42" and 48" Jenn-Air SxS (continued)
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
WARNING
Accessing Evaporator and Related Components
Remove the evaporator cover screws and
remove cover. With the cover removed, the
defrost components are accessible, see
figure 1
Remove 4 screws and drop down the evapo-
rator fan and duct assembly, see figure 2.
The fan assembly slides out of the duct, see
figure 3.
Figure 1
Figure 2
Figure 3
Bimetal
Defrost Heater