![JETStream TwinForce Series Скачать руководство пользователя страница 55](http://html1.mh-extra.com/html/jetstream/twinforce-series/twinforce-series_operation-manual_3879678055.webp)
47
TwinForce™ Series Waterblast Unit
10. Once all of the bolts are removed, lift the
manifold off the pump (Figure 63).
Note:
The weight of the manifold is
approximately:
• 3000 Series: 90 lb. (41 kg)
• 3600/4200 Series: 165 lb. (75 kg)
11.
Remove the water lubrication fitting (
) from each stuffing box.
12. Remove the two bolts that secure each
plunger coupling (Figure 65) to the plung-
ers and remove the three couplings.
Note:
The coupling halves are matched
and must be kept together.
!
!
CAUTION
Use two people to lift the manifold. The Manifold
is heavy and failure to use two people may cause
serious injury.
Figure 63: Manifold Removal.
Figure 64: Lubrication Fittings.
Lubrication Fitting
Stuffing Box
Figure 65: Plunger Coupling Removal.
Plunger
Plunger Coupling
Содержание TwinForce Series
Страница 1: ...OPERATION MANUAL TwinForce Series Waterblast Unit...
Страница 2: ...Visual Safety System...
Страница 11: ...3 TwinForce Series Waterblast Unit...
Страница 22: ...14 Operation Manual...
Страница 42: ...34 Operation Manual...
Страница 48: ...40 Operation Manual...
Страница 52: ...44 Operation Manual...
Страница 100: ...92 Operation Manual...
Страница 104: ...96 Operation Manual...
Страница 106: ...A 2 Appendix A Technical Specifications...
Страница 107: ...B 1 TwinForce Series Waterblast Unit APPENDIX B LONG TERM STORAGE PROCEDURE...
Страница 108: ...B 2 Appendix B Long Term Storage Procedure...