EN
Fig.
19
5.3 Servo Fail-Safe
In all connected receivers we recommend disable Fail-Safe and set
it in the Central Box only.
•
Fail Safe
– switches on/off the Fail-Safe function. If the Fail-Safe
function is deactivated, there is no signal generated in any Central
Box outputs at signal loss. If you activate the Fail-Safe function, the
behavior of the Central Box output corresponds with the setting of
individual outputs (Out off, Hold, Fail-Safe).
•
Fail-Safe Delay
–
the period of time during which the last valid
servo positions are repeated if the signal loss is detected. After the
selected time has elapsed, the Central Box outputs behave
according to setting for each specific output.
•
Fail-Safe setup now …
- sets the current position for the Fail-
Safe value
•
Mode
- Fail-Safe mode for a specific Central Box output
◦
Hold:
repeats the last known servo position before the signal
loss
◦
Out OFF:
does not generate any signal for servos in case of the
signal loss
◦
Fail-Safe:
generates pre-set servo position (value) if signal loss
is detected. Can be programmed with slowdown (Speed)
31 EN