Trapeze Adapter (Figure 35)

1. 

The Trapeze Adapter is designed to allow 

attachment of the Trapeze system to the 

EasyCare

®

 Bed. Prior to use, please read 

important warnings related to this option and follow 

all instructions below.

2. 

Install the Trapeze Adapter according to the 

supplied instructions.

 

3. 

Install the trapeze assembly onto the Trapeze 

Adapter according to the trapeze manufacturer’s 

instructions.

4. 

Operate the bed from its highest through lowest 

positions to ensure proper clearance and 

operation. Some trapeze systems may not be 

suitable for use with the EasyCare Bed, due to its 

low operating height. 

5. 

Adjustment and use of a Trapeze should be in 

accordance with instructions from a healthcare 

professional (doctor or therapist).

6.  Do not exceed the maximum load condition listed 

on installation instructions.

Drainage Bag Holder (Figure 36)

1.  The Drainage Bag Holder is designed as an 

attachment point for items such as urine collection 

bags. Make sure items attached to holder are 

safely secured. Prior to use, please read important 

warnings related to the Drainage Bag Holder and 

follow all instructions below.

2.  Install the Drainage Bag Holder and attach items 

to the Holder according to supplied instructions.

3.  It is important to operate all bed functions through 

their entire ranges to ensure that items attached 

to the Holder have proper clearance and are not 

pinched or caught.

4. 

Attach the Holder only to the point and position 

outlined in installation instructions. Operate all 

bed functions through their full ranges to ensure 

that items attached to the Holder have proper 

clearance and are not pinched or caught.

5. 

Many items that attach to the Holder are gravity 

fed and must be below bed user to function. Do 

not allow items suspended from the Holder to  

rest on the floor, particularly when the bed is in 

its lowest position. Otherwise, a safety condition 

may occur or the function of attached items may 

be impacted.

Figure 36

Figure 35

Содержание EasyCare

Страница 1: ...User Service Manual Joerns Bed Frames EasyCare Bed To avoid injury read user s manual before using...

Страница 2: ...rom any outlet Warning Possible Shock Hazard Injury may result from improper routing of the power cord Always follow the proper factory installed routing configuration Failure to do so could result in...

Страница 3: ...if mattress used with Mattress Side Stop does not fill the entire width between stops or which compresses to less than 1 5 inches under user s weight Warning Possible Injury or Death Floor locks incr...

Страница 4: ...Therefore compliance is the responsibility of the facility As the leading manufacturer of long term care beds and a frontrunner in addressing this critical issue Joerns Healthcare can offer you the ex...

Страница 5: ...tection LA27 Actuators Auto Reset Current Sensor Environmental Conditions Operating Conditions Ambient Temperature 10 C to 40 C Relative Humidity 30 to 75 Non Condensing Atmospheric Pressure 700 hPa t...

Страница 6: ...ain support of the bed panel Insert the safety pins on each side and latch them Figure 3 6 Press the mounting bracket against the bed frame and tighten the four panel mounting screws right and left si...

Страница 7: ...h 12 printed on it It is longer than the standard bumper 1 Remove the shorter bumper by tapping the tangs on either side of the leg with a rubber mallet 2 Place the 12 baseboard bumper 3 Tap into plac...

Страница 8: ...3 Ensure that the cable plug is fully inserted into the cable jack 4 To secure tighten the union nut on both cables Figure 14 Operation Pendant Operation Your EasyCare bed comes standard with one of t...

Страница 9: ...tion button Standard Staff Control Figure 21 2 1 4 6 5 3 7 Advanced Staff Control Figure 22 8 2 12 7 1 4 6 5 3 9 10 11 Head Operation 1 Push to raise Back 2 Push to lower Back Knee Operation 3 Push to...

Страница 10: ...Install correct baseboard bumper Bed Transport Roll in Low Lock System 1 To keep the bed from rolling when in the lowest position press down on the locking lever to lock casters Figure 23 2 The stand...

Страница 11: ...re 28 and 29 5 Release the tether to engage the detent Figure 27 6 Repeat the above steps on the remaining MSP extensions Warning Possible Injury Or Death Use a mattress that is properly sized to fit...

Страница 12: ...in intact and are securely fastened to their intended connection point Actuator and Control Box Information Warning Possible Shock Hazard Unplug the power cord from the wall outlet before performing a...

Страница 13: ...iver Masking Tape Zip Ties 5 16 Nut Driver 1 Raise the bed so that there is about 27 inches of clearance between the floor and the mattress support platform of bed 2 Unplug the power cable from the ou...

Страница 14: ...k of use check all threaded fasteners for looseness and make sure all pins are in their normal location and fastened securely Check monthly for loose bolts nuts pins and other retaining hardware Tight...

Страница 15: ...the floor and or cause the bed to become unstable resulting in injury or death Drainage Bag Holder Warning Possible BioHazard Prior to use consult the Drain Bag manufacturer s installation and use in...

Страница 16: ...igure 36 1 The Drainage Bag Holder is designed as an attachment point for items such as urine collection bags Make sure items attached to holder are safely secured Prior to use please read important w...

Страница 17: ...be fully charged Note We recommend that users charge up the Battery immediately upon receipt 4 The Battery has a useful life of about 3 5 years depending upon usage It is recommended to discharge the...

Страница 18: ...are covered for 90 days after date of delivery Joerns Healthcare s obligation under this warranty is limited to supplying replacement parts servicing or replacing at its option any product which is fo...

Отзывы: