EN
•
Maximal current
– the highest current detected by the Central
Box on the inputs during its operation
•
Min/Max Temper.
- the highest and the lowest temperature of
the Central Box during its operation (since the last manual reset)
Statistics of the received signal expressed in time
R1:
how long was the signal from the primary receiver available to
the Central Box
R2:
how long was the signal from the secondary receiver available
to the Central Box
R3:
how long was the signal from the third receiver available
to the Central Box 210/220
Statistics of the received signal expressed as a percentage
R1:
what percentage of the total operating time was the signal from
the primary receiver available to the Central Box
R2:
what percentage of the total operating time was the signal from
the secondary receiver available to the Central Box
R3:
what percentage of the total operating time was the signal from
the third receiver available to the Central Box 210/220
•
Over-I Monitor
(CB100/220)
- indication of servo output during
the operating time of the Central Box; (-) output is fine (x) the output
is overloaded
4.3
Setting
*CENTRAL BOX*: SETTING
– By pushing the
D
button (down
arrow) you get to the basic setting of the device.
•
Fail Safe
– switches on/off of the Fail Safe function. If the Fail
Safe
function is deactivated, there is no signal generated in any Central
Box outputs at the signal loss. If you activate the Fail Safe function,
you can also select how the Central Box responds at the signal loss
for each of the individual outputs (OUT off, hold, fail safe).
•
Signal Fault Delay
– the length of time from when the Central
Box detects a signal loss to when the programmed Fail Safe output
23 EN