background image

 Lighting Instructions

1. Tournez le bouton de réglage du gaz/température dans le sens antihoraire        

jusqu'à la position "OFF". Le témoin lumineux cesse de clignoter et reste allumé un 
court moment après l'arrêt du chauffe-eau (Figure A).

COUPER L’ALIMENTATION EN GAZ DE L’APPAREIL

1. Turn the gas control/temperature knob counterclockwise        to 

the "OFF" setting. The status light will stop blinking and stay on 
for a short time after the water heater is turned off. See Figure ‘A’.

TO TURN OFF GAS TO APPLIANCE

320217-000

1. ARRÊTEZ! Il est essentiel de lire attentivement tous les messages d’avertissement 

avant d’allumer la veilleuse.

2. Tournez le bouton de réglage du gaz/température dans le sens antihoraire        

jusqu'à la position "OFF".

3. Afin de laisser se dissiper tout gaz ayant pu s'accumuler, attendez dix (10) minutes. 

Si vous détectez une odeur de gaz, ARRÊTEZ! Suivez la directive de sécurité "B" au 
haut de cette étiquette. Si vous ne détectez pas d’odeur de gaz, procédez à la 
prochaine étape.

4. Tournez le bouton de réglage du gaz/température dans le sens horaire        jusqu'à la 

position "PILOT" (Figure B).

5. Appuyez complètement sur le bouton de réglage du gaz/température et maintenez-le 

enfoncé. Le bouton peut s'enfoncer d'environ 6 mm (1/4 po), lorsqu'il est bien 
positionné à "PILOT". Tout en maintenant le bouton de réglage du gaz/température 
enfoncé, appuyez de façon répétitive (une fois par seconde) sur le bouton de 
l'allumeur (jusqu'à 90 secondes), ou jusqu'à ce que le témoin lumineux s'allume.

6. Lorsque le témoin lumineux se met à clignoter, relâchez le bouton de réglage du 

gaz/température. Réglez le bouton à la position désirée (Figure C).

    Si le témoin lumineux ne se met pas à clignoter en moins de 90 secondes, reprenez 

les étapes 2 à 5 jusqu'à TROIS (3) reprises, en prenant une pause de 10 minutes 
entre chaque essai d'allumage.

    Le processeur sophistiqué de cette commande du gaz force une période d'attente de 

10 minutes entre chaque essai d'allumage.

    Si le témoin lumineux passe au rouge de façon continue, relâchez le bouton de 

réglage du gaz/température et reprenez les étapes 2 à 5, en prenant une pause de 10 
minutes entre chaque essai d'allumage. Si le témoin lumineux ne se met pas à 
clignoter en trois essais d'allumage, ramenez le bouton de réglage du 
gaz/température à la position "OFF" et faites appel à un technicien d'entretien 
qualifié ou à votre fournisseur du gaz.

DANGER: Plus l’eau est chaude, plus le risque d’ébouillantage est élevé. 
Consultez les directives du manuel à ce sujet avant de régler la température.

    

Reportez-vous aux Directives d'allumage du manuel d'installation pour des 

instructions de dépannage plus détaillées.

DANGER: 

DIRECTIVES D’UTILISATION

1. STOP! It is imperative that you read all safety warnings before 

lighting the pilot.

2. Turn the gas control/temperature knob counterclockwise        to 

the "OFF" setting.

3. Wait ten (10) minutes to clear out any gas. If you then smell gas, 

STOP! Follow “ B” in the safety information above on this label. If 
you do not smell gas, go to the next step.

4. Turn the gas control/temperature knob clockwise        to “PILOT”. 

See Figure ‘B’.

5. Press the gas control/temperature knob all the way in and hold it 

in. The knob should travel in about 6mm (1/4 inch) if it is set to 
"PILOT" correctly. While holding the gas control/temperature 
knob in, click the igniter button continuously (about once a 
second) for up to 90 seconds or until Status Light begins to blink.

6. When the status light starts blinking, release the gas 

control/temperature knob. Set the gas control/temperature knob 
to the desired setting. See Figure ‘C’.

    If the status light does not start blinking within 90 seconds, repeat 

steps 2 through 5 up to THREE (3) times, waiting 10 minutes 
between lighting attempts.

    The circuitry in this advanced gas valve requires that you wait 10 

minutes between lighting attempts.

    If the status light turns solid red, release the gas 

control/temperature knob and repeat steps 2 through 5 (waiting 
10 minutes before attempting to relight the pilot). If the status 
light does not start blinking after three lighting attempts, turn the 
gas control/temperature knob to "OFF" and call a qualified 
service technician or your gas supplier.

DANGER: Hotter water increases the risk of scald injury. 
Consult the instruction manual before changing 
temperature.

    Refer to the Lighting Instructions in the Installation Manual for 

more detailed troubleshooting information.

DANGER: 

OPERATING INSTRUCTIONS

FIGURE  'D'

MAIN BURNER / BRÛLEUR

THERMOPILE

PILOT / VEILLEUSE

FIGURE  'A'

"OFF" POSITION

POSITION "OFF"

FIGURE  'B'

"PILOT" POSITION

POSITION "PILOT"

FIGURE  'C'

"ON" POSITION

POSITION "ON"

Repère

120°F

Mark

Repère

120°F

Mark

CONTROL KNOB / BOUTON DE RÉGLAGE DU GAZ

Repère

120°F

Mark

GAS CONTROL / COMMANDE DU GAZ

Gas Control & Temperature Knob / 

Bouton réglage du gaz & temp.

Status Light /

Témoin 

lumineux

Igniter / Allumeur

A. L’allumage de la veilleuse de cet appareil au gaz est assuré par un système 

d’allumage piézoélectrique à étincelles. Ne tentez pas d’ouvrir la porte d’accès 
interne et d’allumer la veilleuse manuellement.

B. AVANT L’ALLUMAGE, humez l’air tout autour de l’appareil afin d’y déceler une 

éventuelle odeur de gaz. Humez aussi l'air près du sol, car certains gaz sont plus 
lourds que l’air et s’y accumulent.

SI VOUS DÉTECTEZ UNE ODEUR DE GAZ
   • Ne mettez aucun appareil en marche.
   • Ne touchez à aucun interrupteur; ne vous servez pas des téléphones se trouvant 

dans le bâtiment.

   • Appelez immédiatement votre fournisseur de service de gaz à partir du téléphone 

d’un voisin et suivez ses directives.

   • Si vous ne pouvez communiquer avec votre fournisseur de service de gaz, appelez 

le service des incendies.

C. Le bouton de réglage du gaz ne doit être enfoncé ou tourné qu’à la main; n’utilisez 

jamais d’outil. Si le bouton reste coincé, ne tentez pas une réparation; appelez 
plutôt un technicien d'entretien qualifié. Si vous forcez ou tentez de réparer le 
bouton, il a risque d’explosion ou d’incendie.

D. N’utilisez pas cet appareil même s’il n’a été que partiellement submergé par de 

l’eau. Communiquez immédiatement avec un installateur qualifié ou un centre de 
service afin de faire remplacer tout chauffe-eau ayant été submergé lors d’une 
inondation. Ne tentez jamais de réparer l’appareil! Il doit être remplacé!

AVANT L’ALLUMAGE: LE RÉSEAU D’ALIMENTATION 

EN EAU DOIT ÊTRE ENTIÈREMENT REMPLI D’EAU 

ET L’AIR ENTIÈREMENT PURGÉ

AVERTISSEMENT:

 Tout manquement aux présentes 

directives peut causer un incendie ou une explosion entraînant  

des dommages matériels, des blessures ou la mort.

POUR VOTRE SÉCURITÉ, LISEZ 

ATTENTIVEMENT AVANT L’ALLUMAGE

A. This appliance has a pilot which is lit by a piezoelectric spark 

gas ignition system. Do not open the inner door of the appliance 
and try to light the pilot by hand.

B. BEFORE LIGHTING smell all around the appliance area for gas. 

Be sure to smell next to the floor because some gas is heavier 
than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS
   • Do not try to light any appliance.
   • Do not touch any electric switch; do not use any phone in your 

building.

   • Immediately call your gas supplier from a neighbor's phone. 

Follow the gas supplier's instructions.

   • If you cannot reach your gas supplier, call the fire department.
C. Use only your hand to push in or turn the gas control knob. 

Never use tools. If the knob will not push in or turn by hand, 
don't try to repair it, call a qualified service technician. Force or 
attempted repair may result in a fire or explosion.

D. Do not use this appliance if any part has been under water. 

Immediately contact a qualified installer or service agency to 
replace a flooded water heater. Do not attempt to repair the unit! 
It must be replaced!

BEFORE LIGHTING: ENTIRE SYSTEM 

MUST BE FILLED WITH WATER AND AIR 

PURGED FROM ALL LINES

WARNING: 

If you do not follow these instructions 

exactly, a fire or explosion may result causing 

property damage, personal injury or loss of life.

FOR YOUR SAFETY READ

BEFORE LIGHTING

 

– 14 – 

Содержание G6058 Series

Страница 1: ...TY Do not store or use gasoline or other flammable vapours and liquids in the vicinity of this or any other appliance Installation and service must be per formed by a qualified installer service agenc...

Страница 2: ...ting Instructions 13 Lighting the Pilot If the Status Light Does Not Blink If the Pilot Does Not Light If the Pilot Lights but the Status Light Does Not Blink Lighting Instructions 14 V OPERATION 15 B...

Страница 3: ...ct vented water heater which takes its combustion air either from the installation area or from air ducted to the unit from the outside In addition to the installation instructions found in this man u...

Страница 4: ...BUSTION AND VENTILATION AIR IS NOT RESTRICTED DANGER Carbon Monoxide Warning Follow all vent system requirements by the local authorities having jurisdiction over your installation Failure to do so ca...

Страница 5: ...ny location selected it is recommended that a suitable drain pan be installed under the water heater This pan must limit the water level to a MAXIMUM depth of 45mm 1 3 4 in and have a diameter that is...

Страница 6: ...xhaust fans ventilation systems clothes dryers fireplaces etc can affect the proper operation of the water heater Special attention must be given to conditions these devices may create Flow reversal o...

Страница 7: ...t leak test liquid Bubbles will indicate leaks Never use a match or open flame to test for gas leaks A fire or explosion could result If leaks exist repair as required and retest DO NOT light the burn...

Страница 8: ...ssary skills required to prop erly install this venting system you should not proceed but enlist the help of a qualified service technician Drafthood Installation SLOPE UP 21mm PER METRE 1 4 in PER ft...

Страница 9: ...mentally handicapped If any one using the hot water fits into one of these groups or if there is a provincial state or local code requiring a certain temperature water at the hot water faucet then you...

Страница 10: ...the data plate of the water heater The Discharge Line Must not be smaller than the pipe size of the relief valve or have any reducing coupling installed in the discharge line Must not be capped blocke...

Страница 11: ...bar on the temperature dial will increase the risk of scald injury Hot water can produce third degree burns in 6 seconds at 60 C 140 F in 30 seconds at 54 C 130 F in 5 minutes at 49 C 120 F 1 Have the...

Страница 12: ...5 seconds 65 149 1 second 2 seconds 68 154 instantaneous 1 seconds U S Government Memorandum C P S C Peter L Armstrong Sept 15 1978 VAC GAS CONTROL TEMPERATURE KNOB STATUS LIGHT IGNITER 120 F MARK 130...

Страница 13: ...ght the Igniter may not be sparking or the unit may not be getting gas or for a new installation there may still be air in the gas line Each time you click the igniter button you should be able to see...

Страница 14: ...e gas control temperature knob and repeat steps 2 through 5 waiting 10 minutes before attempting to relight the pilot If the status light does not start blinking after three lighting attempts turn the...

Страница 15: ...ed in the first 20 minutes from start up due to heavy condensation In this situation if the unit is relit it will fol low its normal heating cycle without further incidents After installation always a...

Страница 16: ...inlet valve and nearby hot faucet until the water is no longer hot 5 Open the water heater drain valve and allow all the water to drain from the tank Flush the tank with water as needed to remove sed...

Страница 17: ...ian Figure 15 T P Relief Valve Test TEMPERATURE AND PRESSURE RELIEF VALVE MANUAL RELIEF VALVE DISCHARGE LINE TO DRAIN Resetting and Replacing the Safety TCO Switch NG models Figure 16 TCO Switch TCO R...

Страница 18: ...control valve thermostat 6 To remove the gas control valve thermostat thread a 100mm 4 in section of gas pipe into the inlet and use it to turn the gas control valve thermostat counter clockwise Do no...

Страница 19: ...tion If such a solution is not available use a mixture of hand dish washing soap and water one part soap to 15 parts water or childrens soap bubble solution Bubbles form ing indicate a leak Correct an...

Страница 20: ...ERMOPILE ASSEMBLY SCREW RETAINER CLIP WHITE WIRE MANIFOLD COMPONENT BLOCK MANIFOLD DOOR BURNER AND OTHER FITTINGS NOT SHOW FOR CLARITY IGNITER WIRE Figure 22 Manifold Door Assembly 6 Read this step ca...

Страница 21: ...ance Do not use piping that has been treated with chromates broiler seal or other chemicals and do not add chemicals to the water heating piping Do not introduce toxic chemicals such as those used for...

Страница 22: ...trol Temperature Knob was not held in for sufficient time 6 Low gas pressure 7 No gas 8 Dirt in gas lines 9 Cold drafts 10 Thermostat ECO switch open 1 Replace igniter pilot assembly 2 See Lighting In...

Страница 23: ...ter heater Check flue way flue baffle and burner 2 Clean locate source and correct 3 Provide fresh air ventilation SMOKING AND CARBON FORMATION SOOTING 1 Insufficient secondary air 2 Low gas pressure...

Страница 24: ...Wait 10 minutes for the Thermopile to cool then attempt to relight Pilot by following the lighting instructions on the water heater s label Until the Thermopile reaches its normal operating temperatu...

Страница 25: ...e minute Remove the outer door Look through the sight glass for a pilot flame If a pilot flame is observed with the gas control valve thermostat knob set to the OFF position the pilot valve is stuck o...

Страница 26: ...D DOOR GASKET 25 BURNER Figure 27 Manifold Door Assembly Vesta 25 14 17 18 19 20 22 23 24 21 15 1 NIPPLE HOT OUTLET 2 NIPPLE COLD INLET 3 DRAFTHOOD 4 TEMPERATURE PRESSURE RELIEF VALVE 6 ANODE 7 DIP TU...

Страница 27: ...e water heater s Model Number SKU Serial Number date of purchase and date of installation c THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF THIS EXPRESS WARRANTY IS WHER...

Страница 28: ...cy beyond the control of the Manufacturer or s The water heater is installed in a closed system without adequate provision for thermal expansion 3 Except when speci cally prohibited by the applicable...

Отзывы: