background image

 

 

INSTALLATION INSTRUCTIONS

 

 

 
 

 

IMPORTANT NOTICE

 

 

Before installing this product, make sure it 

complies with your request and that it suits 

your application! 

1. Unpack the unit and visually inspect for any  
transport damage incurred after leaving our 
factory.

 

        

 

                                                 

 

                  2. Depressurise the system before installation or maintenance is carried out! 

3. The drain is shipped fully assembled! 
Disassemble the drain before installation by 
unscrewing the screw in the connector and the 
top nut above the coil (see page 3 for an 
exploded view).

 

 

 

 

4.

  

Locate a suitable condensate draining point 

on your compressor system and connect your 
valve as illustrated below. Connect the outlet to 
an oil/ water separator. We recommend using a 
JORC condensate cleaner. 

 

               

 

 

 

-

 

Make sure the arrow on the valve body 
complies with the flow direction of the 
condensate.  

-

 

Do not use valve shaft as lever! 

 

Содержание TEC-11

Страница 1: ...e TEC 11 removes condensate automatically from compressed air filters and i e small dental compressors The TEC 11 is designed for ALL compressed air filters regardless of their capacity or size The TE...

Страница 2: ...fe working practices and observe all regulations and legal requirements for safety when operating this product When handling operating or carrying out maintenance on this product personnel must employ...

Страница 3: ...3 EXPLODED VIEW IDENTIFY ALL COMPONENTS DIAGRAM Top nut Coil Flat gasket TEC 11 timer Connector gasket Connector Screw Shaft Spring Plunger Body...

Страница 4: ...ed out 3 The drain is shipped fully assembled Disassemble the drain before installation by unscrewing the screw in the connector and the top nut above the coil see page 3 for an exploded view 4 Locate...

Страница 5: ...the gasket and the coil 7 Mount the timer on to the coil as illustrated below 8 Remove the protection cap from the connector and connect your power cable to the connector as shown below 9 Place the c...

Страница 6: ...lve function 14 Adjust the OFF button to suit your system i e 20 min 13 The drain is now at full system pressure and will periodically discharge any condensate it receives from your compressed air sys...

Страница 7: ...out 1 Close the condensate supply i e close the ball valve in front of the filter 2 Press the TEST button to empty the unit of any residual condensate and to depressurise the TEC 11 valve 3 Switch off...

Страница 8: ...ing a 13 mm wrench 10 Swith on the electrical supply 9 Reposition the coil timer and connector assembly on to the valve replace the top nut and tighten the top nut max torque 1Nm using a 14 mm wrench...

Страница 9: ...9 SERVICE CHART Date Description Name...

Страница 10: ...on DIN 43650B ISO 6952 Indicators Yellow LED s indicating on off Valve type 2 2 Way direct acting valve Connections 1 8 or 1 4 BSP or NPT Max Pressure 0 16 BAR 21 bar optional Operating Temperature 2...

Отзывы: