Jøtul GF 400 CF Скачать руководство пользователя страница 5

5

General Information

 

This product has been approved to the European 

Standard EN 63:000 and is in accordance with EC 

Gas Appliances Directive (90/396/EEC).

 

The Flue must be checked for soundness and swept 

prior to installation it should only be used if clean and 

in good order.

 

Before installation, ensure that the local distribution 

conditions and the adjustment of the appliance are 

compatible.

 

This appliance incorporates a spillage monitoring 

device (TTB) this device will shutdown the appliance 

in the event of interruption to the evacuation of com-

bustion products. I.e. Flue Blockage.

 

If the appliance spillage monitoring device (TTB) 

should operate and close down the appliance, a mini-

mum period of 3 minutes should be observed before 

following the lighting instructions detailed in the 

USER section of this manual. 

 

If the appliance spillage monitoring device (TTB) 

shuts down the appliance repeatedly the appliance 

should not be used and a qualified service engineer 

should be called for service. 

 

This product, the Jøtul GF 

400

 CF, may only be used 

with Natural Gas G0 or be converted for the use of 

Propane G3. 

 

Assembly, installation and maintenance must be 

performed by a qualified person in accordance with 

the instructions for assembly, Installation and use 

enclosed with the product. The installation may only 

be operated after it has been inspected by a quali-

fied person and a certificate of completion has been 

issued. 

 

The Installation should be carried out in accordance 

with the Building Regulations which include the fol-

lowing standards for installation and maintenance 

of flues, ventilation and installation of Gas Fires. For 

UK BS5440:, BS5440:, BS587 for Republic of Ireland 

IS83, ICP3, IS37

 

The appliance is designed as a freestanding unit and 

no additional fixing methods need apply. 

 

This appliance is intended for use on a gas installation 

with a governed gas supply. 

Safety Precautions

 

This appliance must be installed in accordance with the 

rules in force. Consult instructions before installation 

and use of this appliance.

 

The appliance is designed as a heating device and all 

components will become hot (excluding control knob, 

control cover and control switch) care should be taken 

not to touch unit when it is in operation.

 

Warning! If you detect an odour of gas: 

• Do not light the Stove or any other appliance. 

• Do not use electrical switches or the telephone. 

• Contact your gas supplier’s emergency number.

 

The appliance must only be installed and repaired by 

qualified personnel. Always turn off the gas supply 

before service.

 

The appliance must be inspected following installation 

and at least once a year by qualified personnel.

 

The appliance must only use gas of the correct type and 

pressure See technical data for more details.

 

If Propane G3 is to be used, the appliance must be 

converted using the conversion instructions and kit 

supplied by Jøtul .This is only to be installed by qualified 

personnel.

 

It is permitted to install the appliance against a wall 

made of combustible material with the clearances 

specified in figs. 5-6.

 

The minimum clearance to combustible material in 

front of the appliance is 600 mm.

 

Curtains may not be placed within 600 mm above the 

appliance.

 

Never store combustible gas or liquid in the same room 

with the appliance.

 

Never light the appliance without the front glass in 

place or if the glass is cracked. Replacement  of the glass 

should be done by a licensed or qualified service person.  

Only remove glass for routine service.  Always handle 

glass carefully.

 

Do not burn solid fuel in the appliance.

 

Do not place combustible material on or near the appli-

ance, as the appliance becomes hot.

 

This appliance becomes hot in use so it advisable to 

keep young children, the aged or infirm and animals at 

a safe distance using a fire guard conforming to BS6539 

or BS6778 to provide extra protection.

Содержание GF 400 CF

Страница 1: ...DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas sup plier from a neighbor s phone Follow the g...

Страница 2: ...n Company Date Service details Annual service year 5 Sign Company Date Service details Annual service year 6 Sign Company Date Service details Annual service year 7 Sign Company Date Service details A...

Страница 3: ...aller Information 6 5 User Information 12 6 Troubleshooting 14 THIS OWNER S MANUAL PROVIDES INFORMATION TO ENSURE SAFE INSTALLATION AND EFFICIENT DEPENDABLE OPERATION OF YOUR STOVE PLEASE READ THESE I...

Страница 4: ...p Flue Nett 77 9 78 2 Efficiency Class 2 2 NOx Class 4 5 Main Burner Injector Marking 33 51 Pilot Injector Marking 51 30 Notes The appliance is supplied at the default factory settings for Natural Gas...

Страница 5: ...intended for use on a gas installation with a governed gas supply Safety Precautions This appliance must be installed in accordance with the rules in force Consult instructions before installation and...

Страница 6: ...all not be put out of operation by the installer When the TTB is exchanged only original manufacturer s parts shall be used Installation Guide for Qualified Personnel Important The appliance is factor...

Страница 7: ...he appliance shuts off in operation for no apparent reason especially during windy or stormy conditions and will not relight it is possible that the flue system safety switch has operated Allow the ap...

Страница 8: ...ppliance and connect to the gas supply and carry out a smoke test on the flue as described in the relevant section of this manual Assembly Prior To Installation The product is delivered in 1 package I...

Страница 9: ...e embers realistically simulate glowing coals when the burner is operating These should be spread evenly over the burner plate and around the logs 1 Engage the holes in the underside 0f the Right Log...

Страница 10: ...awn into the flue and no smoke should spill into the room If the smoke does issue into the room leave for another 5 minutes and retest The appliance is fitted with a TTB flue sensing safety switch If...

Страница 11: ...this dimension is preset at the factory For Propane 18 5 mm must be set by installer CAUTION To avoid burns do not adjust the air shutter until the burner has cooled down Figure 22 Safety switch loca...

Страница 12: ...vide extra protection Operating Instructions Lighting Note Odors when using the stove When used for the first time the appliance may emit an irritating gas that may smell a little The gas is not toxic...

Страница 13: ...sing the stove for the first time Adjusting the Heat Setting Heat and flame size can be adjusted by turning the regu lator knob C marked HI LOW which is located next to the gas control knob see fig 23...

Страница 14: ...and when the valve is being replaced Troubleshooting When No Spark is Generated at the Pilot Head It is uncommon for the Piezo spark ignitor fig 25 A to fail unless it has mechanical damage If the spa...

Страница 15: ...for at least 30 seconds Make sure the flame is centred at the thermo couple Make sure the thermocouple is enveloped by the flame up to at least 3 mm 1 8 from the tip fig 20 If the flame is abnormally...

Страница 16: ...at there are 2 threaded holes fig 16 B and C that can be used when installing a new thermocouple Make sure the blue wire A is fastened at the same threaded hole The nut on the thermocouple must not be...

Страница 17: ...ral Gas Open 21 5 mm Warning To avoid burns do not adjust the air open ing until the burner has cooled down Blocked orifice Make sure the main orifice fig 28 is dirt free and that the orifice has the...

Страница 18: ...18 ONLY USE REPLACEMENT PARTS PROVIDED BY AN AU THORIZED J TUL DEALER Figure 29 J tul GF 400 CF Illustrated Parts Breakdown...

Страница 19: ...220641 Burner Orifice LP 1 70 mm 045027 38 Air Shutter 220790 39 Gasket 2 25 OD 118023 40 Wing Nut M6 117975 41 Washer 2 25 OD 220734 42 Screw 8 x 3 4 117986 43 Pilot Assembly NG 129471 44 Spacer Pil...

Страница 20: ...nformance with local and national building regulations Before beginning the installation it is important that the these instructions be carefully read and understood J tul maintains a policy of contin...

Отзывы: