TFP185

Page 6 of 6

NATIONAL FIRE PROTECTION ASSOCIATION and NFPA are registered trademarks of National Fire Protection Association;

TEFLON is a registered trademark of DuPont; SHERWIN-WILLIAMS is a registered trademark of SWIMC LLC

1400 Pennbrook Parkway, Lansdale, PA 19446 | Tel1-215-362-0700

© 2020 Johnson Controls. All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without notice.

Limited 

Warranty

For warranty terms and conditions, visit 

www.tyco-fire.com.

Ordering 

Procedure

Contact your local distributor for avail-

ability. When placing an order, indicate 

the full product name and Part Number 

(P/N).

Sprinkler 

Assembly

Specify: Model RFII, 5.6 K-factor, Hori-

zontal Sidewall, Flat Plate Concealed 

Sprinkler, Standard Coverage, Quick 

Response, (specify) temperature rating, 

P/N (specify):

160°F (71°C) . . . . . . . . . . . . . . . . . . 50-550-1-165

212°F (100°C) . . . . . . . . . . . . . . . . . 50-550-1-212

Note:

 Sprinkler and Cover Plates are 

separately ordered. See below for 

Cover Plate ordering information.

Separately Ordered 

Cover Plate 

Assembly

Specify: LFII/RFIII Concealed Sprin-

kler Cover Plate Assembly, tempera-

ture rating (specify), (specify) finish, 

P/N (specify):

139°F (59°C)

Ivory (RAL1015)  . . . . . . . . . . . . . . .56-204-0-135

Beige (RAL1001)  . . . . . . . . . . . . . . 56-204-2-135

Pure White (RAL9010)*  . . . . . . . . . 56-204-3-135

Signal White (RAL9003)**  . . . . . . . 56-204-4-135

Grey White (RAL9002) . . . . . . . . . . 56-204-5-135

Brown (RAL8028). . . . . . . . . . . . . .56-204-6-135

Black (RAL9005)  . . . . . . . . . . . . . . 56-204-7-135

Brushed Brass . . . . . . . . . . . . . . . . 56-204-8-135

Brushed Chrome  . . . . . . . . . . . . . . 56-204-9-135

Custom Paint . . . . . . . . . . . . . . . . . 56-204-X-135

165°F (74°C)

Ivory (RAL1015)  . . . . . . . . . . . . . . .56-204-0-165

Bright Chrome  . . . . . . . . . . . . . . . . 56-204-1 165

Beige (RAL1001)  . . . . . . . . . . . . . . 56-204-2-165

Pure White (RAL9010)*  . . . . . . . . . 56-204-3-165

Signal White (RAL9003)**  . . . . . . .56-204-4-165

Grey White (RAL9002) . . . . . . . . . .56-204-5-165

Brown (RAL8028). . . . . . . . . . . . . .56-204-6-165

Black (RAL9005)  . . . . . . . . . . . . . . 56-204-7-165

Brushed Brass . . . . . . . . . . . . . . . .56-204-8-165

Brushed Chrome  . . . . . . . . . . . . . .56-204-9-165

Custom Paint . . . . . . . . . . . . . . . . . 56-204-X-165

* Eastern Hemisphere sales only 
** Previously known as Bright White

Note:

 All Custom Cover Plates are 

painted using SHERWIN-WILLIAMS 

Interior Latex Paint. Contact Johnson 

Controls Customer Service with any 

questions related to custom orders.

Sprinkler Wrench

Specify: W-Type 37 Sprinkler Wrench, 

P/N 56-320-1-015

Pipe Guide Bracket

Pipe Guide Bracket accessory for 

sprinkler installation adjacent to 

framing member such as 2 x 4 within 

wall structure, includes mounting 

screws.

Note:

 The pipe guide bracket is 

required for CPVC installations only.

Specify: Pipe Guide Bracket, P/N 

91-520-115

Содержание tyco RFII

Страница 1: ... form a complete assembly The separable two piece design of the sprinkler provides for 1 4 in 6 4 mm horizontal adjustment of the push on and pull off cover plate With sprinklers installed but before cover plates are attached pressure testing of the fire protection system may be performed prior to completing wall assemblies such as installation of gypsum board over stud framing and surface finish ...

Страница 2: ...e UL Listed for Light and Ordinary Hazard Occupancies at a 4 to 12 in 100mm to 300mm top of deflector to ceiling distance 1 Body 6 Deflector Guide Pin 11 Plug 16 Retainer 2 1 2 in NPT 7 Frame 12 Lever 17 Retainer Friction Grip 3 Wrenching Notch 8 Button 13 Compression Screw 18 Cover Plate Solder Tab 4 Sprinkler Waterway 9 Sealing Assembly 14 Link 19 Cover Plate 5 Deflector 10 Bridge 15 Protective ...

Страница 3: ...rench contains an outer flat surface reference that correlates with the sprinkler deflec tor orientation The word UP on the installation wrench is to face towards the ceiling to ensure proper alignment as shown in Figure 4 NOTICE Do not remove the Protective Cap shown in Figure 1 until the Cover Plate Assembly is installed and or the fire protection sprinkler system is ready to be placed in servic...

Страница 4: ...f it becomes necessary to remove the Cover Plate it can be removed merely by gently pulling the Cover Plate Assembly away from the sprin kler body Note A Cover Plate Assembly not ade quately engaging the sprinkler body that is not securely attached indicates the sprinkler is positioned at a distance from the mounting surface greater than is described in Figure 3 A Cover Plate Assembly fully engage...

Страница 5: ...between the lip of the Cover Plate and the wall as shown in Figure 3 This air gap is necessary for proper oper ation of the sprinkler If the wall is to be repainted after the installation of the sprinkler care must be exercised to ensure that the new paint does not seal off any of the air gap Factory painted cover plates must not be repainted They should be replaced if necessary by factory painted...

Страница 6: ...rin kler Cover Plate Assembly tempera ture rating specify specify finish P N specify 139 F 59 C Ivory RAL1015 56 204 0 135 Beige RAL1001 56 204 2 135 Pure White RAL9010 56 204 3 135 Signal White RAL9003 56 204 4 135 Grey White RAL9002 56 204 5 135 Brown RAL8028 56 204 6 135 Black RAL9005 56 204 7 135 Brushed Brass 56 204 8 135 Brushed Chrome 56 204 9 135 Custom Paint 56 204 X 135 165 F 74 C Ivory ...

Отзывы: