4.8 EMI values
The JVM-104-O15 has E1 approval according to ECE R10 Rev. 5 and CE con-
formity according to ISO 14982.
INFO
The USB port does not meet the immunity requirement of the E1 directive.
Therefore, use the USB port only for service purposes and not while the unit is in
operation.
Pulses to ISO
7637-2
Test pulse
Values
Functional class
1
-450 V
C
2a
+37 V
A
2b
+20 V
C
3a
-150 V
A
3b
+150 V
A
4
Ua1: -12 V / 50 ms
Ua2: -5 V / 500 ms
A (24 V systems)
Ua1: -6 V / 15 ms
Ua2: -2.5 V / 1000 ms
C (12 V systems)
5b
Load dump, capped
70 V / 2 Ω
A
Tab. 11:
Pulses to ISO 7637-2
Irradiation to ISO
11452
Parameter
Values
Functional class
Protection against RF
noise
20 MHz ... 2 GHz 30 V/m A
Tab. 12:
Irradiation to ISO 11452
ESD EN 61000-4-2
ESD EN 61000-4-2
Values
Functional class
Contact discharge
±4 kV (to conductive sur-
faces)
A
Discharge through air
±8 kV (to insulating sur-
faces)
A
Tab. 13: