7.2.1  Cleaning the Ionising Tubes

Fig. 03: Switch off the ionising module 

JO

NIX

 

duct

 by turning the luminous On/

Off switch to   O.
Remove the plug connected to the mains 
and other plugs from the 

JO

NIX

 

duct 

module.

Fig. 04: Unscrew the four screws which, by 
means of the brackets, secure the module 
to the wall and pull it out by the handle.

Fig. 05:  Gently unscrew the tubes, using 
the green plastic base
. If you have trouble, 
first pull off the outer mesh.

Fig. 06:  Pull off the outer mesh from the 
tube if you have not already done so in the 
previous point. 

Clean the glass using a damp cloth.

If the operation is difficult 
to perform, pull slightly the 
earthing spring so that it is not 
in contact with the surface of 
the tube.

If this is difficult to do, turn the 
mesh around the glass while 
pulling to remove it.

Check that the tube is in good conditions: there must not be any cracks or other damage; 
otherwise it must be replaced. As soon as you notice a whitish layer on the perforated 
metal plate inside the glass it means that the ionising tube needs replacing.
The tubes must usually be replaced within 18 months of use.

Содержание duct 70MIC2C

Страница 1: ...MADE IN ITALY JONIX duct JONIX duct 70MIC4F JONIX duct 70MIC2F JONIX duct 70MIC4C JONIX duct 70MIC2C DUCTABLE IONISING MODULE USE AND MAINTENANCE MANUAL...

Страница 2: ...IX S p A reserves every right concerning this manual including the right to make any necessary change or improvement to its products and to the manual at any time and without notice It is forbidden to...

Страница 3: ...10 5 4 STORAGE 10 5 5 HANDLING DEVICE IN OPERATING CONDITIONS 10 6 INSTALLATION AND COMMISSIONING 11 6 1 SAFETY STANDARDS 11 6 2 GETTING STARTED 12 6 3 CHOOSING THE INSTALLATION SITE 12 6 4 INSTALLIN...

Страница 4: ...ct damage caused by incorrect installation or damage caused by the units installed by inexperienced and or unauthorised staff At the time of purchase check that the device is intact and complete The M...

Страница 5: ...orbidden to use the device in environments where the air is mixed with and or altered by other gaseous compounds and or solid particles Using the device for purposes other than those intended and that...

Страница 6: ...ny that sold you the device 2 WARNINGS AND GENERAL PROHIBITIONS HAZARD It refers to dangerous situations that may result from the use of the device in order to ensure personal safety WARNING It refers...

Страница 7: ...the device Please note that the use of products that require electricity involves the observance of some crucial safety rules such as When installing commissioning and operating this product it is ma...

Страница 8: ...of JONIX duct are High efficiency reduction of bioburden and of volatile organic compounds up to 99 compared to the initial concentration Low power consumption from 20 to 40 VA Strong deodorizing act...

Страница 9: ...arious models can be assembled in group of the same type or comined according to the airflow to deal with Mod Article Dimensions LxPxH mm Power Supply Plasma generators Max sprayed airflow m3 h Max po...

Страница 10: ...by filling in the relevant section on the delivery note and specifying the type of damage 5 3 INSPECTION UPON RECEPTION The Manufacturer disclaims any liability for damage due to incorrect unloading f...

Страница 11: ...egrity of the various components and of the electrical mains to which it is connected making sure that it is fitted with a circuit breaker upstream of the power line as shown in this manual Never inse...

Страница 12: ...ontained in this manual Never force the components when assembling although it is made with high strength materials the parts of the device can be damaged if handled incorrectly Do not try to perform...

Страница 13: ...ductwork and with any material JONIX duct devices thanks to their adaptability and to their space saving designs can be easily fixed on either side of the duct All you need is an opening on a wall in...

Страница 14: ...TENTION BEFORE STARTING ANY OPERATION MAKE SURE THAT THE MAIN POWER SUPPLY IS DISCONNECTED The JONIX duct device leaves the factory fully wired It only needs to be plugged into the electric mains 230V...

Страница 15: ...end you to link the contact of input signal and serial interface RS485 JONIX duct devices are made up of electronic control enclosed in an insulating shell and of actuators the ionising unity are expo...

Страница 16: ...is enabled after 7000 hours of functioning to indicate the necessity of a periodic cleaning of plasma generators flashing way 5 sec on 2 sec off or after 14000 hours to ask the sostitution of generat...

Страница 17: ...abled 1 enabled Lecture Scripture 18 Pilotage Modbus On Off 0 not active ionisation 1 active ionisation Lecture Scripture 19 Manual threshold for MAX voltage alarm generators cV Lecture Scripture 20 T...

Страница 18: ...unt of maintenance consisting in regularly cleaning the glass and outside mesh of the condenser The device signals the need for maintenance of the generators by means of a special alarm contact every...

Страница 19: ...sh Fig 06 Pull off the outer mesh from the tube if you have not already done so in the previous point Clean the glass using a damp cloth If the operation is difficult to perform pull slightly the eart...

Страница 20: ...nsure a minimum distance of at least 3 mm from the base of the tube Fig 09 Gently screw the ionising tube holding on to the base green part If the operation is difficult to perform pull slightly the e...

Страница 21: ...the appropiate sockets of the JONIX duct module Switch on the moduleby turning the On Off switch to I Verify the functioning of the device it has to be hear a light sizzle coming from the tubes Reset...

Страница 22: ...s of operation 7 3 SPECIAL MAINTENANCE 7 2 1 Replacing the Ionising Tubes Fig 12 Switch off the ionising module JONIX duct by turning the luminous On Off switch to O Remove the plug connected to the m...

Страница 23: ...eposition the device JONIX duct by inserting the ionising tubes horizontally into the specific hole using the handle and screw in the 4 screws which secure the brackets to the wall Fig 17 Reinsert the...

Страница 24: ...e device is connected works Verify the presence of power in distribution system Verify that the protection fuse isn t burnt The alarm contact 1 notes the presence of a malfunctioning and the spy is on...

Страница 25: ...ough your municipal authorities as to the location of the eco friendly waste management sites where waste can be received for disposal and its subsequent recycling as recommended Furthermore please no...

Страница 26: ...26 JONIXduct 119 173 76 350 255 196 190 160 90 90 285 9 9 37 5 121 37 5 40 120 ATTACHMENTS OVERALL DIMENSIONS JONIX duct 70MIC2C...

Страница 27: ...35 36 35 350 74 5 74 5 160 190 196 119 173 9 9 37 5 121 37 5 40 120 285 255 OVERALL DIMENSIONS JONIX duct 70MIC4C...

Страница 28: ...28 JONIXduct 119 173 76 255 196 161 90 90 285 534 9 9 37 5 121 37 5 698 40 120 OVERALL DIMENSIONS JONIX duct 70MIC2F...

Страница 29: ...29 JONIXduct 196 255 285 74 5 35 36 35 74 5 160 535 119 173 9 9 121 695 40 120 37 5 37 5 OVERALL DIMENSIONS JONIX duct 70MIC4F...

Страница 30: ...30 JONIXduct NOTES...

Страница 31: ......

Страница 32: ...ters info jonixair com Certified mail jonixsrl legalmail it web www jonixair com Via Tegulaia 10 b 56121 Pisa Italy tel 39 050 985165 Via dell Artigianato 1 35020 San Pietro Viminario PD Italy Tel 39...

Отзывы: