4.7 Inputs
Within the operating voltage range, all inputs are voltage-proof and overcurrent
protected. The JXM-IO-E30 has 3 separate VEXT_SEN connector pins which
should be used to supply the sensors. The connector pins output the battery volt-
age via a PTC thermistor. The output voltage can be read back in the device so
that a failure of the sensor supply can be detected.
Alternatively, the analog inputs can also be used as digital inputs (DI_PNP).
Analog inputs
Parameter
Description
Analog inputs
Abbreviation
AI
Quantity
8
Resolution
12 bits
Voltage measuring
JXM-IO-E30
JXM-IO-E30-O01
Rated measuring range
0 V … 5 V
0 V … 10 V
Overvoltage measure-
ment
5 V … 7 V
10 V … 12 V
Input resistance
≥ 35 kΩ
Load resistor
120 Ω
Maximum voltage
+32 V
Measuring accuracy
±2 % relating to the rated measuring range
Moving average filter
Filter depth range
1 ... 32
At 1 no filtering is active.
Measuring cycle
1 ms
Current measurement
Measuring range
0 mA ... 20 mA
Overcurrent range
21 mA ... 24 mA
Measuring accuracy
±1.5 % referred to the current measuring range 20
mA
Behavior in case of over-
current detection
In case of overcurrent, the current measurement is
interrupted. At the end of the overcurrent event, the
current measurement is automatically resumed.
As DI_PNP
H level
≥ 4.6 V
L level
≤ 1.6 V
Input frequency
Max. 10 Hz
Input resistance
≥ 35 kΩ
Tab. 18: