background image

 
 

 

 

Instruction Manual 

ENGLISH 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Содержание TECH-D

Страница 1: ...Instruction Manual ENGLISH ...

Страница 2: ...n 7 10 2 3 Height level rods 11 2 4 Magnetic attachment 11 2 5 Height measuring rods 11 2 6 Level 11 2 7 Measuring sockets 12 2 8 Short measures 12 2 9 Change out batteries 13 2 10 Technical specification 14 4 Measuring 4 1 Mounting the magnetic attachment 31 4 2 Choose magnet attachment 32 4 3 Length measuring 33 4 4 Symmetry measuring 34 35 4 5 Comparing heights 36 4 6 Position of the vehicle 37...

Страница 3: ...ool and produce reports See separate software manual The measuring arm and its attachments and measuring tips together with web based software makes it possible to measure lengths in 2 dimensions You can also compare the symmetry in height between left and right side in a very time effective way These instructions contain a description of the equipment and directions for its use handling and maint...

Страница 4: ...from all of its great features B Maintenance Be sure to clean all equipment after every use Special care should be taken when cleaning the digital measuring arm in particular each of the moving surfaces Use a clean dry cloth without detergent Return all parts to the storage box after every use Check each part individually for any damage that may have occurred during use C Inspection Have your dist...

Страница 5: ...and maintenance The warranty assumes that TECH D equipment has been used and maintained in accordance with the instructions outlined in this manual Equipment has not been modified or rebuilt without the prior approval of JNE AB via its authorized distributor network Only genuine TECH D parts have been used in repairs Photos and drawings used throughout these instructions depict the fundamental fea...

Страница 6: ...he housing of the digital control unit with digital display located on the front end of the arm incorporates an easy to operate twist lock socket for each of the 3 different lengths of height measuring rods A level assembly is built into the top of the housing of the digital unit for identification of the vehicle s height divergences on symmetric points left and right side of the vehicle Measureme...

Страница 7: ...tch off by holding down the On 0 button for a few seconds and restart following the above procedure NORMAL MEASURING This is the automatic setting after start The measuring tool work in the area of 900 2650 mm SHORT MEASURES To measure short measures 400 2150 mm press for 2 seconds Use the tip holder that is attached underneath the measuring arm Use this measuring area preferably under hood COMPAR...

Страница 8: ...cond time to release this feature DISPLAY BRIGHTNESS Hold this button to increase display brightness release button when the required setting has been obtained ENERGY SAVING FUNCTION The display will automatically shut down after 5 minutes and be energised again at the slightest movement of the measuring arm SHUT OFF FUNCTION The display will shut down all circuits after 90 minutes of non operatio...

Страница 9: ..._______________________________ ______________________________________________________________________________ 9 TECH D manual EN 2010 05 18 doc Display functions ON 900 2650 400 2150 OFF Press 2 sek Press 1 Comparative measuring and Press 3 sek ...

Страница 10: ...__________________________________________ ______________________________________________________________________________ 10 TECH D manual EN 2010 05 18 doc Program menu measuring ON 900 400 OFF 1 sek Comparative measuring 2 sek 2 sek ...

Страница 11: ...arket Use it when a round or oval hole Ø35 mm is specified as the zero point on the vehicle dimension data sheet 2 5 Height measuring rods HEIGHT MEASURING RODS 3 rods are included Rod length is determined by the data sheet and should allow for the specified reading to be observed when the rod has been locked in place on the measuring arm Insert the rod into the measuring head at the front end of ...

Страница 12: ...0 26 mm 9 M201 adaptrar 6 18 1 90 holder Sockets and tips snap into the top of the height measuring rods 2 8 Short measures HOLDER FOR SHORT MEASURES POINT TO POINT On the measuring tool is an attachment for the holder for short measures Screw in the holder and choose suitable socket tip Measuring can now be done from 400 900 mm 2150 mm NOTE To change the measuring value to setting 400 2150 press ...

Страница 13: ...hat both batteries be replaced and that the old batteries be disposed of in accordance with local hazardous waste disposal regulations Batteries are located in a hidden compartment on the underside of the digital measuring head see photo Battery cover latch can be released by hand or small flat blade screwdriver NOTE Batteries should be installed according to the diagram molded into the inside of ...

Страница 14: ...ical specification Depending on if the measuring arm is pull out or together the accuracy of the level varies Refer to the table below for the amount of change in height at the measuring head for each graduation of movement in the level Extension in mm Change of height in mm 900 approx 0 5 1800 approx 1 0 2650 approx 1 5 Minimum and maximum measuring range The datum rods difference in height 100 m...

Страница 15: ...ed to ensure that it is being used correctly Likewise checking to see that the right vehicle has been selected in the database is equally important When in doubt check the above points thoroughly and if the problem persists contact the TECH D distributor or submit your question to our on line tech support Refer also to items 3 1 3 2 4 1 Mounting of the magnetic attachment Make sure that the mounti...

Страница 16: ...the height measuring rod and adaptor into the measuring tool and set it to the height dimension given on the data sheet 3 Mount the magnetic attachment in the intended attachment point under the vehicle Pull out and adjust the measuring tool so that the selected measurement point can be reached It can be advantageous here to use the hold feature to freeze the measurement value especially if it is ...

Страница 17: ...he vehicle It is however important that the height measuring rod be adjusted to the same height applicable to length measuring In all other aspects the same procedure as in length measuring applies 1 Read the height dimension given on the data sheet and select a suitable height rod Mount the height rod in the measuring head 2 Mount a suitable socket tip at the top of the height rod or the next eve...

Страница 18: ...e measuring arm s display and compare the symmetry cross measurement value with the value on the data sheet It can be advantageous here to enter the measured value in the data sheet table in order to create a before or after report Repeat the same procedure on the other side of the vehicle s corresponding and selected symmetry cross measurement point measuring line no 3 Note that the vehicle can h...

Страница 19: ...ways is done at the same time as length measurement i e when measurement is done parallel with the vehicle s centre line The water level on the TECH D arm is fixed which often means that it is not on the same level as the vehicle to check This means that the measuring value stated for the height rod in TECH D datasheet only is intended for the settings of the measuring arm when length measurements...

Страница 20: ...anding at an inclination of 2 If one goes out to 600 mm on the scale and down to 2 on the graduated scale this shows that the height difference is 21 mm from the centre line or depending on which side is measured The millimetre scale shows the height difference to be 100 mm from the centre depending on how many degrees the vehicle is inclined The example shows how important it is for the vehicle t...

Страница 21: ...he arm between centres A Move the measuring arm to the opposite side of the vehicle and fit the magnetic attachment to an equivalent measuring point B Take a similar length reading on this side C Compare readings Mount the magnetic attachment on a symmetrical undamaged point under the vehicle Cross check side to side from each magnetic mounting point to an equivalent measuring point on the opposit...

Страница 22: ... 6 ADAPTORS 6 1 Adaptors Product development of TECH D measurement tools is continuously in progress This also includes the development of different types of adapters both attachment and measurement adapters Your local TECH D distributor will keep you continuously informed of new product innovations If you have any special preferences or requirements contact your local TECH D distributor ...

Страница 23: ...0 EMK 1900 T Measuring tool 5 2 AVP1182 Measuring rod 100 1 1 EMC 1375 Front 5 3 AVP1200 Measuring rod 285 1 2 EMC 1281 Collar 2 5 4 AVP1210 Measuring rod 450 1 3 EMC 1291 Collar 3 6 1 AVP1110 Datum rod 1 4 EMC 1301 Collar 4 6 2 AVP1130 Datum rod 100 1 5 AVP 1361 Friction stick 1 6 EMC 1380 Battery cover AVP 1450 Battery 1 7 AVP 1320 Locking for collar 1 8 AVP 1320 2 Locking for collar 1 9 EMK 140...

Страница 24: ...200 S 597 24 Åtvidaberg SWEDEN Tel 46 0 120 109 90 Fax 46 0 120 109 40 E mail info jne se The following standards and or technical specifications which comply with good engineering practice in safety matters in force within the EEA have been applied Test report technical construction file normative document Ref No 02024 Issued by JNE AB Standard EN 55011 Class B EN 61000 6 2 2001 EN 61000 4 2 3 8 ...

Страница 25: ..._______________________________ ______________________________________________________________________________ 25 TECH D manual EN 2010 05 18 doc JNE AB Box 200 S 597 24 Åtvidaberg SWEDEN Tel 46 0 120 109 90 Fax 46 0 120 109 40 E mail info jne se ...

Отзывы: