Wood consumption
Jøtul I
150
FL
has a nominal heat output of
6,0
kW. Use of wood,
with nominal heat emission: Approx.
2,1
kg/h
. Another important
factor for proper fuel consumption is that the logs are the correct
size. The size of the logs should be
:
Kindling:
Length: 20 - 40 cm
Diameter: 2 - 5 cm
Amount per fire: 6 - 8 pieces
Firewood (split logs):
Length: 30 cm
Diameter: Approx. 8 cm
Intervals for adding wood: Approximately every 45 minutes
Size of the fire: 1,7 kg
Amount per load: 2 pieces
Nominal heat emission is achieved when the air wash vent is
open approximately 50%.
3.0 Installation
3.1 Floor
Foundations
It must be ensured that the foundations are dimensioned for
the fireplace. Cf.
«2.0 Technical data»
for specification of weight.
It is recommended that flooring which is not fastened to the
foundations – so-called floating flooring – is removed during
installation.
Requirements for protection of wooden
flooring
Jøtul I
150
FL has a heat shield underneath which protects the
floor from radiation. The product can therefore be placed directly
on a wooden floor that is covered by a metal plate or other
suitable, non-inflammable material. The recommended minimum
thickness is 0,9 mm. The entire floor within the surround must
be covered.
Any flooring made of combustible material, such as linoleum,
carpets, etc. must be removed from under the floor plate.
Requirement for protecting combustible
flooring in front of fireplace
The front plate must be in accordance with national laws and
regulations.
Contact your local building authorities regarding restrictions and
installation requirements.
3.2 Wall
Distance to walls protected by a firewall-see fig. 1
Firewall requirement
The firewall must be at least
100 mm
thick and be made of
brick, concrete-stone or light concrete. Other materials and
constructions with satisfactory documentation may also be
used.
Contact your local building authorities regarding restrictions and
installation requirements.
Distance from the stove to firewall:
The distance must be
minimum 15 mm
.
Requirements for the stove surround
Note that the entire wall within the surround must be covered
by insulation.
If the stove cowling is bricked up to the ceiling and the ceiling is
made of combustible material, on top of the warming chamber
and the cowling vents an extra ceiling panel must be installed
to avoid heating the ceiling.
For example use:
Rock wool
100 mm
thick on top of a steel plate min. 0,9 mm.
Ensure airing out the top of the stove cowling – for example an
opening towards the ceiling, or approx.
5
cm
2
opening
(fig. 2)
.
Note: Remember that it should be possible to sweep and to
inspect the installation.