ENGLISH
Terminal INLETS correspondence
A
common to I1 - I2 Probes of B-C Terminal Blocks
B
Fireplace Water Probe
C
I2* Probe
D
common for I3 Probe
E
I3 Probe, Water Pressure Probe
F
+5V Power for Water Pressure Probe
Terminal OUTLETS correspondence
1
O3 auxiliary Outlet Neutral
2
O1 Fireplace Pump Outlet Neutral (Neutral: - for O2 Outlet for DHW Pump in Scheme 2 – for Buffer Tank in Scheme 5 – for 3-way
diverter Valve in Scheme 6)
3
Network Power Supply Neutral
4
Network Power Supply Phase
5
O3 auxiliary Outlet Phase
6
O2 Outlet Phase
7
O1 Fireplace Pump Outlet Phase
INLETS
GND
A
I1
B
I2
C
GND
D
I3
E
+5V
F
OUTLETS
1
2
3
4
5
6
7
N
N
N
L
O3 O2 O1
230 Vac
07.6
CONTROL UNIT ELECTRICAL WIRING DIAGRAM
Electrical connections must be carried out by skilled personnel according to the regulations in force (2014/30/EC
and 2014/35/EC).
WARNING
The representation of the components is approximate, but they can change in terms of shape.
NOTE
Upstream the electronic board it must be placed a double pole switch thermal breaker to protect the unit and
electromechanical components installed on the fireplace.
WARNING
* The I2 Probe can be of different types according to the Plant Scheme:
•
of PROBE type for the temperature probe - in case of Schemes 5 and 6;
•
of CONTACT type for the thermostat - in case of Schemes 5 and 6.
NOTE
Make sure that the power cable and all other cables do not touch the hot parts of the fireplace.
WARNING
For a full and detailed description of the
content in this section, see the enclosed manual
SM077 EN.