PROBLEM
POSSIBLE CAUSE
REMEDY
Insufficient water
lubrication
Needle valves not properly adjusted
Adjust the needle valves
Air in the system
Open the manifold drain with pump on
Plugged lines
Remove debris from lubrication lines
Leakage from pump
manifold uni-valve
leakage holes
Damaged valve seal
Replace seals
Leakage from
discharge fitting
leakage holes
Damaged fittings or seals
Replace the fittings and/or seals
Pump oil leaking from
breather
Check oil level
Add oill as necessary
Verify use of proper oil type
See “Oil Specifications” on page 62
Water in pump oil
Cross head oil seal leak
Replace seal
Cold oil
Continue to run until oil temp
increases to adequate temperature
Engine will not return
to idle when control
gun dumping
Excessive hose back pressure
Reduce hose string length
Throttle control piston sticking
Repair throttle control unit
Engine will not
increase in speed
when control gun first
closes
Engine idle speed too low
Increase idle speed
Large gun nozzle
Decrease nozzle size
Insufficient water
lubrication
Needle valves not properly adjusted
Adjust the needle valves
Air in the system
Open the manifold drain with pump on
Plugged lines
Remove debris from lubrication lines
Poor packing life
Hot water
125°F max
Insufficient water flow
Adjust water flow
Dirty water
Clean/replace filter
Scored/pitted plunger
Replace plunger
Gland nut loose
Tighten nut
Содержание TwinForce Series
Страница 1: ...OPERATION MANUAL TwinForce Series Waterblast Unit...
Страница 2: ...Visual Safety System...
Страница 11: ...3 TwinForce Series Waterblast Unit...
Страница 22: ...14 Operation Manual...
Страница 42: ...34 Operation Manual...
Страница 48: ...40 Operation Manual...
Страница 52: ...44 Operation Manual...
Страница 100: ...92 Operation Manual...
Страница 104: ...96 Operation Manual...
Страница 106: ...A 2 Appendix A Technical Specifications...
Страница 107: ...B 1 TwinForce Series Waterblast Unit APPENDIX B LONG TERM STORAGE PROCEDURE...
Страница 108: ...B 2 Appendix B Long Term Storage Procedure...