3-1
PRODUCT OPERATION
THEORY OF OPERATION
OVERVIEW
The refrigerator Constant Flow Temperature
Management System uses two thermistors
to monitor temperature changes inside the
refrigerator and freezer compartments. Two
electronic control boards are used in the re-
frigerator: a main electronic control board, and
a low voltage (Storage bin) board. The main
electronic control board manages the operation
of the variable capacity compressor (VCC), a
variable speed evaporator fan motor, and a
variable position air door. The air door allows
independent temperature control of the refrig-
erator and freezer compartments.
The main electronic control board seeks the
most efficient means possible to maintain
temperatures as it controls the operation and
speed of the compressor and the evaporator
fan motor. Higher fan speed is used before
increasing the compressor speed to minimize
power consumption. A nearly constant run
THE ELECTRONIC CONTROL PANEL
Note:
This information is written specifically
for the 42" French Door model but ap-
plies to Bottom Mount and SXS mod-
els with these exceptions. 42" and 48"
SXS models and 36" Bottom Mount
models have only one Deli Pan, the
42" FD model has two. The SXS air
circulation is slightly different.
time is sought at the lowest possible fan and
compressor speed.
Freezer temperatures can be set from 5°F
to –5
°
F (–15
°
C to –21
°
C). Refrigerator tem-
peratures can be set from 45
°
F to 33
°
F, (7
°
C
to 1
°
C).
The Adaptive Defrost Control (ADC) portion
of the main electronic control board utilizes
“pulsed defrost” technology to perform the
defrost function (see page 3-4).
The main electronic control board monitors the
water valve for total elapsed time and gallons
of water used. The number displayed on the
Water Filter Indicator (WFI) is the percentage
of filter usage remaining.
The numeric display can be set for Fahrenheit
or Celsius and displays the actual temperatures.
The display range for the refrigerator is from
27°F to 70
°
F (–2.8
°
C to 21
°
C). The normal
freezer display range is from –10
°
F to 70
°
F
(–23
°
C to 21
°
C). Temperatures above or below
these limits will be displayed at the correspond-
ing temperature limit. During Max Cool, the
freezer display will read –5
°
F (–21
°
C), and the
refrigerator will read 34
°
F (1
°
C).
The display will show the temperature setting
any time the actual temperature is within ±6
°
F
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
WARNING
Содержание JB36NXFXLW00
Страница 7: ...1 3 BOTTOM MOUNT FEATURES JB36NXFXLW00 JB36NXFXRW00 ...
Страница 8: ...1 4 FRENCH DOOR FEATURES JF42NXFXDW00 ...
Страница 9: ...1 5 SIDE BY SIDE FEATURES ...
Страница 10: ...1 6 NOTES ...
Страница 44: ...3 10 42 and 48 Integrated SXS Cabinet Air Flow Schamatic AIR CIRCULATION continued ...
Страница 46: ...3 12 NOTES ...
Страница 72: ...4 26 NOTES ...
Страница 83: ...6 4 NOTES ...
Страница 91: ......