SECTION 3 - CHASSIS, PLATFORM, & SCISSOR ARMS
31215079
3-75
Adjustment Verification of Actuator
1. Measure the plunger travel distance from energized
to de-energized position. The travel distance must
not be more than 1 in.
2. Verify plunger moves freely without binding.
3. If binding occurs, check the plunger rod. It should
not come into contact with the eye bolt. Also verify
the spacer is installed on the correct side of lever
arm.
4. Use digital multimeter to measure de-energized
state (0 to 1 ohms) and energized state (14 to 17
ohms) of actuator.
MAF15580
Figure 3-65. Adjustment Verification of Actuator