Deleting an Existing Password

To delete an existing password entry, the 

password to be deleted must be used to enter 

the user menu system. Select the 

Delete

 

Password 

option from the 

Password Setup

 

menu, and tap 

OK

 to confirm that you want to 

delete the existing password entry.

Purging All Passwords

In the event a previously entered password 

is forgotten, the user may purge all password 

entries at any time using the 

Purge All

 option.

Display Setup

The

 Display Setup

 menu provides support 

for configuring all of the display settings on 

the CMS-1655. This includes configuring the 

Safety Halo™ settings, selecting the display 

mode based on the number of parameters 

or controllers being monitored, adjusting the 

display brightness, and setting the system 

time and date. Each of these 

Display Setup 

menu options is discussed in more detail in 

the following sections.

Configuring the Safety Halo™

The Safety Halo™ option on the 

Display 

Setup 

menus allows the configuration of 

the settings for the Safety Halo™ status 

indicating bezel, including the 

Nightly Auto-

Dim 

feature. This feature allows the Safety 

Halo™ indicator to automatically reduce its 

brightness to the specified percentage at the 

specified 

Starting Hour

, and return to normal 

brightness at the specified 

Ending Hour

.

To configure the Safety Halo™ settings, select 

the Safety Halo™ option from the 

Display 

Setup

 menu, which invokes the 

Safety Halo™ 

Settings

 configuration screen. The Safety 

Halo™ feature may be enabled or disabled 

by selecting the corresponding radio button. 

If enabled, the normal intensity level may be 

varied between one percent and 100 percent. 

This is the intensity of the Safety Halo™ 

illuminated bezel during normal operating 

hours if 

Nightly Auto-Dim 

is enabled, or 

continuously otherwise. 

To configure the Safety Halo™ feature to 

reduce in brightness intensity during evening 

hours or otherwise, select the 

Nightly Auto-

Dim

 radio button and adjust the 

Dimmed 

Level

 between zero percent and 100 percent. 

To turn off the Safety Halo™ during the 

Nightly Auto-Dim

 period, set the dimmed 

level to zero percent. Tap the 

Next

 button to 

proceed to the next 

Safety Halo™ Settings 

screen where the starting and ending hours of 

the 

Dimmed Period

 may be specified. 

For example, to configure the Safety Halo™ 

feature to reduce in brightness intensity to the 

dimmed level between 7:00 pm and 6:00 am 

every day, set the 

Starting Hour 

to 19 and the 

Ending Hour

 to 6. In this example, the Safety 

Halo™ status indicating bezel will reduce in 

intensity at 7:00 pm every night, and return to 

normal intensity at 6:00 am every morning.

 

Selecting Display Mode

The 

Display Mode

 option on the 

Display 

Setup

 menu allows the units main display 

to be configured based on the number of 

parameters or stations being monitored by the 

CMS-1655. Selecting this option invokes the 

Select Display Mode

 configuration screen as 

shown below in 

Figure 26

Fig. 26 Select Display Mode

Selecting Display Brightness

Selecting the 

Set Brightness

 option on 

the

 Display Setup

 menu invokes the 

Set 

Backlighting Level

 configuration screen as 

shown below in 

Figure 27

. To increase the 

brightness of the display, move the slider to 

the right. Moving the slider to the left reduces 

the brightness down to a minimum level that 

remains visible. Tapping the 

OK

 button stores 

the new brightness setting to non-volatile 

memory, which allows the display to return to 

this brightness level even if a power loss is 

experienced.

SUBHEAD

Due to continuous improvement, JCI reserves the right to change product specifications without notice.

14 

-

PROGRAMMING MANUAL

Содержание CMS-1655

Страница 1: ...ore beginning installation North American Emissions Compliance United States Canada Installation This Class A digital apparatus meets all the requirements of the Canadian Interference Causing Equipmen...

Страница 2: ...655 to Nearest JCI Controller 7 Notes 8 PROGRAMMING MANUAL Introduction 9 Main Setup Menu 9 Unit Setup 10 Configuring Monitor Settings 10 Configuring Audible Alert Settings 11 System Setup 12 Configur...

Страница 3: ...5 or by separate power supply 18 to 32 Vdc Touchscreen User Interface LCDSizeandType 3 2 diagonal transmissive Resolution 240 pixels x 320 pixels portrait mode Viewing Area 50 60 mm x 66 80 mm Color D...

Страница 4: ...parameter is within defined normal operating limits Yellow indicates that the monitored parameter has drifted outside of the normal operating limits and is approaching the alarm region Red indicates t...

Страница 5: ...tainless steel faceplate of the CMS 1655 Run the 4 conductor dual twisted pair electrical connection from the nearest FMS 1650 55 or HMS 1650 55 Refer to the wiring diagram shown on page 7 for details...

Страница 6: ...wn on page 7 for details 6 Terminate the interface cable originating from the host controller at the 4 position and 3 position terminal blocks on the back side of the CMS 1655 display ensuring proper...

Страница 7: ...used to indicate that a door is open at a monitored FMS unit if a door switch has been incorporated with the FMS A red background with the red exclamation point action icon indicates that the monitor...

Страница 8: ...four parameters of up to four independent JCI controllers Once the individual controllers have been specified the parameters at each monitored controller may be selected This is accomplished by tappin...

Страница 9: ...tandard view is selected may be adjusted either by using the hotspots on the main display or by selecting Display Setup Set Time Date The CMS 1655 is also designed to request time and date settings pe...

Страница 10: ...N7 CN3 NETWK NETWK GND V FMS or HMS Backplane Connections Daisy chain together the SUB_NETs on the backplanes of all the FMS 1655 and or HMS 1655 units that will be monitored by the CMS 1655 Connect t...

Страница 11: ...improvement TRIATEK reserves the right to change product specifications without notice Due to continuous improvement JCI reserves the right to change product specifications without notice INSTALLATIO...

Страница 12: ...ed Menu screens time out after 90 seconds of inactivity while configuration screens automatically time out after 60 seconds This prevents unauthorized access to the user menu system should a unit be i...

Страница 13: ...e CMS 1655 Single Station Monitor should be selected if a single controller is being monitored If multiple parameters at a single station need to be monitored then the monitor mode should be specified...

Страница 14: ...lected After selecting the specific stations which should activate the audible alarm when the alarm status occurs pressing the Next button invokes the next configuration screen as shown in Figure 19 w...

Страница 15: ...e configuration settings associated with the CMS 1655 alarm facility may be accessed at the Alarms Setup menu shown in Figure 22 Options on this menu allow individual alarms to be enabled for each of...

Страница 16: ...missioned mode is selected at a monitored HMS 1650 55 These modes are indicated by an action icon represented as a red circle with a line through its center The Safety Halo status indicator if enabled...

Страница 17: ...ormal operating hours if Nightly Auto Dim is enabled or continuously otherwise To configure the Safety Halo feature to reduce in brightness intensity during evening hours or otherwise select the Night...

Страница 18: ...uld be entered as a two digit entry For convenience the time and date may also be entered directly from the main screen Single Station Monitor mode only by tapping the time and date fields respectivel...

Страница 19: ...een made to the network parameters subnetwork address Selecting this option invokes the warning message as shown in Figure 31 informing the user that the CMS 1655 will be reset when the OK button is t...

Страница 20: ...Due to continuous improvement JCI reserves the right to change product specifications without notice User Menu Flow Diagram 17 PROGRAMMING MANUAL...

Страница 21: ...The Next Generation in Critical Airflow Controls CMS 1655 Central Monitoring Station Installation and Programming Manual LB CMS1655 S LB CMS1655 T Code No LIT 12013121 Rev A Issued August 2018 Refer...

Отзывы: