b.  The water heater has not been installed in accordance with the applicable local plumbing and/or building code(s) 

and/or regulations or, in their absence, with the latest edition of the Natural Gas and Propane Installation Code, 

and/or the Canadian Electrical Code; or

 

c.  The water heater is not installed, operated, and maintained in accordance with the Manufacturer’s instructions, 

including if the water heater has any additional aftermarket equipment introduced into the sealed system not ap-

proved by the Manufacturer; or

 

d.  The water heater or any of its component parts are damaged or fails from operation with an empty or partially empty 

tank (such as, but not limited to elements burned out in a dry tank); or

 

e.  The water heater or any part has been under water; or

 

f.  The water heater is exposed to highly corrosive atmospheric conditions. No warranty extends, for example, and 

without limitation of the foregoing, to Units exposed to: salts, chemicals, exhausts, pollutants, or contaminants; or

 

g.  The water heater is not continuously supplied with potable water; or

 

h.  The water heater replacement is requested for reasons of noise, taste, odour, discolouration, and/or rust; or

 

i.  The water heater is operated at temperatures exceeding the maximum setting of the thermostat and/or high limit 

control provided by the Manufacturer, or at water pressures exceeding the pressure reading stated on the Unit; or

 

j.  The water heater is operated without an operating anode; or

 

k.  The water heater is supplied or operated with deionized water; or

 

l.  The water heater is removed from its original installation location; or

 

m. The water heater is installed outdoors (this water heater is intended only for indoor installation); or

 

n.  The water heater is converted, or is attempted to be converted, from one voltage or wattage to another, if an electric 

water heater, or from one gas type to another, if a gas water heater; or

 

o.  The water heater has not been 

¿

 red at the factory rated input and fuel for which it was factory built; or

 

p.  The water heater or any of its component parts fail due to sediment build-up; or

 

q.  The water heater does not have installed a properly operating temperature and pressure relief valve, certi

¿

 ed to 

ANSI Z21.22/CSA “Requirements for Relief Valves for Hot Water Supply Systems”; or 

 

r.  The water heater or any of its component parts fail because of 

¿

 re, 

À

 oods, lightning, or any other act of God, or any 

other contingency beyond the control of the Manufacturer; or

 

s.  The water heater is installed in a closed system without adequate provision for thermal expansion.

  3. Except when speci

¿

 cally prohibited by the applicable law, the Owner, and not the Manufacturer, shall be liable for 

and shall pay for all charges for labour or other expenses incurred in the removal, repair, or replacement of the water 

heater or any component part(s) claimed to be defective or any expense incurred to remedy any defect in the product. 

Such charges may include, but are not necessarily limited to:

 

a.  All freight, shipping, handling, and delivery costs of forwarding a new water heater or replacement part(s) to the 

Owner.

 

b.  All costs necessary or incidental in removing the defective water heater or component part(s) and installing a new 

water heater or component part(s).

 

c.  Any material required to complete and/or permits required for the installation of a new water heater or replacement 

part(s), and

 

d.  All costs necessary or incidental in returning the defective water heater or component part(s) to a location desig-

nated by the Manufacturer.

 

4.  The terms of this Limited Warranty cannot be modi

¿

 ed by any person, whether or not he/she claims to represent or 

act on behalf of the Manufacturer.

E.  HOW THE ORIGINAL OWNER CAN MAKE A WARRANTY CLAIM.

  1. The Owner should submit the warranty claim direct to the Manufacturer’s Service Department, at the address or phone 

number listed below, and the Manufacturer will arrange for the handling of the claim.

  2. Whenever any inquiry or request is made, be sure to include the water heater’s Catalogue Number, Model Number, 

Serial Number, date of purchase, date of installation, and location of installation.

This Warranty and the Manufacturer’s obligations shall be construed and determined in accordance with the laws of both the 

Province of Ontario, and of Canada in force therein. This Warranty does not affect speci

¿

 c legal rights of a consumer under 

applicable law, except to the extent that such rights may be waived or replaced, and the provisions hereof are deemed to be 

amended to the extent necessary. The unenforceability of any provision, in whole or in part, of this Certi

¿

 cate shall not affect 

the remaining provisions. Any and all repair and/or replacement of part(s) or Unit are the sole and exclusive remedy avail-

able against the Manufacturer.

John Wood Water Heaters

599 Hill Street West

Fergus, ON Canada N1M 2X1

Should you have any questions, please

Visit us online at 

www.johnwoodwaterheaters.com

, or

E-mail us at [email protected], or

Call our Technical Support line at 1 888 GSW TECH (479 8324)

 

– 28 – 

Содержание G6058 Series

Страница 1: ...TY Do not store or use gasoline or other flammable vapours and liquids in the vicinity of this or any other appliance Installation and service must be per formed by a qualified installer service agenc...

Страница 2: ...ting Instructions 13 Lighting the Pilot If the Status Light Does Not Blink If the Pilot Does Not Light If the Pilot Lights but the Status Light Does Not Blink Lighting Instructions 14 V OPERATION 15 B...

Страница 3: ...ct vented water heater which takes its combustion air either from the installation area or from air ducted to the unit from the outside In addition to the installation instructions found in this man u...

Страница 4: ...BUSTION AND VENTILATION AIR IS NOT RESTRICTED DANGER Carbon Monoxide Warning Follow all vent system requirements by the local authorities having jurisdiction over your installation Failure to do so ca...

Страница 5: ...ny location selected it is recommended that a suitable drain pan be installed under the water heater This pan must limit the water level to a MAXIMUM depth of 45mm 1 3 4 in and have a diameter that is...

Страница 6: ...xhaust fans ventilation systems clothes dryers fireplaces etc can affect the proper operation of the water heater Special attention must be given to conditions these devices may create Flow reversal o...

Страница 7: ...t leak test liquid Bubbles will indicate leaks Never use a match or open flame to test for gas leaks A fire or explosion could result If leaks exist repair as required and retest DO NOT light the burn...

Страница 8: ...ssary skills required to prop erly install this venting system you should not proceed but enlist the help of a qualified service technician Drafthood Installation SLOPE UP 21mm PER METRE 1 4 in PER ft...

Страница 9: ...mentally handicapped If any one using the hot water fits into one of these groups or if there is a provincial state or local code requiring a certain temperature water at the hot water faucet then you...

Страница 10: ...the data plate of the water heater The Discharge Line Must not be smaller than the pipe size of the relief valve or have any reducing coupling installed in the discharge line Must not be capped blocke...

Страница 11: ...bar on the temperature dial will increase the risk of scald injury Hot water can produce third degree burns in 6 seconds at 60 C 140 F in 30 seconds at 54 C 130 F in 5 minutes at 49 C 120 F 1 Have the...

Страница 12: ...5 seconds 65 149 1 second 2 seconds 68 154 instantaneous 1 seconds U S Government Memorandum C P S C Peter L Armstrong Sept 15 1978 VAC GAS CONTROL TEMPERATURE KNOB STATUS LIGHT IGNITER 120 F MARK 130...

Страница 13: ...ght the Igniter may not be sparking or the unit may not be getting gas or for a new installation there may still be air in the gas line Each time you click the igniter button you should be able to see...

Страница 14: ...e gas control temperature knob and repeat steps 2 through 5 waiting 10 minutes before attempting to relight the pilot If the status light does not start blinking after three lighting attempts turn the...

Страница 15: ...ed in the first 20 minutes from start up due to heavy condensation In this situation if the unit is relit it will fol low its normal heating cycle without further incidents After installation always a...

Страница 16: ...inlet valve and nearby hot faucet until the water is no longer hot 5 Open the water heater drain valve and allow all the water to drain from the tank Flush the tank with water as needed to remove sed...

Страница 17: ...ian Figure 15 T P Relief Valve Test TEMPERATURE AND PRESSURE RELIEF VALVE MANUAL RELIEF VALVE DISCHARGE LINE TO DRAIN Resetting and Replacing the Safety TCO Switch NG models Figure 16 TCO Switch TCO R...

Страница 18: ...control valve thermostat 6 To remove the gas control valve thermostat thread a 100mm 4 in section of gas pipe into the inlet and use it to turn the gas control valve thermostat counter clockwise Do no...

Страница 19: ...tion If such a solution is not available use a mixture of hand dish washing soap and water one part soap to 15 parts water or childrens soap bubble solution Bubbles form ing indicate a leak Correct an...

Страница 20: ...ERMOPILE ASSEMBLY SCREW RETAINER CLIP WHITE WIRE MANIFOLD COMPONENT BLOCK MANIFOLD DOOR BURNER AND OTHER FITTINGS NOT SHOW FOR CLARITY IGNITER WIRE Figure 22 Manifold Door Assembly 6 Read this step ca...

Страница 21: ...ance Do not use piping that has been treated with chromates broiler seal or other chemicals and do not add chemicals to the water heating piping Do not introduce toxic chemicals such as those used for...

Страница 22: ...trol Temperature Knob was not held in for sufficient time 6 Low gas pressure 7 No gas 8 Dirt in gas lines 9 Cold drafts 10 Thermostat ECO switch open 1 Replace igniter pilot assembly 2 See Lighting In...

Страница 23: ...ter heater Check flue way flue baffle and burner 2 Clean locate source and correct 3 Provide fresh air ventilation SMOKING AND CARBON FORMATION SOOTING 1 Insufficient secondary air 2 Low gas pressure...

Страница 24: ...Wait 10 minutes for the Thermopile to cool then attempt to relight Pilot by following the lighting instructions on the water heater s label Until the Thermopile reaches its normal operating temperatu...

Страница 25: ...e minute Remove the outer door Look through the sight glass for a pilot flame If a pilot flame is observed with the gas control valve thermostat knob set to the OFF position the pilot valve is stuck o...

Страница 26: ...D DOOR GASKET 25 BURNER Figure 27 Manifold Door Assembly Vesta 25 14 17 18 19 20 22 23 24 21 15 1 NIPPLE HOT OUTLET 2 NIPPLE COLD INLET 3 DRAFTHOOD 4 TEMPERATURE PRESSURE RELIEF VALVE 6 ANODE 7 DIP TU...

Страница 27: ...e water heater s Model Number SKU Serial Number date of purchase and date of installation c THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF THIS EXPRESS WARRANTY IS WHER...

Страница 28: ...cy beyond the control of the Manufacturer or s The water heater is installed in a closed system without adequate provision for thermal expansion 3 Except when speci cally prohibited by the applicable...

Отзывы: