GAS HOOK-UP
Only the pressure regulator and hose assembly
supplied with the grill should be used. Any
replacement pressure regulator and hose assembly
must be specified by the grill manufacturer.
This is a liquid propane configured grill. Do not attempt
to use a natural gas supply unless the grill has been
pre-configured for natural gas use.
Total gas consumption (per hour) of the 720-0513
liquid propane gas grill with all burners set on “HI”:
Main burners 52,000 BTU/Hr.
Rear burner 12,000 BTU/Hr.
Side burner 12,000 BTU/Hr.
Searing main burner 21,000 BTU/Hr
Total
97,000 BTU/Hr.
LIQUID PROPANE CYLINDER REQUIREMENTS
(20 lb. Cylinder)
A dented or rusty liquid propane gas cylinder may be
hazardous and should be checked by your supplier.
Never use a cylinder with a damaged valve. The liquid
propane cylinder must be constructed and marked in
accordance with the specifications for liquid propane
cylinders by the United States Department of
Transportation (DOT) or the National Standard of
Canada, CAN/CSA-B339, Cylinders, Spheres and
Tubes for Transportation of Dangerous Goods
Commission.
The 20 lb. cylinder must have a shut off valve
terminating in a valve outlet specified, as applicable,
for connection type QCC1 in the standard for
compressed gas cylinder valve outlet and inlet
connection ANSI/CGA-V-1.
Storage of an outdoor cooking gas appliance indoor is
permissible only if the cylinder is disconnected and
removed from the outdoor cooking gas appliance.
The cylinder supply system must be arranged for
vapor withdrawal. The cylinder must include a collar to
protect the cylinder valve.
Manifold pressure: (operating) 10 inches water column
(W.C.), (non-operating) 11.2 inches water
column (W.C.).
The liquid propane cylinder must be fitted with an
Overfill Protection Device (OPD).
Remove plastic valve cover from the liquid propane
cylinder. Make sure the grill gas hoses do not
contact the grease tray or grill firebox when the
liquid propane cylinder is pushed into the cart.
CONNECTION
Your grill is equipped with gas supply orifices for use
only with liquid propane gas. It is also equipped
with a high capacity hose/regulator assembly for
connection to a standard 20 lb. liquid propane
cylinder (18-1/4 inches high, 12-1/4 inches
diameter).
To connect the liquid propane gas supply cylinder:
1.
The cylinder valve should be in the “OFF”
position. If not, turn the valve clockwise until it
stops.
2.
Make sure the cylinder valve has the proper
type 1 external male thread connections per
ANSI Z21.81.
3.
Make sure the burner valves are in the “OFF”
position.
4.
Inspect the valve connections, port and
regulator assembly. Look for any damage or
debris. Remove debris and inspect the hose for
damage.
5.
When connecting the regulator assembly to the
valve, use your hand to tighten the nut clockwise
until it stops. Use of a wrench could damage the
quick coupling nut and result in a hazardous
situation.
6.
Open the cylinder valve fully by turning the
valve counterclockwise.
7.
Before lighting the grill, use a soap and water
solution to check all the connections for leaks.
8.
If a leak is found, turn the cylinder valve off and
do not use the grill until a local liquid propane
dealer can make repairs.
DISCONNECTION
1. Turn off the burner valves and make sure
the grill is cool.
2. Turn off the tank valve by turning the
control knob clockwise until it stops
.
WARNING
Never attempt to use damaged or
obstructed equipment. See your local
liquid propane dealer for repair.