them is large enough for trunk and hips to pass 

through easily. Make sure raising or lowering bed, 

or contouring sleep surface does not create any 

hazardous gaps. Failure to do so could result 

in injury or death. 

Important Note:

 Powered air 

mattress surfaces may pose a risk of entrapment. 

Prior to use, ensure the therapeutic benefits 

outweigh the risk of entrapment. 

Warning: Possible Injury Or Death.

 Do not use 

an assist device if any openings within assist device 

body allow resident/patient to get his/her head or 

neck lodged within these openings. Use of assist 

devices with large openings may result in injury or 

death.

Warning: Possible Injury Or Death.

 Do not use 

any Joerns

®

 assist device until you verify it is locked 

in place. Failure to lock assist devices may result in 

injury or death.

Warning: Possible Injury Or Death. 

Do not use 

any replacement parts not manufactured, marketed 

or provided by Joerns Healthcare on any Joerns 

bed. Use of unapproved replacement parts may 

result in injury or death.

Warning: Possible Injury Or Death. 

If using 

accessories not manufactured, marketed or provided 

by Joerns Healthcare for Joerns beds, consult with 

the manufacturer for compatibility and limitations 

prior to use. Failure to do so may result in injury  

or death.

Warning: Possible Shock Hazard. 

If the bed power 

cord has a hospital-grade, 3-prong grounding plug, 

grounding reliability can only be achieved when 

equipment is connected to an equivalent receptacle 

marked hospital-grade.

Warning: Possible Injury.

 Sitting on or sliding over 

the Mattress Side Stop can cause skin injury if the 

bed mattress compresses to less than 1.5 inches 

under user’s weight.

Warning: Possible Injury.

 Risk of entanglement or 

injury may occur if mattress used with Mattress Side 

Stop does not fill the entire width between stops or 

which compresses to less than 1.5 inches under 

user’s weight.

Warning: Possible Injury or Death.

 Floor locks 

increase bed stability and resident safety. Make 

sure the bed is in a locked position with respect to 

the floor by ensuring the casters are off the floor or 

if equipped, the UltraLock is in the locked position 

before attempting any resident transfers. Failure to 

do so could result in injury or death. 

Warning: Possible Injury.

 Use caution when 

activating the UltraLock function. This feature was 

designed to be activated by your foot. Using your 

hand to activate the UltraLock system could result 

in injury.

Caution:

 In the absence of line voltage, all bed 

contouring can be achieved via an externally 

available backup battery (Joerns P/N N511). 

Joerns recommends a minimum of one battery for 

every twenty five beds per facility.

Caution:

 This device complies with EMC 

requirements of IEC 60601-1-2. Radio transmitting 

equipment, cellular phones or similar electronic 

devices, used in proximity of bed, may affect bed 

performance.

Caution: 

Particular precaution must be considered 

during exposure to strong emission sources such 

as High Frequency surgical equipment and similar 

devices. Do not route High Frequency cables 

on or near device. If in doubt, contact a qualified 

technician.

Caution:

 The Joerns’ EasyCare

®

 Bed Platform is 

intended for use within an institutional healthcare 

environment (ie: skilled nursing, transitional 

care, rehabilitational care, assisted living). 

Joerns Healthcare recommends compliance to 

the regulations and guidelines specified to your 

locality. 

This product is only one part of your healthcare 

bed system. Proper combinations of mattress, 

head/foot panels and assist devices are needed 

to minimize the risk of entrapment. For more 

information, call Customer Care, 800-826-0270.

Save These Instructions

Thank you and congratulations for choosing 

Joerns EasyCare Bed Platform. Joerns beds are 

developed with safety, comfort and convenience of 

both residents/patients and caregivers in mind. 

Advanced ergonomic design will provide years of 

reliable service in your facility.

Содержание ECS EasyCare 3

Страница 1: ...Joerns Healthcare EasyCare 5 EasyCare 7 EasyCare 9 User Service Manual Joerns EasyCare Bed Platform Model ECS leading bed evolution To avoid injury read user s manual before using EasyCare 3...

Страница 2: ...ble Shock Hazard Injury may result from improper routing of the power cord Always follow the proper factory installed routing configuration Failure to do so could result in injury or death Warning Pos...

Страница 3: ...less than 1 5 inches under user s weight Warning Possible Injury or Death Floor locks increase bed stability and resident safety Make sure the bed is in a locked position with respect to the floor by...

Страница 4: ...althcare can offer you the expertise assistance and products to bring your facility into compliance Joerns Compliance Solutions Matching the right bed components in order to meet regulatory guidelines...

Страница 5: ...Sensor EasyCare 9 Power 120 VAC Frequency 60 Hz Current Rating 4 0 Amps 120V Classification Class I Type B or Class II Type B Mode of Operation 10 Maximum Duty Cycle 2 minutes on 18 minutes off Circui...

Страница 6: ...face down 3 The foot panel brackets are the shorter of two sizes Figure 1 4 Install the foot panel brackets with the four screws provided The bracket offset should face up Figure 2 Do not tighten unti...

Страница 7: ...e mattress side stop into the hole on one side 6 Compress the mattress side stop and insert into the opposite hole on the head end of the mattress support platform IV Sockets Joerns EasyCare Bed Platf...

Страница 8: ...15 Operation Pendant Operation EasyCare 3 5 and 7 Your Joerns EasyCare 3 EasyCare 5 or EasyCare 7 bed comes standard with the snap in pendant The pendant has raised high contrast buttons and graphics...

Страница 9: ...e 19 Figure 20 Figure 21 Figure 22 EasyCare 9 1 Your EasyCare 9 bed comes standard with a pendant Figure 18 The pendant plugs into a port under either side of the seat pan 2 Unscrew the cap Figure 19...

Страница 10: ...ock graphic on the panel and push the function to unlock Amber LED is no longer illuminated signaling that the function is now operable Pendant Lockout and Bed Operation 1 Push button to lock out Back...

Страница 11: ...cked position by a red symbol Figure 28 3 To unlock the UltraLock place the ball of your foot on any pedal and push down Figure 29 The label indicates the mobile position by a green symbol Figure 28 W...

Страница 12: ...bed function fails to operate Ensure that the bed is not overloaded or constrained from movement Actuator and Control Box Information Cord and Socket Identification Figures 31 and 32 1 Back Actuator...

Страница 13: ...Control Box contain no serviceable parts Overload protection is achieved via current sensing technology which will automatically reset If any bed function fails to operate check to see if the bed is o...

Страница 14: ...ties that holds the power cable to the frame Tape the remaining cables in their original position It is very important to keep the actuator cables routed along the frame in their original factory ins...

Страница 15: ...es or less Do not surpass 10 duty cycle 2 min on 18 min off 2 If these steps fail to resolve the problem call Technical Support at 800 826 0270 1 Switch the pendant with a new pendant or one from a be...

Страница 16: ...ght in these locations Failure to do so could increase risk of suffocation or result in injury or death Warning Possible Injury The extender is designed for use with a foot panel Sitting on or sliding...

Страница 17: ...itable for use with the EasyCare Bed due to its low operating height 5 Adjustment and use of a Trapeze should be in accordance with instructions from a healthcare professional doctor or therapist 6 Do...

Страница 18: ...rest on the floor particularly when the bed is in its lowest position Otherwise a safety condition may occur or the function of attached items may be impacted Bed Transport Bar Figure 40 1 The Bed Tra...

Страница 19: ...he Battery will be fully charged Note We recommend that users charge up the Battery immediately upon receipt 4 The Battery has a useful life of about 3 5 years depending upon usage It is recommended t...

Страница 20: ...s Joerns beds contain various parts that wear from normal use These parts such as DC batteries are not covered under the three year warranty but are covered for 90 days after date of delivery Joerns H...

Отзывы: