6.  High Altitude Adjustment

The decreased atmospheric pressure of higher altitudes af-

fects heat value of gaseous fuels.  Most gas suppliers derate 

the gas intended for use at elevations above 2000 feet. 

Check with your gas supplier before performing derate 

adjustment to the burner.
This appliance may be adjusted for altitude over 2000 ft. 

(610 - 1371 m) for natural gas.  

If the gas supplier does not derate fuels, install High Alti-

tude Adjustment Kit 156822 for Natural gas.  

 

DO NOT DERATE FOR PROPANE.
U.S & Canada per 

ANSI Z21.88-2019•CSA 2.33-2019, CAN/CGA 2.17

For natural gas installations from 610-1370 meters 

(2000-4500 ft.) the orifice size (DMS) is #39.  See 

data plate for additional information. For high altitude 

installations consult the local gas distributor or the 

authority having jurisdiction for proper rating methods. 

If the installer must convert the unit to adjust for varying 

altitudes, the information sticker must be filled out and 

applied to the appliance at the time of the conversion. 

INSTALLER: Fill out the appropriate information and 

apply the high altitude conversion label provided to the 

rating plate on the appliance. See fig. 7.8.

Derating Procedure

•  Follow Steps 1-16 of the Fuel Conversion procedure on 

pages 16 to change the burner injector. Use the injec-

tor supplied with the kit.  Detailed instructions are also 

included in the kit.     

•  Conduct gas leak and gas pressure tests as detailed on 

page 15 of this manual.

•  Conduct system check and flame picture adjustments as 

specified on pages 21-22. 

Figure 7.8. High Altitude Conversion Label.

This appliance has been converted for use at an altitude 

of___________ .

Orifice Size: __________ Manifold Press. _______

Input Btu/Hr. _________  Fuel Type  ___________

Date: ___/___/___   Converted by:_____________

Cet appreeil a été converti au _____  Injecteur_____   

Pression à la tubulure d’alimentation ___________Déoit 

calorifique ___________

7.  Firebox Panel Installation

Skamol Panels and optional 

Reflective Glass Kit 156817

Skamol Panels

These insulating panels are installed at the factory. 

If 

desired, the panels may be painted black using any high-

temperature paint. 

THE SKAMOL PANELS MUST BE LEFT IN PLACE.  

DO NOT OPERATE THE STOVE WITHOUT THE SKA-

MOL PANELS INSTALLED.

Reflective Glass Panels

    

Tools:  1/4” socket driver

     Optional: High-temp Black Paint may be applied to the 

exposed edges of the side Skamol panels to match the black 

glass. 

Cotton gloves are provided with the glass panels. Use them 

to handle the panels to prevent fingerprints on the surfaces. 

Fingerprints are difficult to remove. Use a clean cloth to remove 

any dust from the glass panels.

1.  Remove the Upper Retainer Bracket from the firebox 

with removal of three #8 x 12 sheet metal screws.  See 

fig. 7.9. 

2.  Remove the Lower Panel Retainer from the back of the 

burner skirt with removal of three #8 x 12 sheet metal 

screws. 

3. 

Orient the rear panel, 

smooth side out, textured side 

in. 

Rest the bottom of the panel on the burner skirt, 

centered against the back wall. See fig. 7.10.  

4.  Orient the side panels, smooth side out, and sliding each 

behind the retainer wings.  See Fig. 7.11.

5.  Push the Upper Retainer back against the glass panels 

and tighten the three sheet metal screws.

6.  Replace the Lower Panel Retainer.

Содержание GF 370 DV MV

Страница 1: ...ll be installed in the same room as the appliance WARNING If the information in these instructions is not followed exactly a fire or explosion may result causing property damage personal injury or los...

Страница 2: ...rvice External regulator for Propane only Piping that complies with local code Manual shut off valve T Handle valve may be required in Massachusetts Sediment trap if required by code Tee joint Pipe wr...

Страница 3: ...9 12 Lighting Instructions 31 Unpacking the Stove 1 Before beginning the installation inspect the stove for shipping damage and immediately report any evidence of damage to your dealer 2 Confirm stove...

Страница 4: ...th America Gorham Maine USA J tul AS Fredrikstad Norway Test Standards This appliance complies with National Safety standards and is tested and listed by Intertek Testing Services of Middleton Wiscons...

Страница 5: ...cal codes This appliance is only for use with the type s of gas indicated on the rating plate This appliance is not convertible for use with other gases unless a certified kit is used 4 The installati...

Страница 6: ...appliance Clothing or other flammable materials should not be placed on or near the fireplace Never allow anyone to use the fireplace if they are unfamiliar with its operation NEVER store or use gaso...

Страница 7: ...S Comply with CSA Z240 4 Gas Equipped Recreational Vehicles and Mobile Housing in Canada 3 Always contact your local officials about installation restrictions and requirements in your area THIS APPLI...

Страница 8: ...imney components supplied by the following manufacturers M G DuraVent Inc Direct Vent Pro Series P O Box 1510 Vacaville CA 95696 1510 800 835 4429 Selkirk Corporation 1301 W President George Bush Hwy...

Страница 9: ...entsuppliers A maximum of two 90 or four 45 elbows may be used in a vertical termination Whenever possible use 45 elbows instead of 90 elbows as they offer less restriction to the flow of flue gases a...

Страница 10: ...0 square hole is adequate for proper pipe clearance through a wall provided the vent is positioned to maintain 2 minimum clearance at the top A 1 minimum clearance must be maintained to combustible ma...

Страница 11: ...onmechanical air supply inlet to building or the combustion air inlet to any other appliance 12 in 30 cm 9 in 23 cm K Clearance to a mechanical air supply inlet 6 ft 1 83 m 3 ft 91 cm above if within...

Страница 12: ...adjustments 3 Tighten the locking screw and replace the Trim Rings Vent Restriction Adjustments The J tul GF 370 DV MV features adjustment controls for both intake air and exhaust to accommodate a va...

Страница 13: ...these offer less restriction to the flow of flue gases and intake air Reduce the overall horizontal run by 5 feet for each additional 45 and 90 elbow When two or more elbows are used in a horizontal...

Страница 14: ...MASSACHUSETTS The stove and gas control valve must be disconnected from the gas supply piping during any pressure testing of the system at test pressures in excess of 1 2 psig For pressures lower tha...

Страница 15: ...g 7 3 Gauge connections are identified by E for inlet or supply pressure the amount of gas com ing to the valve A for manifold pressure the amount of gas that is com ing out of the valve to the burner...

Страница 16: ...nd wrench or deep well socket to remove the burner orifice from the brass orifice holder Replace with the orifice supplied in the kit CAUTION Do NOT over tighten the Burner Injector Over tightening ca...

Страница 17: ...dentificationlabelstothestovesothattheycanbeseen byanypersonthatmaybeservicingthestove Label A Applytofrontlipofthevalvecompartment Label B Apply to the Rating Plate Small valve sticker Apply to valve...

Страница 18: ...d on pages 21 22 Figure 7 8 High Altitude Conversion Label This appliance has been converted for use at an altitude of___________ Orifice Size __________ Manifold Press _______ Input Btu Hr _________...

Страница 19: ...pilot ignition See figs 7 16 and 10 3 for examples StarFire Glass Embers Do not use more than the four pounds in two 2 lb bags of glass media provided For best results evenly spread the contents of th...

Страница 20: ...Lean the Right Log up against the upper right corner of the firebox and engage the slot on the tip with the pin on the Bottom Log Figure 7 16 Evenly disperse the Ember Stones over the burner plate ar...

Страница 21: ...bottom of Rear Log 2 with the two steel pins B at the left rear corner of the burner plate 5 Engage the two holes in the bottom of the Center Log 3 with the two burner plate pins C 6 Engage the holes...

Страница 22: ...monia based glass cleaner 2 Hold the glass frame to firebox front with holes in align ment where socket head screws were removed 3 Replace the socket head screws into glass frame finger tight Readjust...

Страница 23: ...oting in the Ceramic Burner Guide if greater than 4 seconds Reinstall the glass frame prior to hot start testing C Hot Start After the burner has been on for 5 10 minutes turn it off and wait 2 minute...

Страница 24: ...source for the thermostat At the thermostat the two wires should be connected to the two connection screws on the thermostat base plate per the manufacturer s instructions CAUTION LABEL ALL WIRES PRIO...

Страница 25: ...and the area under the appliance free of dust Always keep the appliance area clear and free from combustible materials gasoline and other flammable liquids 4 This appliance is operated with a continu...

Страница 26: ...e assembly upside down on a flat surface protecting the frame from scratches using a blanket or towel 3 The glass panel is held in place by four retainer tabs Use a screwdriver to carefully pry these...

Страница 27: ...er GF 370 MB 38 225402 Outer Rod Exhaust Restrictor 39 223224 Skamol Rear Panel 40 223235 Skamol Side Panel 2 not illustrated No Part Number Description 1 9911 Bolt Hex Cap M6x45 DIN 933 Class 8 8 Blk...

Страница 28: ...or Catch GF 370 Matte Black 21 156843 Lower Door Hinge Asy GF 370 MB 22 156835 Replacement Outer Side Glass GF 370 25 223220 Plate Centering GF 370 Figure 11 2 External parts identification 27 2255849...

Страница 29: ...29 130102 1 GF 370 DV MV 2 22 Figure 11 3 GF 370 DV MV Spud assembly parts identification...

Страница 30: ...lock 25 117922 Nut Hex M4 DIN 934 Plain 26 3902576 Igniter Bracket 27 3902573 Piezo Ignitor Button 28 117920 Screw Pan Head Phillips M4 X 8 29 224799 Switch Plate GF 373 30 225631 Valve Bracket GF 373...

Страница 31: ...31 130102 1 GF 370 DV MV 2 22 This Page is intentionally left blank...

Страница 32: ...32 130102 1 GF 370 DV MV 2 22 This Page is intentionally left blank...

Страница 33: ...ge due to incorrect installations not in conformance with the installation instructions contained in this owner s manual or local and or national fire and building regulations 3 Damage due to service...

Страница 34: ...________________________ PHONE ____________________________________ INSTALLER __________________________________ FUEL TYPE ____________________________________ FUEL CONVERSION NO _______ YES_____ NOTE...

Страница 35: ...INSTRUCTIONS WARNING IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE PERSONAL INJURY OR LOSS OF LIFE A This appliance has a pilot which must be l...

Страница 36: ...s appliance must be installed in conformance with local and national building regulations Before beginning the installation it is important that the these instructions be carefully read and understood...

Отзывы: