40
·
Notice
!
Electrostatic discharging will cause damage to the inner components of
inverter. We should carry out the antistatic measure before disassembling
and assembling.
9.8.2 Mounting and dismounting of cover panel
For maintenance reason, you may need open the cover of inverter, and
ensure better seal performance, please operate according to the following
instruction.
1. When open the inverter cover, first use a cross screwdriver to remove the
grounding screw on the right side of the inverter case, and then use a 5#
Allen wrench to screw down the cover plate fixing screws in turn, and install
the gasket under the screw. When screwing down, pay attention to prevent
the gasket from falling off.
2. when cover it back, first use a cross screwdriver to lock the grounding
screw on the right side of the inverter case, then screw all the cover screws
into the screw holes, use a 5 × Allen wrench, with a torque of 1.8 ± 0.2N · m,
first lock the diagonal screws, and then lock the other screws in turn.
Figure6-12 Reference picture of Mounting and dismounting