65
·
Warning
!
●
All the electrical connection must meet local electrical connection
standard.
●
Only qualified electrical personnel can perform the wiring installation
work.
●
Incorrect wiring operation may cause operating casualties or equipment
damage permanently.
●
Ensure that there is no electricity in DC side before the electrical
connection.
●
Grounding correctly, using proper conductor and taking necessary
Short-circuit protection to ensure the safe operation of inverter.
●
Don’t switch on any breaker before all the electrical connection are
finished.
14.1 Connecting Terminals of Inverter
All connection terminals are at the bottom of the inverter, Remove the terminal
cover with a cross screwdriver, It contains DC side input (PV) terminal, AC
side AC input (AC IN), AC output (MOTOR) terminal, communication terminal
and water level sensor terminal inside The DC side input terminal, AC side
input and output terminals, and the grounding terminal are connected by a
terminal block.The communication terminal and water level sensor terminal
are connected by a signal terminal block.Please refer to Figure6-1.
Figure6-1 External connection terminals of inverter