19
9.1. Impacting an obstacle
If the lift impacts an obstacle with the tracks during lowering, the lift remains stationary due to the mechanical
resistance encountered. To remove the object, press the “Up” button continuously until the obstacle can be remo-
ved.
9.2. Emergency lowering
Emergency lowering is an intervention in the lift control system and should only be undertaken by competent per-
sons. Nevertheless, in the event of a defect on the lift, it is possible to lower the lift to the lowermost position.
⚠
Emergency lowering should only be realised by persons instructed in operation of the lift.
Observe the “lowering” instructions.
-
Check that no objects or persons are in the hazardous zone of the lift.
-
Remove the cover for the safety catches on the columns. Secure the safety catches against engaging with
your own aids (e.g. wire/cable ties). If the safety catches are engaged, the lift must be raised with the aid
of suitable equipment for as long as necessary to unlock the safety catches manually.
-
Unscrew the cap nut from the hydraulic control block, loosen the socket screw carefully => The lift begins
to lower.
-
The lowering procedure should be observed at all times. Tighten the socket screw in the event of danger.
-
Lower the lift to the lowermost position.
-
Shut down the lift until the defective parts have been replaced and the lift is once again in a flawlessly safe
condition.
Содержание FOX 4000 H
Страница 11: ...9 6 3 Data sheets a Standard version with 4090 mm ...
Страница 12: ...10 b Lift column extension version with 4690 mm ...
Страница 13: ...11 6 4 Load distribution ...
Страница 14: ...12 6 5 Foundation plan ...
Страница 15: ...13 6 6 Electrical diagram and parts list ...
Страница 16: ...14 6 7 Hydraulic diagram and hydraulic parts list ...
Страница 32: ...30 12 7 Installation of covers pipe clips and hydraulic line ...
Страница 33: ...31 ...
Страница 34: ...32 Ensure that hydraulic hoses F G and I are firmly connected and no leaks are evident ...
Страница 37: ...35 12 10 Installation of limit switch ...
Страница 41: ...39 B Safety catch A Cable from control cabinet B Safety catch cable ...
Страница 42: ...40 C Shut off bar C Cable from control cabinet D Safety catch cable ...
Страница 43: ...41 D Limit switch A Cable contact for shut off bar B Crossbar C Connector D Cable gland Clamp 102 Clamp 104 ...
Страница 44: ...42 E Pump unit A Limit switch cable B Column extension cable bushing ...
Страница 45: ...43 A Limit switch cable C Cable sleeve Clamp 102 Clamp 111 ...
Страница 46: ...44 12 13 Filling and venting of hydraulic system Grounding Connection 400 V U1 U2 U3 Clamp 200 Clamp 201 ...
Страница 49: ...47 12 16 Dowel data sheet ...
Страница 62: ...60 16 CE Confirmation ...