4
330 mm
4 mm
336 mm
CL
673 mm
LC
Jøtul GF
400
CF
Technical Information
Countries of Destination GB, IE
Appliance Category
II
H3P
Gas Types
NG LPG
(G0)
(G3)
State of Adjustment
I
H
I
3P
Supply Pressure (mbar)
0 37
Nominal Heat Input (Nett, kW) 8.7 9.3
Maximum Gas Consumption at
Full Rate: (m
3
/h at 5°C 03.5mbar) 0.90 0.380
Maximum Gas Consumption at
Full Rate: (kg/h at 5°C 03.5mbar) - 0.58
Burner Pressure at Full Rate –
Hot (mbar):
9.0 5.6
Efficiency:
Rear Flue (Nett, %)
79. 79.0
Top Flue (Nett, %)
77.9 78.
Efficiency Class
NOx Class
4 5
Main Burner Injector Marking 33 5
Pilot Injector Marking
5 30
Notes:
The appliance is supplied at the default factory
settings for Natural Gas (G0 at 0 mbar)
The appliance will have this setting following
conversion to LPG (G3 at 37 mbar)
Material:
Cast iron/steel
Finish:
Enamel or Matte Black paint
Flue outlet:
Top or Rear
Vent system: BV-standard system
Weight:
Approx. 86 kg (product)
PIN:
0063BS5908
Product dimensions: See figs. , , 3.
Figure 3. Rear Exit Flue Collar.
330 mm
Rear Exit
597 mm
CL
7 mm
With Short Legs, reduce height by /4” ( 5 mm)
Figure 2. Top Exit Flue Collar.
609 mm
7 mm
679 mm
Figure 1. Top View dimensions.