1.
BRIEF DESCRIPTION
1
Air Filter
2
Air circulating fan
3
Fuse
4
Time control
5
Data plate
6
Fan Delay Control
7
Multifunctional control
8
Pilot burner
9
Main burner assembly
10 Gas connection
11 Limit Switch
12 Control panel
13 Piezo unit
14 Summer air circulation switch
15 Spillage monitor device (TTB) (at rear)
16 Draught Diverter
Fig. 1
1.1
JB25P is an open-flued, fan assisted downflow, ducted warm air heater. A Spillage Monitoring Device is fitted which
senses the temperature around the draught diverter, and shuts down the appliance when this temperature rises due to the
presence of flue gases.
1.2
The Air heater output is 7.6kW (27.5MJ/h, 26,000Btu/h). “Summer air circulation” of unheated air is available by manual
selection (see User’s Instructions).
1.3
For Caravan installations, Slot Fit Kit ATL30 is available for this appliance. For Permanent Dwellings, Free-Standing Kit
TC30 and Slot Fit Kits TS30 and TSA30 are available for this appliance.
THIS APPLIANCE CONFORMS TO BS EN 55014
JB25P MK 5 WARM AIR HEATER
INSTALLATION, COMMISSIONING & SERVICING INSTRUCTIONS
G.C. No 42 416 13
Publication No. ZZ 1031/4
August 2004
These instructions are to be left with the User or adjacent to the Gas Appliance
1
Johnson and Starley prides itself on its ability to supply spare parts quickly and efficiently. If you have a problem in
obtaining a spare part, please contact Johnson and Starley Spares Department at the address below.
JOHNSON & STARLEY LTD.
Telephone: (01604) 762881
Rhosili Road,
Brackmills,
Telefax:
(01604) 767408
Northampton NN4 7LZ
1
9 8
5
14
2
16
15
12 3
4
11
6
7
13
10
10.
SHORT LIST OF SPARES
ITEM
G.C.
MAKER’S
DESCRIPTION
QTY
No
No
No
1
381 732
1000-0500130
Fan assembly
1
2
244 925
B300-0182000
Filter tray assembly
1
3
232 962
CL2S
Time control CL2
1
4
244 926
1000-0000070
Time control cover
1
5
384 739
BOS 00105
Limit Switch
1
Honeywell L4069C
6
H26-712
1000-0709640
Multifunctional control
1
Honeywell V8600C 1129
7
232 903
BOS 02061
Sealing ring (for item 6)
2
8
173 096
1000-0704810
Pilot assembly
1
9
E01 088
1000-0703070
Pilot Injector SIT 0.977.149-(15)
1
10
386 820
1000-0703870
Thermocouple SIT 0.290.174
1
11
386 775
BOS 01970
Electrode
1
12
397 819
1000-0705400
Electrode lead
1
13
244 898
BOS 02406
Electrode Nut
1
14
E02 398
B302-0116000
Spillage switch (TTB)
1
15
B265-0800000
Burner and Control Assembly
1
16
E00 411
1000-0705070
Main Burner Arm Furigas 174.500.016
1
17
1000-0708140
Main Injector Bray Cat 23/380
1
18
E02 399
B264-0300005
Heat Exchanger exchange kit
1
19
386 571
1000-0700570
Piezo Unit
1
20
E02 391
B302-0707000
Igniter Bracket
1
21
244 957
1000-2500010
Rope Ring Seal (heat exchanger access cap) 1
22
244 927
1000-0500275
Control Panel
1
23
E02 392
1000-0517730
Wiring Harness
1
24
385 159
BOS 00104
Fan Control Honeywell L4068C-1125
1
25
245 504
1000-0513820
Fuse 3.15A, (T)
1