 I) INTRODUCTION

We thank you for choosing a Flammable Vapour Resistant 
Water Heater. Your satisfaction with this product is very 
important to us. This gas-fired water heater has been 
developed to produce domestic hot water and may also be 
used in combination with space heating applications but 
not space heating only. The Flame Guard

TM 

safety system 

is designed to reduce the risk of flammable vapour related 
fires by trapping the burning vapours within the water heater 
combustion chamber using the special flame arrestor. The 
burning vapours literally “burn themselves out” without 
escaping back into the room.

 User Responsibilities

These instructions have been written for the proper instal-
lation, safe operation and maintenance of this water heater. 
It is your responsibility to ensure that your water heater is 
properly installed and cared for.
FAILURE TO FOLLOW THE INSTRUCTIONS IN THIS 
MANUAL MAY RESULT IN SERIOUS BODILY INJURY 
AND/OR PROPERTY DAMAGE. THOROUGHLY READ ALL 
INSTRUCTIONS BEFORE YOU ATTEMPT TO INSTALL, 
OPERATE OR MAINTAIN THIS HEATER.
Installation and service requires trade knowledge in the 
area of plumbing, electricity, venting, air supply and gas 
supply. If you lack these skills or do not understand these 
instructions, enlist the help of a qualified professional.
The manufacturer of this water heater cannot be held liable 
for those damages caused by improper installation, sizing or 
failure to comply with these instructions.
Protect your warranty: Regularly maintain your water heater 
and venting system as detailed in the “Maintenance” section 
of this manual.

WARNING

Service to the Flame Guard

TM

 safety system 

should only be performed by a qualified ser-
vice technician.

 II) SAFETY

This water heater is design-certified by CSA International as 
a Category I, non-direct vented water heater which takes its 
combustion air either from the installation area or from air 
ducted to the unit from the outside.

In addition to the installation instructions found in this man-
ual, the heater shall be installed according to all local and 
provincial or state codes and with the latest edition of the 
following specifications.

 For Installations in Canada

"Natural Gas and Propane Installation Code" CSA-
B149.1

 and 

"Canadian Electrical Code (CAN/CSA C22.1), 

Part I"

 available from:

Canadian Standards Association,
5060 Spectrum Way,
Mississauga, Ontario, Canada
L4W 5N6

 For Installations in the United States

"National Fuel Gas Code" ANSI Z223.1 (NFPA 54)

 and

"National Electrical Code" (NFPA 70)"

 available from:

American National Standards Institute,
25 West 43rd Street,
New York, NY 10036

Massachusetts code requires this water heater to be 
installed in accordance with Massachusetts Plumbing and 
Fuel Gas Code 248 CMR Section 2.00 and 5.00.

Check your phone listings for the local authorities having 
jurisdiction over your installation.

Important:

 All supply equipment, installation, approvals, 

permits, inspections, etc. are the responsibility of the owner 
of this water heater. Consult your local authorities for regu-
lations specific to your area.

Your safety and the safety of others is very important.

We have provided many important safety messages in this manual and on your appliance. 
Always read and obey all safety messages.

All safety messages will tell you what the potential hazard is, tell you how to reduce the chance 
of injury, and tell you what can happen if the instructions are not followed.

This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word
“DANGER” or “WARNING”.

DANGER

WARNING

You can be killed or seriously injured if you don’t immediately follow 
instructions.

You can be killed or seriously injured if you don’t follow instructions.

 

– 3 – 

Содержание G6058 Series

Страница 1: ...TY Do not store or use gasoline or other flammable vapours and liquids in the vicinity of this or any other appliance Installation and service must be per formed by a qualified installer service agenc...

Страница 2: ...ting Instructions 13 Lighting the Pilot If the Status Light Does Not Blink If the Pilot Does Not Light If the Pilot Lights but the Status Light Does Not Blink Lighting Instructions 14 V OPERATION 15 B...

Страница 3: ...ct vented water heater which takes its combustion air either from the installation area or from air ducted to the unit from the outside In addition to the installation instructions found in this man u...

Страница 4: ...BUSTION AND VENTILATION AIR IS NOT RESTRICTED DANGER Carbon Monoxide Warning Follow all vent system requirements by the local authorities having jurisdiction over your installation Failure to do so ca...

Страница 5: ...ny location selected it is recommended that a suitable drain pan be installed under the water heater This pan must limit the water level to a MAXIMUM depth of 45mm 1 3 4 in and have a diameter that is...

Страница 6: ...xhaust fans ventilation systems clothes dryers fireplaces etc can affect the proper operation of the water heater Special attention must be given to conditions these devices may create Flow reversal o...

Страница 7: ...t leak test liquid Bubbles will indicate leaks Never use a match or open flame to test for gas leaks A fire or explosion could result If leaks exist repair as required and retest DO NOT light the burn...

Страница 8: ...ssary skills required to prop erly install this venting system you should not proceed but enlist the help of a qualified service technician Drafthood Installation SLOPE UP 21mm PER METRE 1 4 in PER ft...

Страница 9: ...mentally handicapped If any one using the hot water fits into one of these groups or if there is a provincial state or local code requiring a certain temperature water at the hot water faucet then you...

Страница 10: ...the data plate of the water heater The Discharge Line Must not be smaller than the pipe size of the relief valve or have any reducing coupling installed in the discharge line Must not be capped blocke...

Страница 11: ...bar on the temperature dial will increase the risk of scald injury Hot water can produce third degree burns in 6 seconds at 60 C 140 F in 30 seconds at 54 C 130 F in 5 minutes at 49 C 120 F 1 Have the...

Страница 12: ...5 seconds 65 149 1 second 2 seconds 68 154 instantaneous 1 seconds U S Government Memorandum C P S C Peter L Armstrong Sept 15 1978 VAC GAS CONTROL TEMPERATURE KNOB STATUS LIGHT IGNITER 120 F MARK 130...

Страница 13: ...ght the Igniter may not be sparking or the unit may not be getting gas or for a new installation there may still be air in the gas line Each time you click the igniter button you should be able to see...

Страница 14: ...e gas control temperature knob and repeat steps 2 through 5 waiting 10 minutes before attempting to relight the pilot If the status light does not start blinking after three lighting attempts turn the...

Страница 15: ...ed in the first 20 minutes from start up due to heavy condensation In this situation if the unit is relit it will fol low its normal heating cycle without further incidents After installation always a...

Страница 16: ...inlet valve and nearby hot faucet until the water is no longer hot 5 Open the water heater drain valve and allow all the water to drain from the tank Flush the tank with water as needed to remove sed...

Страница 17: ...ian Figure 15 T P Relief Valve Test TEMPERATURE AND PRESSURE RELIEF VALVE MANUAL RELIEF VALVE DISCHARGE LINE TO DRAIN Resetting and Replacing the Safety TCO Switch NG models Figure 16 TCO Switch TCO R...

Страница 18: ...control valve thermostat 6 To remove the gas control valve thermostat thread a 100mm 4 in section of gas pipe into the inlet and use it to turn the gas control valve thermostat counter clockwise Do no...

Страница 19: ...tion If such a solution is not available use a mixture of hand dish washing soap and water one part soap to 15 parts water or childrens soap bubble solution Bubbles form ing indicate a leak Correct an...

Страница 20: ...ERMOPILE ASSEMBLY SCREW RETAINER CLIP WHITE WIRE MANIFOLD COMPONENT BLOCK MANIFOLD DOOR BURNER AND OTHER FITTINGS NOT SHOW FOR CLARITY IGNITER WIRE Figure 22 Manifold Door Assembly 6 Read this step ca...

Страница 21: ...ance Do not use piping that has been treated with chromates broiler seal or other chemicals and do not add chemicals to the water heating piping Do not introduce toxic chemicals such as those used for...

Страница 22: ...trol Temperature Knob was not held in for sufficient time 6 Low gas pressure 7 No gas 8 Dirt in gas lines 9 Cold drafts 10 Thermostat ECO switch open 1 Replace igniter pilot assembly 2 See Lighting In...

Страница 23: ...ter heater Check flue way flue baffle and burner 2 Clean locate source and correct 3 Provide fresh air ventilation SMOKING AND CARBON FORMATION SOOTING 1 Insufficient secondary air 2 Low gas pressure...

Страница 24: ...Wait 10 minutes for the Thermopile to cool then attempt to relight Pilot by following the lighting instructions on the water heater s label Until the Thermopile reaches its normal operating temperatu...

Страница 25: ...e minute Remove the outer door Look through the sight glass for a pilot flame If a pilot flame is observed with the gas control valve thermostat knob set to the OFF position the pilot valve is stuck o...

Страница 26: ...D DOOR GASKET 25 BURNER Figure 27 Manifold Door Assembly Vesta 25 14 17 18 19 20 22 23 24 21 15 1 NIPPLE HOT OUTLET 2 NIPPLE COLD INLET 3 DRAFTHOOD 4 TEMPERATURE PRESSURE RELIEF VALVE 6 ANODE 7 DIP TU...

Страница 27: ...e water heater s Model Number SKU Serial Number date of purchase and date of installation c THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF THIS EXPRESS WARRANTY IS WHER...

Страница 28: ...cy beyond the control of the Manufacturer or s The water heater is installed in a closed system without adequate provision for thermal expansion 3 Except when speci cally prohibited by the applicable...

Отзывы: