8.  Check the voltage generated by the thermopile (see fig 

7). Connect the multimeter with plus to one cable clip 

(D). Connect minus to the other cable clip. Light the pi-

lot and make sure the control knob remains on “PILOT” 

(fig. 3-B). At this point the multimeter should show 

500-700mV.

9.  Reconnect the wires to the valve and make sure only 

the ON/OFF/STAT switch is connected.

0. Turn the control knob on the valve to “ON” and turn the 

ON/OFF/STAT switch to “ON”. At this point the multi-

meter should show more than 300 mV.

. If a thermostat or remote control is to be connected, it 

can be done now. At this point the multimeter should 

show more than 75 mV.

Make sure the flame is centred at the thermocouple. 

Make sure the thermocouple is enveloped by the flame 

up to at least 3 mm from the tip (see fig.0). Check the 

voltage generated by the thermocouple. Connect the 

multimeter (fig.6-E) with plus to the ball point (D) at the 

end of the copper wire. Connect minus to the copper wire. 

Light the pilot (A) and hold in the control knob to prevent 

the flame on the pilot burner from going out.  At this 

point the multimeter should show 4-8 mV. the thermo-

couple. Note that there are  threaded holes (fig. 6-B) and 

(C) that can be used when installing a new thermocouple. 

Make sure the blue wire (A) is fastened at the same 

threaded hole. The nut on the thermocouple must not be 

tightened too much, just a / turn. If the gas pressure is 

correct and the possible faults above have been checked, 

the pilot flame can be adjusted with the adjusting screw. 

The gas volume is increased when the screw is turned 

anti-clockwise.

When There is No Gas Supply to the 

Burner.

This is the trouble-shooting procedure for the electrical 

components:
.  Make sure the control knob on the valve is set to “ON”.   

Check the position on the “ON/OFF/Thermostat” switch 

at the back of the appliance. It should be set to the ON 

position.

.  Make sure the wire from the valve to the “ON/OFF/

STAT” switch is connected correctly.

This is the trouble-shooting procedure for the thermopile 

(fig. 7):

.  Make sure the gas pressure is correct (see section 

about gas pressure, page 0).

.  Make sure the pilot burner has 3 flames.
3.  Make sure the flame is centred on the thermocouple.
4.  Make sure the thermocouple is enveloped by the flame 

up to at least 0mm (3/8”) from the tip (fig 0).

5.  Check the wires to the thermopile for cracks or dam-

age.

6.  Dismantle the wires from the vent.
7.  Dismantle optional equipment, such as thermostat or 

remote control.

Figure 27. Thermopile system check.

�����

�����

Содержание GF 400 CF

Страница 1: ...DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas sup plier from a neighbor s phone Follow the g...

Страница 2: ...n Company Date Service details Annual service year 5 Sign Company Date Service details Annual service year 6 Sign Company Date Service details Annual service year 7 Sign Company Date Service details A...

Страница 3: ...aller Information 6 5 User Information 12 6 Troubleshooting 14 THIS OWNER S MANUAL PROVIDES INFORMATION TO ENSURE SAFE INSTALLATION AND EFFICIENT DEPENDABLE OPERATION OF YOUR STOVE PLEASE READ THESE I...

Страница 4: ...p Flue Nett 77 9 78 2 Efficiency Class 2 2 NOx Class 4 5 Main Burner Injector Marking 33 51 Pilot Injector Marking 51 30 Notes The appliance is supplied at the default factory settings for Natural Gas...

Страница 5: ...intended for use on a gas installation with a governed gas supply Safety Precautions This appliance must be installed in accordance with the rules in force Consult instructions before installation and...

Страница 6: ...all not be put out of operation by the installer When the TTB is exchanged only original manufacturer s parts shall be used Installation Guide for Qualified Personnel Important The appliance is factor...

Страница 7: ...he appliance shuts off in operation for no apparent reason especially during windy or stormy conditions and will not relight it is possible that the flue system safety switch has operated Allow the ap...

Страница 8: ...ppliance and connect to the gas supply and carry out a smoke test on the flue as described in the relevant section of this manual Assembly Prior To Installation The product is delivered in 1 package I...

Страница 9: ...e embers realistically simulate glowing coals when the burner is operating These should be spread evenly over the burner plate and around the logs 1 Engage the holes in the underside 0f the Right Log...

Страница 10: ...awn into the flue and no smoke should spill into the room If the smoke does issue into the room leave for another 5 minutes and retest The appliance is fitted with a TTB flue sensing safety switch If...

Страница 11: ...this dimension is preset at the factory For Propane 18 5 mm must be set by installer CAUTION To avoid burns do not adjust the air shutter until the burner has cooled down Figure 22 Safety switch loca...

Страница 12: ...vide extra protection Operating Instructions Lighting Note Odors when using the stove When used for the first time the appliance may emit an irritating gas that may smell a little The gas is not toxic...

Страница 13: ...sing the stove for the first time Adjusting the Heat Setting Heat and flame size can be adjusted by turning the regu lator knob C marked HI LOW which is located next to the gas control knob see fig 23...

Страница 14: ...and when the valve is being replaced Troubleshooting When No Spark is Generated at the Pilot Head It is uncommon for the Piezo spark ignitor fig 25 A to fail unless it has mechanical damage If the spa...

Страница 15: ...for at least 30 seconds Make sure the flame is centred at the thermo couple Make sure the thermocouple is enveloped by the flame up to at least 3 mm 1 8 from the tip fig 20 If the flame is abnormally...

Страница 16: ...at there are 2 threaded holes fig 16 B and C that can be used when installing a new thermocouple Make sure the blue wire A is fastened at the same threaded hole The nut on the thermocouple must not be...

Страница 17: ...ral Gas Open 21 5 mm Warning To avoid burns do not adjust the air open ing until the burner has cooled down Blocked orifice Make sure the main orifice fig 28 is dirt free and that the orifice has the...

Страница 18: ...18 ONLY USE REPLACEMENT PARTS PROVIDED BY AN AU THORIZED J TUL DEALER Figure 29 J tul GF 400 CF Illustrated Parts Breakdown...

Страница 19: ...220641 Burner Orifice LP 1 70 mm 045027 38 Air Shutter 220790 39 Gasket 2 25 OD 118023 40 Wing Nut M6 117975 41 Washer 2 25 OD 220734 42 Screw 8 x 3 4 117986 43 Pilot Assembly NG 129471 44 Spacer Pil...

Страница 20: ...nformance with local and national building regulations Before beginning the installation it is important that the these instructions be carefully read and understood J tul maintains a policy of contin...

Отзывы: