background image

ENGLISH

 

06.2 

RECOMMENDED FUELS

WOOD COMBUSTION

Wood clean burning is a process that reflects the natural decomposition itself; this means that CO

2

 (carbon dioxide) 

released does not increase or damage the CO

2

 original contents in the atmosphere.

The basic prerequisites for clean combustion are:

1.

 

Using dry and untreated wood

2.

 

Using the correct size and quantity of combustible: too little firewood or logs too large impede the fireplace to reach 

the optimum operating temperature.

KINDS OF WOOD

Each type of wood is characterized by its own density (weight related to the volume) and from different calorific values 

(related to the mass and moisture present). We can identify two broad categories: hardwoods and softwoods.

Hardwoods, usually deciduous woods, are the most dense ones, weigh heavily and contain very little resin, burn slowly and 

are the best materials in providing long ranges of combustion.

Softwoods, such as conifers, have a lower density, produce a strong warm but burn much more quickly; so they are better 

advised for starting combustion; if used as main combustible it would be necessary to load the fireplace more frequently; 

furthermore their high resin contents bring to more dirt, flue gases and unburned components.

KIND OF WOOD

HEATING POWER [kWh/kg]

Silver Fir

4,5

Red Fir

4,4

Birch Tree

4,3

Hornbeam

3,9

Beech

4,0

Ash

4,2

Poplar

4,1

Oak

4,2

Locust (Robinia)

4,1

Durmast

4,2

SOME TIPS AND INFORMATION

• 

The best fuel is air dried untreated wood, with a humidity of ≤ 15-18%, beech, hornbeam, oak and acacia are highly 

recommended.

• 

The wood must be stored outdoors in a protected, dry and well-ventilated area.

• 

Excessively humid wood generates lower heat output, faster blackening of the glass and rapid corrosion of the heat 

generator.

• 

The wood must not be too old as it loses its capacity to catch fire (≤ 15 years).

SUITABLE QUALITY AND QUANTITY OF COMBUSTIBLE

The fireplace is designed to burn dry firewood having a water contents less than 15-18%. You can burn combustibles such 

as wood briquettes. 
It should be paid close attention not to put an excessive amount of combustible because it brings the stove to emit an 

excessive amount of heat, so undergoing a warming over the predicted values and then causing really a potential damage 

to the structure as well as increased non-standard gas emissions.

IT IS FORBIDDEN TO BURN:

Burning waste of any kind, in particular plastics, is prohibited by law and because it can damage both the stove and the 

flue gas chimney.

It is also forbidden to burn given materials such as :

• 

Wet wood or bark residues

• 

Chipboard panels or (un)coated panel materials

• 

Paper, cardboard and old clothes 

• 

Plastics and foams

• 

Wood treated with products for conservative treatments

• 

All solid or liquid materials which are not wooden

The efficiency of the fireplace also depends on the chimney draf.

WOOD QUALITY IS VERY IMPORTANT; PLEASE READ THIS SECTION CAREFULLY.

The characteristics of fuel wood for stoves and fireplaces are defined by quality classes A1 and A2 set forth by UNI EN ISO 

17225-5 standard.

WARNING

15

Содержание TERMOJOLLY 80 EVO

Страница 1: ...SM157 EN REV01 2020_01 INSTALLATION USE AND MAINTENANCE MANUAL To be kept by the purchaser Wood operated water system fireplace TERMOJOLLY 80 EVO TERMOJOLLY80EVO...

Страница 2: ...y read and keep this sheet before using the equipment This sheet provides necessary information and suggestions on how to correctly install use clean and maintain the product Knowing and observing the...

Страница 3: ...COLOGICAL REGULATIONS 11 04 1 DISPOSAL OF THE MACHINE 11 CAP 05 DESCRIPTION 12 05 1 PRODUCT PRESENTATION 12 05 2 PRODUCT IDENTIFICATION 13 CAP 06 TECHNICAL DATA 14 06 1 HOMOLOGATION 14 06 2 RECOMMENDE...

Страница 4: ...technical directions for installation contained in this manual should be considered as basic requirements Regulations in some countries may be more restrictive in this instance comply fully with the...

Страница 5: ...EN 60335 1 Household and similar electrical appliances Safety General requirements EN 60335 2 102 Household and similar electrical appliances Safety Particular requirements for gas oil and solid fuel...

Страница 6: ...ight to make modifications to the product and consequently the relative manual without any obligation to update previous editions 01 5 MANUFACTURER S LIABILITY AND WARRANTY CONDITIONS Upon the deliver...

Страница 7: ...ory or mental capabilities or lacking the experience or the needed knowledge can use the device only under surveillance or having been instructed on the device safe use and on the understanding of the...

Страница 8: ...a written Servicing Report to the User informing him that he and the Installation operator shall be jointly liable for any damage to persons animals or things if used Before installing the machine the...

Страница 9: ...produce its systems with the greatest competence regarding safety and consulting all the directives laws and regulations available there are still if minor some residual risks during the phases of TRA...

Страница 10: ...retailer as soon as possible 03 2 LIFTING AND TRANSPORT Personnel in charge of handling the product must have read and thoroughly understood the safety prescriptions in CHAP 02 ACCIDENT PREVENTION SA...

Страница 11: ...ective 2012 19 UE waste electrical and electronic equipment WEEE information for users The crossed out wastebasket symbol on the appliance means that at the end of its useful lifespan the product must...

Страница 12: ...if there is no possibility of an alternative installation The accurate design and engineering of the device has reduced the installation masonry work to a bare minimum The fireplaces are characterize...

Страница 13: ...at the following address http www jolly mec it It is COMPULSORY to indicate the product MODEL the LOT number and SERIAL NUMBER in all communications with the Manufacturer Identification numbers are p...

Страница 14: ...ncy 50 Hz Electrical absorption Nominal std by 0 77 0 77 W Device weight 382 kg Flue draught 10 0 Pa Fume exhaust diameter 250 mm Mass fume flow at nominal output 23 6 g s Average fume T at nominal he...

Страница 15: ...e best fuel is air dried untreated wood with a humidity of 15 18 beech hornbeam oak and acacia are highly recommended The wood must be stored outdoors in a protected dry and well ventilated area Exces...

Страница 16: ...1 Cast iron bottom grate 2 Ash basket 3 Removable key to open the door in vertical sliding mode 4 Electronic control panel pressure transducer probe seat 06 4 DIMENSIONS All measurements are in mm 1 C...

Страница 17: ...internal section which is preferably circular square or rectangular sections must have rounded corners with a radius of no less than 20 mm must have an internal section that is constant free and indep...

Страница 18: ...llow soot to be collected and swept away Changes in cross section are only allowed at the outlet of the heat generator the use of adaptors on the coupling with the chimney flue is prohibited Running o...

Страница 19: ...hydraulic connections and fill the fireplace and the system with water Make sure there are no leaks Phase 2 Connect the chimney to the fireplace smoke exhaust see chap 07 1 Phase 3 Assemble the intern...

Страница 20: ...he combustion chamber with the shaped part a pointing downwards Tilt the panel in order to insert it into the combustion chamber Fig 1 Once inside the combustion chamber it is possible to position it...

Страница 21: ...l must lean on the shaped part b of the fire bed panels 2 Insert the side panel A in the right side and towards the fireplace door Side panel A must be positioned in the combustion chamber with the sh...

Страница 22: ...re bed panels and on the shaped part of the central rear panel 5 Insert the right rear panel C on the central rear panel right side The right rear panel A must be positioned in the combustion chamber...

Страница 23: ...el must lean on the shaped part b of the fire bed panels 6 Insert the side panel A in the left side and towards the side panel already positioned Side panel A must be positioned in the combustion cham...

Страница 24: ...urn it in vertical position to lift it and lean it on its rear panels b and supports c on the side panels c Fig 23 24 e Standard handle disassembly To disassemble the standard handle in order to use t...

Страница 25: ...configuration the fireplace comburent air inlet connection with the outside environment is mandatory Make an opening minimum 600 cm2 in the upper part of the cladding 2 to allow the heat to escape hea...

Страница 26: ...pening in the installation room is mandatory in this configuration Make an opening minimum 600 cm2 in the upper part of the cladding 2 to allow the heat to escape heat recovery that forms inside the c...

Страница 27: ...etween it and the fireplace does not create accumulation of heat The beam must not be inside the fireplace irradiation field see Fig 1 To allow for boiler dilation the cladding must always be detached...

Страница 28: ...INLETS AND OUTLETS In Fig 3 are shown the minimal section sizes suitable for convection air Inlets and Outlets and applicable to all installation types available A Min Convection Air Inlet 600 cm2 B...

Страница 29: ...TROL UNIT ELECTRICAL WIRING DIAGRAM Electrical connections must be carried out by skilled personnel according to the regulations in force 2014 30 EC and 2014 35 EC WARNING The representation of the co...

Страница 30: ...heating see see point c However open vessel installation is possible 1 Cooling coil cooling water inlet with heat discharge valve assembly if not used for open vessel installation it is not to be conn...

Страница 31: ...fireplace Topping up pressure is not automatic It is mandatory to always leave the cold water inlet of the cooling coil water open and the pressure upstream of the heat discharge valve must be at lea...

Страница 32: ...pansion tank supplied with the device has a capacity which is suitable for the system it will be connected to For medium large systems a heat technician should inspect and calculate the needs of the r...

Страница 33: ...p Red Knob to adjust the position of Variable p Venting cycle and the Constant p Pump led colour key LED DESCRIPTION OF FUNCTIONS Off Circulator not connected to the mains Flashing green With the vert...

Страница 34: ...4 Aqueduct water for system loading and cooling coil for closed vessel installation 1 System flow 2 System return 3 Safety discharge for closed vessel installation 4 Aqueduct water for system loading...

Страница 35: ...e to charge again wood as indicated at the end of the chapter 08 2 the wood need to be placed at the center of the fireplace in horizontal sense To maximise fireplace efficiency and avoid the leakage...

Страница 36: ...rloading the fireplace or throwing pieces of wood into the combustion chamber WARNING COMBURENT AIR ADJUSTMENT RECORD MAX position comburent air intake open Fig 5 MIN position comburent air intake clo...

Страница 37: ...ctioning When purchasing firewood it is advisable to vary the sizes but with a length as to be able to light quickly but also long charges and if the quality of the wood is good efficiency and functio...

Страница 38: ...e grasp the removable handle 3 Fig 3 insert it into the specific split 4 and lift it completely Fig 4 To close it again lift it completely c Opening the hinged combustion chamber door with vertical sl...

Страница 39: ...hing correctly To dispose residual ash refer to the municipal national regulations in force Glass Use specific products Be careful not to use overly aggressive product to avoid ruining the frame paint...

Страница 40: ...isconnected from the mains wait until be appliance is cold and comply rigorously with the safety regulations in force WARNING Cleaning the flue Flue cleaning depends on its uptake on the fireplace s u...

Страница 41: ...s Insufficient flue draught there are horizontal sections or 90 bends or the chimney cap is located under the ridge of the roof installation errors Replace the horizontal sections with sections at 45...

Страница 42: ...42 NOTES...

Страница 43: ...ENGLISH NOTES 43...

Страница 44: ...SM157 EN REV01 2020_01 Via S Giuseppe 2 24060 Telgate Bg Italy Tel 39 035 83 59 211 Fax 39 035 83 59 203 www jolly mec it info jolly mec it...

Отзывы: