6
SAFETY INSTRUCTIONS
WARNING
Do not attempt to light the grill if gas odor is
present. Contact customer service at
1-800-554-5799.
When lighting, keep your face and body as far
away from the burner as possible.
BEFORE LIGHTING
Inspect the gas supply hoses prior to turning on the
gas. If there is evidence of cuts, wear, or abrasion, it
must be replaced prior to use.
Only the pressure regulator and hose assembly
supplied with the unit should be used. Never
substitute regulators for those supplied with the grill.
Contact customer service for proper replacement.
Screw the regulator (type QCC1) onto the cylinder.
Leak check the hose and regulator connections with a
soap and water solution before operating the grill
(See “Leak Testing” instructions on page 15).
Do not turn “ON” the gas at the LP gas cylinder
unless the quick connect gas hose is properly
connected to the side burner gas pipe system and all
burner valves are in the “OFF” position.
LP GAS CYLINDER WARNING
1.
Do not store or use gasoline or other
flammable vapors and liquids in the vicinity of
this or any other appliance.
2.
A liquid propane cylinder not connected for
use should not be stored in the vicinity of this
or any other appliance.
3.
Do not store a spare liquid propane gas
cylinders under or near this appliance.
4.
Never fill the cylinder beyond 80 percent
capacity.
5.
Liquid propane cylinders must be fitted with
an Overfill Protection Device (OPD).
6.
If the information above is not followed
exactly, a fire causing death or serious injury
may occur.
USING THE SIDE BURNER
Inspect the gas supply hose prior to turning on
the gas. If there is evidence of cuts, wear or
abrasion, it must be replaced prior to use. Do not
use the side burner if gas odor is present.
Keep a spray bottle of soapy water near the grill
and check the connections before each use.
ROTISSERIE DRIVE MOTOR
To ensure continued protection against electric
shock:
Connect to properly grounded outlets only.
Keep extension cord connections dry and off the
ground.
Do not expose to rain.
Do not use indoors.
WARNING
1.
The outdoor cooking gas appliance and
its individual shutoff valve must be
disconnected from the gas supply piping
system during any pressure testing of that
system at test pressures in excess of 0.5
psi (3.5kpa).
2.
The outdoor cooking gas appliance must
be isolated from the gas supply piping
system by closing its individual manual
shutoff valve during any pressure testing
of the gas supply piping system at test
pressures equal to or less than ½ psi
(3.5kpa)
Содержание 720-0513