JOHNSON CONTROLS
42
FORM 160.75-N1
ISSUE DATE: 4/30/2014
SECTION 2 - INSTALLATION
TABLE 2 -
APPROXIMATE UNIT WEIGHT INCLUDING MOTOR FOR FLOODED EVAPORATOR UNITS -
LBS (KGS)
SHELLS
COMPRESSOR
SHIPPING
WEIGHT
LBS (KGS)
OPERATING WEIGHT
LBS (KGS)
ESTIMATE
REFRIGERANT
CHARGE LBS (KGS)
A-A
Q3
13,100 (5,942)
15,000 (6,804)
810 (367)
C-B
Q4
18,023 (8,175)
22,323 (10,126)
1,525 (692)
C-C
Q3, Q4
14,920 (6,768)
17,940 (8,138)
1,240 (562)
C-C
Q5
15,330 (6,954)
18,350 (8,324)
1,240 (562)
D-D
Q3, Q4
17,215 (7,809)
21,100 (9,571)
1,680 (762)
D-D
Q5
17,625 (7,995)
21,510 (9,757)
1,680 (762)
E-E
Q3, Q4
17,950 (8,142)
22,160 (10,052)
1,710 (776)
E-E
Q5,Q6,Q7,P7
18,360 (8,328)
22,570 (10,238)
1,710 (776)
E-I
Q7
23,567 (10,690)
29,384 (13,328)
1,805 (819)
F-F
Q5,Q6,Q7,P7
18,720 (8,491)
23,880 (10,832)
2,175 (987)
G-E
P8
20,300 (9,208)
24,200 (10,977)
1,990 (903)
H-F
P8,P9
23,100 (10,478)
28,000 (12,701)
2,610 (1,184)
J-J
P8,P9
24,000 (10,886)
29,100 (13,200)
2,550 (1,157)
L-L
P8,P9
27,400 (12,429)
33,900 (15,377)
3,165 (1,436)
K-K
H9
28,530 (12,941)
36,000 (16,329)
2,925 (1,327)
K-K
K1
31,100 (14,107)
36,200 (16,420)
3,248 (1,473)
K-O
H9
34,483 (15,641)
44,776 (20,310)
3,260 (1,479)
M-M
H9
34,200(15,513)
43,600 (19,777)
3,665 (1,662)
M-M
K1,K2
38,300 (17,373)
47,100 (21,364)
3,665 (1,662)
M-U
K2
45,178 (20,493)
58,017 (26,316)
3,540 (1,606)
N-N
K1,K2
28,530 (18,549)
50,800 (23,043)
4,225 (1,916)
N-N
K3
48,000 (21,773)
54,100 (24,540)
4,225 (1,916)
P-P
K1,K2
41,500 (18,824)
51,900 (23,542)
3,855 (1,749)
Q-Q
K1,K2
45,300 (20,548)
56,800 (25,764)
4,255 (1,930)
Q-Q
K3
46,000 (20,865)
60,200 (27,307)
4,255 (1,930)
R-R
K3
52,800 (23,950)
70,300 (31,888)
4,660 (2,114)
R-R
K4
53,000 (24,041)
70,600 (32,034)
4,785 (2,170)
S-S
K4
59,000 (26,672)
76,300 (34,609)
4,940 (2,241)
S-V
K4
60,100 (27,261)
81,300 (36,877)
5,500 (2,495)
X-T
K4
59,200 (26,853)
80,000 (36,288)
5,125 (2,325)
X-X
K4
66,000 (29,937)
87,000 (39,463)
5,625 (2,551)
W-W
K7
79,500 (36,061)
104,000 (47,174)
6,900 (3,130)
Z-Y
K7
95,300 (43,196)
123,015 (55,799)
6,555 (2,973)
Z-Z
K7
80,500 (36,515)
105,000 (47,628)
6,275 (2,846)
NOTE:
Refrigerant charge quantity and weights will vary based on tube count, configuration, and chiller performance. Use for reference only.
Refer to YORKworks Performance Page or chiller nameplate for actual charge requirement.
Содержание YORK YK Style G OPTIVIEW
Страница 38: ...JOHNSON CONTROLS 38 FORM 160 75 O1 111 NOTES ...
Страница 242: ...FORM 160 54 O1 ISSUE DATE 9 10 2014 JOHNSON CONTROLS 202 SECTION 3 DISPLAY MESSAGES THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 258: ...FORM 160 54 O1 ISSUE DATE 9 10 2014 JOHNSON CONTROLS 218 NOTES ...
Страница 266: ...JOHNSON CONTROLS 6 FORM 160 75 N1 ISSUE DATE 4 30 2014 THIS PAGE INTENTIONALLY LEFT BLANK ...