4.4
Out Pin Set
*CENTRAL BOX*: Out Pin Set
– pushing the
D
button (down arrow)
moves you to basic settings of particular outputs of the Central Box.
•
Set Output pin
-selection of the slot that will be used for the
following settings. In this menu the output deflection of the
selected output is displayed as a percentage. Y1 is the Central Box
output labeled 1, Y2 is the Central Box labeled 2, etc.
•
Function
– setup of alternative output functions. This function is
available only for these outputs:
Central Box 2
10/220
:
•
Y1 to Y13: Functions - Servo output, digital input, digital
output and Ditex
•
Y14 and Y15: Functions - Servo output, Servo output, digital
input, digital output, telemetry input, EX Bus, Ditex, S.BUS
output (only for Y15), telemetry input, and EX Bus
•
E1/R3: Functions - Telemetry input, JETIBOX, EX Bus and
receiver
Central Box 100:
•
Y1 to Y8: Functions - Servo output,
digital
input,
digital
output
•
OUT/IN: Digital input and digital output
•
EXT1: Functions - Telemetry input, JETIBOX and EX Bus
•
SetInChannel
– assigns the input channel (marked as Chx) to a
specific output (marked as Yx)
•
Reverse
– reverses the output direction
•
Signal Fault -
setting behavior of the receiver in case of signal loss
•
hold
- repeats the last valid deflection command before
signal loss
•
out off
– does not generate any signal for servo in case of
signal loss
•
FailSafe
– transition to preset deflection of individual outputs
•
FS position
– setup of the selected output deflection in case of
signal loss