background image

Please read the instructions fully

before attempting installation.

IMPORTANT

This unit should be installed to current

IEE wiring regulations if in doubt

consult a qualified electrician.

Timer must not be mounted on a

flammable surface.

Ensure that the timer does not come

into contact with any combustible

materials such as towels or bedding.

Ensure at least a

300

mm air space

is allowed around the timer.

INSTALLATION /OPERATING

INSTRUCTIONS FOR

24

HOUR

MECHANICAL IMMERSION

HEATER TIMER - T

102

-C

WIRING THE TIMER

Drill two

6

mm holes

97

mm vertically

apart in the wall. Insert plastic anchor

(supplied) into holes and fit one No.

6

screw to top hole leaving a gap under

the screw head of approximately

4.75

mm.

Place the keyhole slot over the screw and

slide the timer down; if the timer is loose

remove it, tighten the screw and refit the

timer. Continue to do this until the timer

fits securely against the wall. Remove

terminal cover “D” by undoing screw

“C”. lnsert the second No.

6

screw into

slot “B ” and tighten. Your timer is now

ready for wiring.

FIXING THE TIMER

TO THE WALL

Prepare cables for connection to the

timer, (see Diagram A).

The maximum size cable that can be

used with this timer is

2.5

mm. If flat

twin and earth cable is used the bare

earth cable must be fitted with

green/yellow sleeving before fitting

the earth terminal.

Fit the bare wire ends into the correct

terminals (see diagram B). You must

ensure that there are no loose strands

left out of the terminals.

Firmly tighten all the screws.

Using the cable clamps and screws

provided and ensuring the cable

clamp is fitted the correct way round,

tightly secure the cable into position.

Ensure the correct cable cut-outs have

been removed in terminal cover “D”

and refit terminal cover “D ” and

tighten screw “C”.

N.B. Check all terminal screws are tight.

Your kingshield timer should be wired

from a fused spur. We recommend a

PowerBreaker H

92

RCD model.

Switch off the mains and isolate

the supply by removing the appropriate

fuse before starting the installation.

B

C

Red or Brown

Black or Blue

Green or yellow

Diagram A

D

Diagram B

From mains

L

= Red or Brown

N = Black or Blue

= Green or Yellow

To appliance

Reviews: