b) BASIC KIT configuration for closed vessel installation (optional kit)
The representation of the components is approximate, but they can change in terms of shape.
NOTE
1-1.2 bar cold pressurised water must always be in the device.
The expansion tank not supplied must be sized by the installer/designer.
Install the pressure transducer on the flow or return of the fireplace.
Topping up pressure is not automatic.
It is mandatory to always leave the cold water inlet of the cooling coil water open and the pressure upstream of the heat
discharge valve must be at least 1.5 bar.
WARNING
1. Inlet heat discharge valve (cooling coil cold water
inlet) (3/4” M)
2. Hot water safety heat discharge (3/4” M)
3. Safety temperature probe well of the heat discharge
valve (1/2” F)
4. Water inlet for system loading (1/2” F)
5. Temperature probe well (1/2” F)
6.
System flow (1” M)
7. 2.5 bar safety valve (1/2” F)
8. System return (1” M)
1
2 3
4
5
6
7
8
1
2 3
4
5 6 7 8