7. RAPID GUIDE
7.1 Check list
Remember the following:
• Always grind off and carefully clean the surface to be tested
• Never use a rougher grinding material than the
3M Scotch Brite
soft grinding
wheel.
• Never make a material test twice in the same place.
• Never make a test on double (2 or more) layers of material if the material is
less than 1.2 mm thick.
• Always expose the material to be tested.
• Always measure with the Analyser vertical or horizontal – Never with an
inclination greater than 90
• Never carry out tests on the material unless the Analyser has been fitted and
fastened correctly in the lip clamp. (This will otherwise lead to an incorrect
measurement value and, if the material is thin, the Analyser will not start at
all).
• To rapidly check the function of the Analyser, make a test on the top of the lip
clamp. A measurement value should then be displayed. If this does not occur,
check the contact surfaces of the batteries, or if necessary change the
batteries).
• Never unscrew the Analyser, since this means that the guarantee will no
longer be valid and that its function can be affected.
• Remember that the measurement value given by the Analyser is an
approximate value and is to be taken as a general indication of the nature and
type of the material and not as an exact determination.
•
IMPORTANT: Always follow the vehicle manufacturer's recommended
repair method in any repair work!