60
- 76
minimate
plus
43
44
45
3mm
Fig. 43: Clean the glass using a damp
cloth.
Do not use liquid cleaners,
sprays, soap or other
products.
The presence of a whitish layer on the perforated metal sheet inside the glass indicates
the need to replace the pipe. The tube must usually be replaced within 18 months of
use.
Fig. 44: Wash the mesh under running
hot water and dry it thoroughly with a
non-fraying cloth.
Fig. 45: Put the outer metal mesh
back on the glass tube so that it fully
overlaps the internal plate.
Do not put back the mesh
on the ionising tube if it is
even partially wet.
In any case ensure a
minimum distance of at
least 3 mm from the base
of the tube.