background image

How to set up a mail account on your tablet

Start the tablet and go to settings. Choose 'Accounts and backup', press 'Accounts' and then 'Add  
account'. Follow the steps in the tablet.

The OCPC = Intelligent pipe/cable combination for optimal fiber blowing conditions

The JetLogger has an intelligent pipe/cable combination build in, the Optimal Cable Pipe Combination 
system (OCPC system). The OCPC system is an intelligent system helping you to get the optimal pipe and 
cable combination for optimal blowing.

The OCPC will automatically calculate the optimal cable/pipe combination, based on the fact that the 
cable must not be more than 2/3 of the inner pipe diameter. It secures that you don’t choose a fiber that 
is not suited for your choice of pipe size, for example trying to fit a fiber with a diameter that is too big for 
the pipe. If you choose a pipe with a inner diameter size of 8,00 mm the OCPC system will only present 
the cables which are optimal for this pipe size. It is possible for you to override the recommendation from 
the OCPC system if you like.

BluSensor

The BluSensor will automatically monitor the surrounding temperature and humidity and transfer this  
data to the JetLogger protocol via a Bluetooth signal. The BluSensor is parred with the tablet via a 
unique ID-number, this is done during production. If you need to make a new connection, you'll find 
the ID-number on the backside of the BlueSensor. The BluSensor is operated by a built in battery with a 
15 year warranty. The battery is built in and can not be changed.

Low battery warning < 20 %

If the battery on the JetLogger is low, you will get a warning when the capacity hits 20 %. The warning 
will flash, but you can still go on with your work. But you have to replace/recharge the battery 
as soon as possible. You can not change the battery when you are doing a documentation process.

16

D A R E   T O   D O   I T   D I F F E R E N T L Y .

Содержание JetLogger V0

Страница 1: ...D A R E T O D O I T D I F F E R E N T L Y JetLogger Product model type V0 V1 V2 V3 V 21 04 JETLOGGER SAFETY INSTALLATION AND OPERATIONS MANUAL...

Страница 2: ...rm or by any means including photocopying recording or other electronic or mechanical methods without the prior written permission of the publisher For permission requests write to the publisher addre...

Страница 3: ...r operations other than those described in this manual are considered dangerous and are discouraged Use of this machine for work other than what is intended relieves the manufacturer from any responsi...

Страница 4: ...protocol 5 9 Set up tablet for new session 6 10 Do a new session with last used data 7 12 Open old session 8 13 Add a new pipe to tablet 9 14 Add a new cable to tablet 10 14 Delete session save and go...

Страница 5: ...tion by GPS the JetLogger is monitoring for every 1 0 m the air pressure speed distance and pushing force This parameter is presented live on the tablet giving the user a full view over the process Ex...

Страница 6: ...le Connect battery or power supply to the V0 Connect compressor to V0 make sure the air valve is closed Insert the pipe and cable used for the job Start by switch on the V0 by pushing the power button...

Страница 7: ...the Log Box Connect compressor to the fiber blowing machine remember to close the air valve and set the emergency valve and regulator in closed position Insert the pipe and cable used for the job Sta...

Страница 8: ...ween 1 Crash test protocol Used to perform a crash test and find max pushing force 2 New session Used when a new job must be documented 3 New session with last used data Used when a job must be docume...

Страница 9: ...ou will do crash test When all information is filled out the Start session box turns green Press on it to start If software is asking for connection to SparkFun Pro Micro press OK You can now start yo...

Страница 10: ...tion of the pipe Type in the pipe temperature use a separate temperature measuring equipment Chose cable You will see the list of cables that are stored in the memory If not already stored you can use...

Страница 11: ...k Yes in the box please read about safety Shutdown in section 12 Information about the humidity and temperature will come automatically from the BluSensor When all information is filled in the Start s...

Страница 12: ...art your installation and the system will document the job When you are finished with your installation press on End session Note the meter marking on cable and fill out this in the protocol under End...

Страница 13: ...en or Send your saved sessions If you want to open a session just press Open for that session you want to open You can see the full documentation for that specific session If you want to send or delet...

Страница 14: ...about the pipe and press save Now you can choose this pipe in the protocol 10 Add a new cable to tablet If you want to add a new cable to the JetLogger press on Add cable in the main menu and this men...

Страница 15: ...The tablet is protected and placed in the JetLogger Box The tablet can be removed from the box to make it easyer to read from Please observe that the tablet is not charged if it is removed and the tab...

Страница 16: ...e with a inner diameter size of 8 00 mm the OCPC system will only present the cables which are optimal for this pipe size It is possible for you to override the recommendation from the OCPC system if...

Страница 17: ...ight 11 4 kg For V1 V2 V3 logbox battery included 1 Height 180 mm 2 Length 445 mm 3 Width 250 mm 4 Weight 4 1 kg 17 D A R E T O D O I T D I F F E R E N T L Y 13 Documentation and disposal Ordering doc...

Страница 18: ...14 EC Declaration of Conformity 18 D A R E T O D O I T D I F F E R E N T L Y H kan Johansson...

Страница 19: ...15 Notes 19 D A R E T O D O I T D I F F E R E N T L Y...

Страница 20: ...D A R E T O D O I T D I F F E R E N T L Y JETLOGGER SAFETY INSTALLATION AND OPERATIONS MANUAL Version 2022 11...

Отзывы: