INSTALLATION INSTRUCTIONS 

5. Slide the coil on to the valve shaft and replace 
the top nut. Tighten the top nut (max. torque 
1Nm) using a 14 mm wrench. 
 

 

The coil can be rotated 360° around the valve, 
you can align the coil as desired.

 

6. Place the flat gasket over the coil 
connection pins.  

       

 

 

Make sure there is no debris between the 
gasket and the coil. 

7. Mount the timer on to the coil as illustrated 

below. 

 

             

  

8. Remove the protection cap from the 
connector and connect your power cable 
to the connector

 

as shown below. 

 

  

      

 

9. Place the connector gasket on the connector, 
plug the connector on the timer as illustrated 
below and tighten the screw (max. torque 1Nm) 
and make sure both gaskets are secured 
properly to ensure IP65 rating. 
 

   

   

 

 

10. After double checking that the power 
supply corresponds with the voltage specified 
on the coil, you can switch it on. 

 

       

 

            

 

 L 

Содержание TEC-11

Страница 1: ...e TEC 11 removes condensate automatically from compressed air filters and i e small dental compressors The TEC 11 is designed for ALL compressed air filters regardless of their capacity or size The TE...

Страница 2: ...fe working practices and observe all regulations and legal requirements for safety when operating this product When handling operating or carrying out maintenance on this product personnel must employ...

Страница 3: ...3 EXPLODED VIEW IDENTIFY ALL COMPONENTS DIAGRAM Top nut Coil Flat gasket TEC 11 timer Connector gasket Connector Screw Shaft Spring Plunger Body...

Страница 4: ...ed out 3 The drain is shipped fully assembled Disassemble the drain before installation by unscrewing the screw in the connector and the top nut above the coil see page 3 for an exploded view 4 Locate...

Страница 5: ...the gasket and the coil 7 Mount the timer on to the coil as illustrated below 8 Remove the protection cap from the connector and connect your power cable to the connector as shown below 9 Place the c...

Страница 6: ...lve function 14 Adjust the OFF button to suit your system i e 20 min 13 The drain is now at full system pressure and will periodically discharge any condensate it receives from your compressed air sys...

Страница 7: ...out 1 Close the condensate supply i e close the ball valve in front of the filter 2 Press the TEST button to empty the unit of any residual condensate and to depressurise the TEC 11 valve 3 Switch off...

Страница 8: ...ing a 13 mm wrench 10 Swith on the electrical supply 9 Reposition the coil timer and connector assembly on to the valve replace the top nut and tighten the top nut max torque 1Nm using a 14 mm wrench...

Страница 9: ...9 SERVICE CHART Date Description Name...

Страница 10: ...on DIN 43650B ISO 6952 Indicators Yellow LED s indicating on off Valve type 2 2 Way direct acting valve Connections 1 8 or 1 4 BSP or NPT Max Pressure 0 16 BAR 21 bar optional Operating Temperature 2...

Отзывы: