have to wait a few minutes for the valve to reset 4 Check to see if the pilot flame is large enough to reach and surround the thermocouple If the...

Page 19: ... primary air by opening the primary air shutter 2 Check for proper placement of the logs and branches See that section in the instruction manual 3 Check for obstruction of the burner ports by the embers See that section in the instruction manual 4 Check for proper venting and blockage of the vent termination 5 Check manifold pressure and clock input rating Sharp blue flames with flames lifting off...

Page 20: ... shutter screw with a Philips screwdriver Rotate air shutter with a flat tip screw driver The primary air opening size can be easily seen with a flashlight Tighten the air shutter screw after adjustment CAUTION Adjust the primary air opening according to the shutter settings as specified on page 3 Ensure the appliance is cool to the touch prior to servicing ADJUSTING PRIMARY AIR SERVICING UNDER WA...

Page 21: ...assembly plate to the appliance Gently lift the assembly up and tilt the back up to clear the front of the valve from the opening Replacing the assembly is the reverse of the above instructions Disconnect power to the gas fireplace Remove the fan speed mounting bracket The convection blower is located at the bottom of the appliance at the back Remove the three screws holding the blower Rotate the ...

Page 22: ...SS PHONE NUMBER COMPANY NAME ADDRESS PHONE NUMBER APPLIANCE MODEL NUMBER MARQUIS DV38E DVT 38 SERIAL NUMBER GAS TYPE NATURAL GAS LPG VALVE TYPE DEXON DATE PURCHASED INSTALLATION INSTALLER NAME DATE INSTALLED GAS TYPE NATURAL GAS LPG GAS SUPPLY PRESSURE in w c VENT MFG VENT VERTICAL HEIGHT ft VENT CAP MFG VENT HORIZONTAL LENGTH ft OWNER RETAILER INSTALLER MODIFICATIONS INSTALLER S SIGNATURE 21 fire...

Page 23: ...n doubt OBTAINING WARRANTY SERVICE To obtain warranty service the consumer shall return the defective part to the original selling dealer transportation prepaid along with the serial number of the appliance and proof of purchase Any defective part in our judgment will be repaired or replaced at Archgard s discretion The dealer must obtain approval from an authorized Archgard representative before ...

Page 24: ...PIEZO IGNITOR C W NUT JBS 66270 003 1 EA 308 0007 PIEZO IGNITOR FOR MOUNTING ON VALVE SIT 1 EA 308 0022 VALVES DEXEN NG 3 5 WC 3 8X3 8 6003S 1 EA 308 0054 PILOT ASSEMBLY CONVERTIBLE PILOT LP SIT 1 EA 308 0055 PILOT ASSEMBLY CONVERTIBLE PILOT NG SIT 1 EA 308 0085 VALVE LP S I T NOVA NO TURNDOWN 1 EA 310 0009 COALS MEDIUM GRADE 4OZ BAG 1 EA 310 0024 LOGSET 4 PC SET DV36E DV38 FH520 1 SET 310 0046 MI...

Page 25: ...24 fire parts com ...

Page 26: ...____________________ Telephone ______ ______ _________ Dealer s Name Address ______________________________________________________ ______________________________________________________ Installer s Name Address _____________________________________________________ _____________________________________________________ Why did you choose this product ________________________________________________...