background image

24

 

                                                                                                                             JH INDUSTIRES INC. 

 

 Inboard Handle Maintenance, 

CONTINUED

 

HAND LEVER

 

   

INSERT MAINTENANCE STRUT

 

 

1.

 

(Hydraulic  Only)  While  in  the  rest  position 

(See 

Figure  16

)  remove  the  Rod  Eye  Bolt  from  the 

cylinder and slowly lower the cylinder and allow

 

       to hang loosely.  

 

 

 
 

Disconnect the hydraulic cylinder from the Edge

-

of

-

dock  during  maintenance  or  servicing.      

Failure to do so could result in death or serious 
injury.

 

 

2.

 

Using the hand lever, position the dockleveler in 
the full back position. 

(See Figure 18).

 

 

3.

 

While one person holds the hand lever down as 
shown  in 

(Figure  18), 

another  person  standing 

on  the  drive  surface,  must  position  the  lip  to  its 
full upright position as shown in 

(Figure 25). 

 

 

4.

 

With the ramp and lip in the full upright position, 
move the hand lever to the maintenance socket         
position  as  shown  in 

(Figure  25).   

Place  the 

round  side  of  the  handle  into  the  maintenance 
socket and the tapered end of the handle facing 
up.

 

 

REMOVE MAINTENANCE STRUT

 

 

1.

 

With  the  ramp  and  lip  in  the  full  back  position, 
move the hand lever back to the lever socket as 
shown in 

(Figure 18).

 

 

2.

 

While one person holds the hand lever down, as 
shown  in 

(Figure  18), 

another  person  standing 

on  the  drive  surface  must  position  the  lip  to  full 
back position as shown in 

(Figure 18). 

 

 

3.

 

Using  the  hand  lever  lower  the  dockleveler  to 
the rest  position  as  shown  in 

(Figure  22). 

While 

lowering  dockleveler  to  the  rest  position  it  is   
necessary to have another person use a pipe or 
similar  device  to  hold  the  lip  extender  link  from 
engaging  on  the  extender  pivot  bushing  as 
shown  in 

(Figure  23), 

to  prevent  the  lip  from     

extending out away from the dock.

 

 
 
 
 
 

 

Do not use hands or feet to hold lip extender link 
disengaged. Use of hands or feet could cause a 
pinch point resulting in  serious injury or death.

 

 

FIGURE 25

 

 

 

 

 
 
 
 

 
 

 
 
 
 

 

GENERAL MAINTENANCE

 
 

1.

 

Every  90  days,  with  the  dock  leveler  in  the               
maintenance  position,  inspect  all  moving  parts 
for  wear  or  damage.  Repair  or  replace,  as      
necessary.

 

 

2.  Inspect all welds, repair or replace as necessary.

 

 

3.

 

If linkage parts must be replaced due to wear or 

 

       damage,  raise  the  leveler  to  its  rear  most       

position  by  means  of  the  hand  lever  and         
SECURE  WITH  THE    MAINTENANCE  STRUT

(See Figure 25).

 

 

4.

 

Lubricate all grease fittings every 90 days.

 

 

5.

 

To  increase  spring  tension,  turn  bolts  in  evenly. 
To decrease spring tension, turn bolts out even-
ly. 

 

 

6.

 

Every  90  days  inspect  dock  bumpers.    4”  of 
bumper protection is required.  Worn, torn, loose 
or missing bumpers must be replaced.

 

 

7.

 

Every 90 days check all labels.  See Page 26 for 
part  numbers  and  location.    Replace  as             
necessary.

 

MAINTENANCE 
SOCKET

 

LIP

 

RAMP

 

LEVER

 

SOCKET

 

MOUNTING

 

PLATE

 

Tapered 
End of 
Tube

 

      WARNING

 

!

 

      WARNING

 

!

 

Содержание Copperloy EDGE-OF-DOCK SEL Series

Страница 1: ...ou have read and understand the Safety Practices Warnings Installation and Operating Instructions contained in this manual Failure to do so could result in serious injury or death Model ______________...

Страница 2: ......

Страница 3: ...mage resulting from the misuse of the EDGE OF DOCK THERE ARE NO WARRANTIES EXPRESSED OR IMPLIED WHICH EXTEND BEYOND THE DESCRIPTION ABOVE THERE IS NO WARRANTY OF MERCHANTABILITY OR OF FITNESS FOR A PA...

Страница 4: ...long with their definitions as directly referenced from ANSI Z535 4 1998 SAFETY NOTICE is the preferred signal word to address practices not related to personal injury The safety alert symbol shall no...

Страница 5: ...dockleveler with equipment material or people on or in the path of the ramp or lip DO NOT operate the dockleveler when anyone is in front of it DO NOT attempt to lift or lower the dockleveler ramp or...

Страница 6: ...REME CAUTION Do not place fingers or un insulated tools inside the control box Touching wires or other parts inside the control box could result in electrical shock death or serious injury Truck Bed P...

Страница 7: ...0 16000 24000 17000 25500 18000 27000 19000 28500 20000 30000 21000 22000 23000 24000 25000 WARNING CALCULATING CAPACITY Determining required leveler capacity Determine gross vehicle weight GVW lift t...

Страница 8: ...ons of dock leveling devices shall be made only with written permission of the original manufacturer When industrial vehicles are driven on and off transport vehicles during the loading and unloading...

Страница 9: ...a groove in concrete 1 2 deep between lines marked in steps 3 4 6 Tack weld transition plate to angle nosing in at least four places on 66 72 wide EOD s and six places on 78 84 EOD s 7 Install anchor...

Страница 10: ...s marked in steps 3 4 6 Place formed angle on dock making sure back edge of leg on top of dock is recessed in groove and both legs are tight against top and face of dock Increase depth or width of gro...

Страница 11: ...approach ramp and plug weld bolts to plate All anchor bolts must be installed in accordance with the manufacturer s instructions Improper installation may result in death or serious injury Do not ins...

Страница 12: ...ance per side of leveler See Figure 9 10 2 Follow the section that addresses your installation and then continue to the GENERAL INSTALLATION section on pages 13 14 of this manual 13 13 13 12 3 TYP LEV...

Страница 13: ...at the upper outside edges of the mounting plate and plug weld the two outer holes in the mounting plate if curb channel is not used install two 5 8 DIA anchors 4 Support dockleveler by inserting hand...

Страница 14: ...ion joints may cause the anchors to come loose and pull out Use of improperly installed anchor bolts may result in death or serious injury NOTICE All anchor bolt lengths must suit local codes and cond...

Страница 15: ...ts inside the control box could result in electrical shock death or serious injury could occur Place barricades around pit on dock floor and drive while installing maintaining or repairing dockleveler...

Страница 16: ...eveler in it s rest position must be greater than 1 3 4 Failure to do so will cause the hydraulic cylinder to bottom out under load resulting in permanent damage to the hydraulic cylinder 8 Assemble a...

Страница 17: ...DTH 1 1 2 29 12 12 LIP AND RAMP NOT SHOWN FOR CLARITY 13 12 32 4 1 2 LEVELER WIDTH 1 1 2 29 15 15 LIP AND RAMP NOT SHOWN FOR CLARITY STANDARD 10 x13 x4 MOLDED BUMPER 2 Hole OPTIONAL 12 x13 x4 MOLDED B...

Страница 18: ...ing Requirements Overload Setting 115VAC 1 Phase 13 6 Amps 20 Amps 13 6 Amps 230VAC 1 Phase 6 8 Amps 15 Amps 6 8 Amps 208 230VAC 3 Phase 3 7 3 4 Amps 10 Amps 3 7 3 4 Amps 460VAC 3 Phase 1 7 Amps 5 Amp...

Страница 19: ...If the lip touches loads before resting on carrier floor linkage must be disengaged Use hand lever to hold 12 ramp plate in the full back position and with a pipe or similar device disengage lip exte...

Страница 20: ...til the lip extender link is properly seated on the extender pivot bushing See Figure 18 FIGURE 18 5 3 Raise hand lever Lip will extend automatically as the ramp is lowered onto the truck bed See Figu...

Страница 21: ...not use legs or feet to move or hold hand lever 7 2 Pull back on the hand lever until the lip clears the truck bed See Figure 21 FIGURE 21 7 3 Raise hand lever and allow the ramp and lip to lower to t...

Страница 22: ...dequate overlap See figure 20 Do not operate the dockleveler when anyone is on or in front of it Stay clear of the dockleveler when it is moving Do not walk or drive on the dockleveler or lip until it...

Страница 23: ...ramp and lip in the full upright position move the hand lever to the maintenance socket location As shown in Figure 24 REMOVE MAINTENANCE STRUT 1 With the ramp and lip in the full back position move...

Страница 24: ...position as shown in Figure 18 3 Using the hand lever lower the dockleveler to the rest position as shown in Figure 22 While lowering dockleveler to the rest position it is necessary to have another p...

Страница 25: ...DS 1 The first choice for fluid is Citco AW 46 200 hydraulic fluid This is the fluid normally supplied by the factory and is suitable for a ambient temperature range of 10 to 100 Fahrenheit 23 C to 38...

Страница 26: ...ubber for wear 4 of projection is required Refer to parts lists and figures for parts listings Check hydraulic reservoir oil level Fill with hydraulic oil See pg 25 for oil type Check the breather ven...

Страница 27: ...the welds on the tubes at the moun ng plate near the edge of the dock are not keeping the EOD from going fully back The hand lever should be parallel with the ground when fully back Grind any welds to...

Страница 28: ...Pin 002 065 002 065 8 1 Upper Spring Linkage Bar 7224B01 7224B01 9 1 Lower Spring Linkage Bar 7225B01 7225B01 10 2 Extension Spring 5539B01 2 5539B01 5539B02 11 2 Nut Hx 3 8 16 Pltd 024 028 024 028 12...

Страница 29: ...2 5 17 20 3 23 24 15 17 20 14 4 LIP PLATE 19 21 Item Qty Part Description Part 20K Capacity 30K Capacity 22 1 Handle End Cap SEL 04 00016 SEL 04 00016 23 1 Inboard Handle Lever w Removable Cap SEL 02...

Страница 30: ...002 159 29 2 10x13x12 Steel Block Weldment 2 Hole SEL 01 00082 25 26 27 28 Item Qty Description Part 30 2 12 x13 x4 Molded Rubber Bumper Standard SEL 04 00015 31 8 Scr Hx Gr2 1 2 13 x 3 00 002 071 32...

Страница 31: ...mper interior side of right bumper Typ of two 2 SEL 12 00054 B EOD Danger Label Place on underside of Ramp Plate Typ of one 1 SEL 12 00050 B Hydraulic EOD Danger Placard Post near EOD Typ Of one 3 SEL...

Страница 32: ...lectrical box centered on box front 7 SEL 12 00053 C EOD Danger Label Place on exterior side of left bumper interior side of right bumper Typ of two 5 SEL 12 00101 EOD Warning Label Place on hydraulic...

Страница 33: ...33 JH INDUSTIRES INC S1 S2 B A HYDRAULIC SCHEMATICS...

Страница 34: ...ock Connections Disconnect Hot to A105 Black 12ga Disconnect Common to A103 White 12ga Disconnect Ground to A113 Green 12ga Terminal Block to Motor Box A111 to T1 T3 on Motor Black 12ga A112 to T2 T4...

Страница 35: ...120VAC Coil 06 00121 2 1 Overload 12 18amps 06 00127 3 2 Pushbutton 063 026 8 1 Single phase Terminal Block Label 12 00150 5 1 12 Pole Terminal Block 06 00006 4 1 6 25 x9 50 x5 75 Nema 12 Enclosure 0...

Страница 36: ...l Block Connections Disconnect L1 to A105 Black 12ga Disconnect L2 to A103 Red 12ga Disconnect Ground to A113 Green 12ga Terminal Block to Motor Box A111 to T1 T4 on Motor Black 12ga A112 to T2 T3 on...

Страница 37: ...2 1 Overload 5 5 8amps 06 00126 3 2 Pushbutton 063 026 8 1 Single phase Terminal Block Label 12 00150 5 1 12 Pole Terminal Block 06 00006 4 1 6 25 x9 50 x5 75 Nema 12 Enclosure 063 027 7 1 6 x9 Enclos...

Страница 38: ...3 002 9 1 Hydraulic Cylinder 1 1 2 Dia X 12 Stroke 063 001 063 001 10 1 90 6 SAE O Ring to 6 SAE 37 Long 063 022 063 022 11 1 Upper Hydraulic Cylinder Mtg Bracket 7438B01 7438B01 12 1 Push Button Cont...

Страница 39: ...Motor Connection A121 12ga Green to Motor Ground Connection A106 to Black Wire on Solenoid 1 Black 18ga A107 to Black Wire on Solenoid 2 Black 18ga A110 to White Wire on Solenoid 1 White 18ga A111 to...

Страница 40: ...C 1 6 2 5A 06 00125 06 00124 3 2 Pushbutton 063 026 9 1 Three phase Terminal Block Label 12 00150 5 2 7 Pole Terminal Block 06 00007 4 1 6 25 x9 50 x5 75 Nema 12 Enclosure 063 027 8 1 6 x9 Enclosure B...

Страница 41: ...90 6 SAE 37 to 6 O Ring 063 002 063 002 9 1 Hydraulic Cylinder 1 1 2 Dia X 12 Stroke 063 001 063 001 10 1 90 6 SAE O Ring to 6 SAE 37 Long 063 022 063 022 11 1 Upper Hydraulic Cylinder Mtg Bracket 74...

Страница 42: ...JH Industries Inc 1981 E Aurora Road Twinsburg OH 44087 Phone 1 330 963 4105 Fax 1 330 963 4111 Toll Free 1 800 321 4968 www copperloy com JH INDUSTIRES INC _...

Отзывы: