background image

 Joerns

®

 EasyCare

®

 Bed Platform

Model ECS

17

Trapeze 

(Figure 36)

1.  We recommend using the Joerns

®

 Trapeze with 

the Joerns Trapeze Adapter.

2.  Install the Trapeze assembly according to 

manufacturer’s directions included with the 

Trapeze.

Trapeze Adapter 

(Figure 37)

1.  The Trapeze Adapter is designed to allow 

attachment of the Trapeze system to the 

EasyCare

®

 Bed. Prior to use, please read 

important warnings related to this option and 

follow all instructions below.

2.  Install the Trapeze Adapter according to the 

supplied instructions. If needed, call Technical 

Support at 800-826-0270 for instructions.

3.  Install the trapeze assembly onto the Trapeze 

Adapter according to the trapeze manufacturer’s 

instructions.

4.  Operate the bed from its highest through lowest 

positions to ensure proper clearance and 

operation. Some trapeze systems may not be 

suitable for use with the EasyCare Bed, due to 

its low operating height. 

5.  Adjustment and use of a Trapeze should be in 

accordance with instructions from a healthcare 

professional (doctor or therapist).

6.  Do not exceed the maximum load condition 

listed on installation instructions.

4-Inch Extender

 (Figure 38)

1.  The 4-Inch Extender is designed to extend the 

mattress support platform about four inches 

to allow the use of an 84-inch mattress on an 

80-inch mattress support platform or an 80-inch 

mattress on a 76-inch mattress support platform. 

Prior to use, please read important warnings 

related to the Extender and follow instructions 

below. 

2.  Install the 4-Inch Extender according to supplied 

instructions. If needed, call Technical Support at 

800-826-0270 for instructions.

3.  Make sure the increase in overall length 

does not produce a safety hazard or impair 

accessibility in the room. Place the new mattress 

against the Mattress Stop and be sure the 

mattress covers the entire mattress support 

platform length.

Figure 38

Figure 37

Figure 36

Содержание ECS EasyCare 3

Страница 1: ...Joerns Healthcare EasyCare 5 EasyCare 7 EasyCare 9 User Service Manual Joerns EasyCare Bed Platform Model ECS leading bed evolution To avoid injury read user s manual before using EasyCare 3...

Страница 2: ...ble Shock Hazard Injury may result from improper routing of the power cord Always follow the proper factory installed routing configuration Failure to do so could result in injury or death Warning Pos...

Страница 3: ...less than 1 5 inches under user s weight Warning Possible Injury or Death Floor locks increase bed stability and resident safety Make sure the bed is in a locked position with respect to the floor by...

Страница 4: ...althcare can offer you the expertise assistance and products to bring your facility into compliance Joerns Compliance Solutions Matching the right bed components in order to meet regulatory guidelines...

Страница 5: ...Sensor EasyCare 9 Power 120 VAC Frequency 60 Hz Current Rating 4 0 Amps 120V Classification Class I Type B or Class II Type B Mode of Operation 10 Maximum Duty Cycle 2 minutes on 18 minutes off Circui...

Страница 6: ...face down 3 The foot panel brackets are the shorter of two sizes Figure 1 4 Install the foot panel brackets with the four screws provided The bracket offset should face up Figure 2 Do not tighten unti...

Страница 7: ...e mattress side stop into the hole on one side 6 Compress the mattress side stop and insert into the opposite hole on the head end of the mattress support platform IV Sockets Joerns EasyCare Bed Platf...

Страница 8: ...15 Operation Pendant Operation EasyCare 3 5 and 7 Your Joerns EasyCare 3 EasyCare 5 or EasyCare 7 bed comes standard with the snap in pendant The pendant has raised high contrast buttons and graphics...

Страница 9: ...e 19 Figure 20 Figure 21 Figure 22 EasyCare 9 1 Your EasyCare 9 bed comes standard with a pendant Figure 18 The pendant plugs into a port under either side of the seat pan 2 Unscrew the cap Figure 19...

Страница 10: ...ock graphic on the panel and push the function to unlock Amber LED is no longer illuminated signaling that the function is now operable Pendant Lockout and Bed Operation 1 Push button to lock out Back...

Страница 11: ...cked position by a red symbol Figure 28 3 To unlock the UltraLock place the ball of your foot on any pedal and push down Figure 29 The label indicates the mobile position by a green symbol Figure 28 W...

Страница 12: ...bed function fails to operate Ensure that the bed is not overloaded or constrained from movement Actuator and Control Box Information Cord and Socket Identification Figures 31 and 32 1 Back Actuator...

Страница 13: ...Control Box contain no serviceable parts Overload protection is achieved via current sensing technology which will automatically reset If any bed function fails to operate check to see if the bed is o...

Страница 14: ...ties that holds the power cable to the frame Tape the remaining cables in their original position It is very important to keep the actuator cables routed along the frame in their original factory ins...

Страница 15: ...es or less Do not surpass 10 duty cycle 2 min on 18 min off 2 If these steps fail to resolve the problem call Technical Support at 800 826 0270 1 Switch the pendant with a new pendant or one from a be...

Страница 16: ...ght in these locations Failure to do so could increase risk of suffocation or result in injury or death Warning Possible Injury The extender is designed for use with a foot panel Sitting on or sliding...

Страница 17: ...itable for use with the EasyCare Bed due to its low operating height 5 Adjustment and use of a Trapeze should be in accordance with instructions from a healthcare professional doctor or therapist 6 Do...

Страница 18: ...rest on the floor particularly when the bed is in its lowest position Otherwise a safety condition may occur or the function of attached items may be impacted Bed Transport Bar Figure 40 1 The Bed Tra...

Страница 19: ...he Battery will be fully charged Note We recommend that users charge up the Battery immediately upon receipt 4 The Battery has a useful life of about 3 5 years depending upon usage It is recommended t...

Страница 20: ...s Joerns beds contain various parts that wear from normal use These parts such as DC batteries are not covered under the three year warranty but are covered for 90 days after date of delivery Joerns H...

Отзывы: