CDC160 DVD Case Wrapper
TP 000 103 - 14 -
SECTION 4: ERRORS
The "Reset Default" light is flashing; the "Start/Stop" push button cannot be used.
Check that the pusher on the automatic side of the machine (at the back/bottom of the hopper) has
jammed. If the surface in front of the pusher is clear, press the "Reset Default" push button. The
light goes OFF. Press the 'Start/Stop" push button once again, the machine starts again.
If the "Heater" control light stays off whatever the position of the heater potentiometer,
there is something wrong on the heating circuitry.
Open the front panel cover by removing the two screws at the rear of the cover (figure 12).
Test the three 10 Amps fuses on the electronic board (figure. 13) with a continuity meter. If one of
the 10 Amps fuses is blown, replace the fuse.
If the "Heater" light is ON and the heater does not work, the heater block will need to be replaced
(see spare part list in Section 5 of this manual).
Remove 2 screws
and lift cover
Fig. 12
Fig. 13
Fuses