background image

13

 - 76

minimate

 plus

The device 

JO

NIX minimate

 plus

 is equipped with two filtration stages. The medium filter 

F7 combined with the absolute filter H13 or H14 allow the reduction of airborne fine dusts and to 
ensure a very high degree of filtration.
The device involves the use of non-thermal plasma technology for air sanitization out of the 
device. In this way the ionizing charge developed allows the maximum sanitizing and purifying 
action of the ambient air.
The 

JO

NIX minimate

 plus

 also combines filtration with non-thermal plasma technology for 

sanitisation of the internal components of devices.

The activity of air purification and sanitisation of the internal components of the 

JO

NIX 

minimate

 plus

 device is compatible with the presence of persons and animals.  No chemicals 

are used and no harmful residual substances are generated.

Содержание minimate plus

Страница 1: ...minimate plus USE AND MAINTENANCE MANUAL AIR PURIFICATION AND AIR SANITIZATION DEVICE ACTIVE SANITISATION OF INTERNAL COMPONENTS WITH ADVANCED COLD PLASMA TECHNOLOGY...

Страница 2: ...ages that do not conform to the original meaning JONIX S p A reserves every right concerning this manual including the right to make any necessary change or improvement to its products and to the manu...

Страница 3: ...NDLING AND TRANSPORT 17 5 3 INSPECTION UPON RECEPTION 17 5 4 STORAGE 17 6 INSTALLATION AND COMMISSIONING 18 6 1 SAFETY INSTRUCTIONS 18 6 2 GETTING STARTED 20 6 3 OPERATING SITE CHARACTERISTICS 24 6 3...

Страница 4: ...ny complaints must be submitted in writing within 8 days of receiving the goods 6 8 9 5 Accessing the time slots 40 6 8 9 5 1 Time slots 41 6 8 9 6 Recording of maintenance 42 6 8 9 6 1 Air ionizers m...

Страница 5: ...http www jonixair com In particular if the maintenance of the device is carried out in a manner that does not comply with the instructions provided or in any case in such a way as to compromise its in...

Страница 6: ...RNING It refers to integrations or suggestions concerning the proper use of the device HAZARD It refers to dangerous situations that may result from the use of the device in order to ensure personal s...

Страница 7: ...re able to assess the work entrusted to them and recognize and avoid any hazards AUTHORIZED PERSONNEL Specialised personnel assigned by the user to carry out certain tasks HAZARD Source of possible in...

Страница 8: ...any damage caused This Use and Maintenance Manual is an integral part of the device and must therefore be kept with care and must ALWAYS accompany the device even if it is transferred to another owner...

Страница 9: ...tion before disconnecting the device from the power supply is prohibited Do not touch the device if you are barefoot and with parts of the body that are wet or damp Cleaning and maintenance intended t...

Страница 10: ...he power supply to the device and consult your dealer and or JONIX S p A Only trained and qualified personnel can perform maintenance operations other than those specified in this manual ATTENTION BEF...

Страница 11: ...L OBLIGATION TO DISCONNECT VOLTAGE BEFORE MAINTENANCE OBLIGATORY USE OF PROTECTIVE GLOVES MOVING PARTS HAZARD 2 1 SAFETY SIGNS Check the condition of the safety pictograms periodically and replace the...

Страница 12: ...tizing device exploiting the physical phenomenon of ionization promotes the controlled formation of particular electrically charged species in the air through an electrostatic field The latter simulat...

Страница 13: ...nitization out of the device In this way the ionizing charge developed allows the maximum sanitizing and purifying action of the ambient air The JONIX minimate plus also combines filtration with non t...

Страница 14: ...intenance access door 9 Filter fixing brackets 10 Magnetothermic switches for fan power supply disconnection Q1 and auxiliary power supply disconnection Q2 11 Access door opening switch button for mai...

Страница 15: ...00006 F7 Filter JX70000016 H13 Filter For product with code 70MMBASICF H13 JX70000017 H14 Filter For product with code 70MMBASICF H14 70CONDTIPO175 175 IONISING PIPE REPLACEMENT No 1 175 ionising pipe...

Страница 16: ...requirements are supplied with suitable enclosure secured to the inside or outside of the device itself The package includes JONIX minimate plus no 1 ionising pipe for sanitisation of the internal el...

Страница 17: ...evers grappling hooks without ever using hands alone During lifting and or transport and or handling operations provide for appropriate signalling and confinement of the dangerous zone signalling the...

Страница 18: ...ls and restarting the device Comply with the laws in force in the country in which the device is installed regarding the use and disposal of the packaging and products used for cleaning and servicing...

Страница 19: ...n front of cracks and openings as indicated in this manual Do not pull the power cord and make sure it is not too taut when connecting the device Keep the cord and device away from hot surfaces Do not...

Страница 20: ...must be kept by the user and if necessary given only to authorised users 6 2 GETTING STARTED ATTENTION Any use other than that specified herein shall be deemed to be incorrect Disconnect the device fr...

Страница 21: ...s of ionizing tubes Fig 5 Take the power cord and the ionising pipes Handle the ionising pipe carefully as it is fragile To simplify operations it is advisable to start with the tube in the plus posit...

Страница 22: ...sing tubes have been screwed back into place Otherwise contact the manufacturer ATTENTION do not overtighten the screw after reaching its end stop Fig 8 Put back the upper filter making sure the gaske...

Страница 23: ...e tube Check that the earthing spring is in contact with the outer mesh once the ionising tubes have been screwed back into place Otherwise contact the manufacturer ATTENTION do not overtighten the sc...

Страница 24: ...resence of electrical and electronic equipment not specially designed Do not place the device in environments where there are flammable gases acidic aggressive and corrosive substances that could dama...

Страница 25: ...equipped with Do not move the device by pulling the power cord Turn off and unplug the device before moving it Do not operate the device if there are no wheels 6 3 1 Position of the operator During o...

Страница 26: ...of the device may result in damage to the device or some of its parts 6 5 ELECTRIC POWER SUPPLY 6 6 USING THE DEVICE The JONIX minimate plus device is ready for connection to the civil power supply ne...

Страница 27: ...on 1200 4 The device is set with the following default parameters 6 7 1 First start checks At first start up the device should be subjected to at least the following checks check the integrity and sta...

Страница 28: ...f every single component in a more detailed way and its own personalization as needed In the main screen are reported this information a Ionizers allows access to the ionizers menu b Filters allows ac...

Страница 29: ...OL The device is switched ON The device is switched ON according to the setting of the time slots The device will turn off when requested by setting the time slots The device is switched OFF The devic...

Страница 30: ...the window Warning The machine is not operating because Turned Off from door switch Push the Cancel button to close the window TURN ON CANCEL CANCEL CANCEL CANCEL To reactivate the device activate it...

Страница 31: ...ding message appears Repeat the operation entering the correct password On the main screen the upper left symbol marked with f is used to intuitively identify the status of the device as indicated in...

Страница 32: ...is entered the USER LOGIN lasts 10 minutes Once this time has elapsed the device will ask for the password again to proceed with the settings or will automatically perform the USER LOGOUT To perform t...

Страница 33: ...placement operation cleaning or replacement of the corresponding ionizing modules was recorded d Working hours total hours of ionising pipe activity since the last recorded maintenance gods correspond...

Страница 34: ...ion hours remaining hours to replace the ionising pipe e to return to the previous screen b Sanitation cycle activation time the factory setting is 22 00 press the time to open the dialogue box and ch...

Страница 35: ...rop of the corresponding filter Once the 100 is reached the filter replacement becomes necessary ATTENTION this number could not be equal to zero even when the filter is new d Air volume treated m3 to...

Страница 36: ...Pressure drop it is the real time measurement of the pressure drop on the fan d to return to the main screen Shows a more detailed fan status and allows the management of its operation status as need...

Страница 37: ...n press the settings logo to navigate through the modifiable data menus Press the info logo to access the information screen In each screen it is possible to view the technical information of the devi...

Страница 38: ...Date b Month c Year d Hour e Minutes Save the settings by pressing The white icon shows which language is used in that moment Press another key to change it IT Italiano EN English FR Fran ais DE Deuts...

Страница 39: ...t the authorizations management to check the device On the settings screen press the logo to navigate in the corresponding menu and manage the authorisations and the password of the device Numerical k...

Страница 40: ...ations without the need for USER LOGIN paragraph 6 8 4 User login user logout d Password is always required USER LOGIN required to perform all actions that change the status of the device paragraph 6...

Страница 41: ...ave button it appears when any change is made to one of the time slots Press the key to store the changes When the saving operation is successfully finished the button disappears The setting of the st...

Страница 42: ...ion must be repeated NOTE it is always necessary to save before changing the day or leave the menu If not the modification will be lost If only one time slot is set or enabled the device will operate...

Страница 43: ...nce procedures are explained in the chapter 7 Maintenance of this manual a Cleaning records the cleaning operation b Replacement records the replacement operation c to return to the maintenance screen...

Страница 44: ...intervention The maintenance procedures are explained in the chapter 7 Maintenance of this manual a Cleaning records the cleaning operation b Replacement records the replacement operation c to return...

Страница 45: ...e record by the system of the maintenance operation that was done will appear Press YES to confirm or NO to cancel Save the filter maintenance date By pressing one of the keys Pressing it is possible...

Страница 46: ...On the settings screen press the logo to view the history of alarm messages a Set the desired time interval to view the alarms On the settings screen press the logo to navigate in the corresponding m...

Страница 47: ...6 8 6 Filter ionising module screen At the set time the ionisation cycle of the filter starts 1 the fan stops for 29 minutes the symbol remains present but static and the ioniser starts working 2 the...

Страница 48: ...he report Filter alarm Filters Fan Fan alarm Ioniser Ioniser alarm Alarm signalling power supply voltage outside the rated range which could damage the ioniser Ioniser On the main screen notifications...

Страница 49: ...es for sanitization of the air AL12 Replacement of ionizer module B See par 7 2 4 1 replacement of the ionizing tubes for the air sanitation AL13 Replacement of ionizer module A See par 7 2 4 1 replac...

Страница 50: ...plasma generator ionising pipe The JONIX minimate plus device signals the need to perform maintenance on the non thermal plasma generators through an alarm viewed on the display paragraph 6 8 11 Alar...

Страница 51: ...notified on the display The device JONIX minimate plus indicates the need to replace the filters with the icon on the main screen ATTENTION When servicing the filters pay particular attention to your...

Страница 52: ...Push the filter locking tabs inwards until they click Fig 22 Close the front maintenance access panel with the appropriate keys Make sure the rubber seal of the filter is facing down Check that the m...

Страница 53: ...erceived Pay particular attention to the air passage grilles check that they are clean to ensure the passage of air Record the maintenance operation performed using the display as described in paragra...

Страница 54: ...hours of operation Clean the ionising tube every time it is shown on the display The device JONIX minimate plus indicates the need for maintenance on the ionising pipe with the icon on the main scree...

Страница 55: ...be If this is difficult to do turn the mesh around the glass while pulling to remove it Fig 30 Clean the glass using a damp cloth Do not use liquid cleaners sprays soap or other products Check that th...

Страница 56: ...ce of at least 3 mm from the base of the tube Check that the earthing spring is in contact with the outer mesh once the ionising tubes have been screwed back into place Otherwise contact the manufactu...

Страница 57: ...1 and for disconnection of the auxiliary power supply Q2 are in the ON position Fig 34 Put back the upper filter making sure the gasket in tire is facing down Fig 36 Close the front maintenance access...

Страница 58: ...d the maintenance operation performed using the display as described in paragraph 6 8 9 6 Recording of maintenance Reset the alarm launched by the device in the alarm screen Fig 38 Switch the device o...

Страница 59: ...rt If the operation is difficult to perform pull slightly the earthing spring so that it is not in contact with the surface of the tube Fig 42 Pull off the outer mesh from the tube If this is difficul...

Страница 60: ...ed to replace the pipe The tube must usually be replaced within 18 months of use Fig 44 Wash the mesh under running hot water and dry it thoroughly with a non fraying cloth Fig 45 Put the outer metal...

Страница 61: ...thing spring is in contact with the outer mesh once the ionising tubes have been screwed back into place Otherwise contact the manufacturer ATTENTION do not overtighten the screw after reaching its en...

Страница 62: ...ing from the ionising pipe and the air flow generated by the fan will be perceived Should a malfunction persist unplug the device from the mains and contact qualified staff Failure to clean the ionisi...

Страница 63: ...component They are evident with the appearance of oxide in the condenser internal mesh that will make it whitish and that will render the glass opaque The JONIX minimate plus signal the need of repla...

Страница 64: ...sing pipe holding on to the base green part If the operation is difficult to perform pull slightly the earthing spring so that it is not in contact with the surface of the tube Check that the earthing...

Страница 65: ...ry power supply Q2 are in the ON position Fig 58 Close the front maintenance access panel with the maintenance access key Fig 59 Connect the power plug to the mains Turn on the device using the light...

Страница 66: ...ing of maintenance Reset the alarm launched by the device in the alarm screen Fig 60 Switch the device off by turning the switch Remove the plug connected to the mains Fig 61 Open the front maintenanc...

Страница 67: ...do not overtighten the screw after reaching its end stop Fig 63 Gently unscrew the ionising pipe gripping it at the base green part If the operation is difficult to perform pull slightly the earthing...

Страница 68: ...k that the magnetothermic switches for disconnection of the fan power supply Q1 and for disconnection of the auxiliary power supply Q2 are in the ON position Fig 67 Close the front maintenance access...

Страница 69: ...ionising pipe when indicated by the device will result in a reduction in system performance Record the maintenance operation performed using the display as described in paragraph 6 8 9 6 Recording of...

Страница 70: ...ionising pipe is faulty Contact a maintenance technician authorised by the manufacturer Maintenance required on the ionising pipe Follow the instructions in section 7 2 ROUTINE MAINTENANCE There is n...

Страница 71: ...GENERAL DIAGNOSTIC PROVISIONS Fig 69 Disconnect the power supply to the device and contact JONIX S p A or a dealer for assistance also when the power cord is damaged or deteriorated the power plug is...

Страница 72: ...left in the environment it has a negative impact on the ecosystem Read the instructions carefully before using the unit for the first time It is recommended that the product should not be used for an...

Страница 73: ...Union applicable Es conforme con las pertinentes disposiciones de las directivas comunitarias 2006 42 CE 2014 30 UE 2011 65 UE 2012 19 UE Riferimento alle norme armonizzate che sono state applicate R...

Страница 74: ...74 76 minimate plus NOTES...

Страница 75: ......

Страница 76: ...Fax 39 049 9588522 Operational Headquarters Via dell Artigianato 1 35020 San Pietro Viminario PD Italy Ph 39 0429 760311 ResearchandDevelopment Headquarters Via Tegulaia 10 b 56121 Pisa Italy Ph 39 0...

Отзывы: