PAGE 34 of 53
Chapter 6
OPERATION
6.1. Setup of ROTIX on a Scanning Surface
1.
Determine the diameter of the
pipe or tube to be scanned.
Included in the
ROTIX
kit and in
this manual, are two setup charts
which indicate the number of links
required based on the diameter of
the pipe or tubing
(Fig. 121)
. Refer
to the appropriate chart based on
the number of probes to be used
when scanning.
2.
Assemble the appropriate configuration to the frame bar
(Fig. 122)
. Install the
wedge and probes that will be used
(see Slip Joint Probe Holder on page 14)
.
TIP:
The following example is a four probe configuration
for a 30.4 cm (12 in) pipe diameter.
Fig. 121
- Refer to setup chart
Fig. 122
- Assemble configuration