16
2. Lift out the searing side burner.
3.
Locate the Liquid propane orifice at the end of the valve
.
4.
Use 6 mm socket wrench or 6 mm nut driver to remove the
orifice. Replace with the Natural gas orifice
.
IMPORTANT: Check that the orifice is properly installed inside
of the valve.
5. Reinstall the searing side burner. Make sure that the igniter is
out of the way to allow proper positioning of burner. Use
Phillips screwdriver to attach the mounting screws.
6. Use Phillips screwdriver to reattach the igniter and searing
side burner plate.
7. Reinstall searing side burner cover. Use Phillips screwdriver
to attach mounting screws.
8.
Open the manual shutoff valve in the gas supply line. The
valve is open when the handle is parallel to the gas pipe.
9. Test all connections using an approved noncorrosive leak-
detection solution. Bubbles will show a leak. Correct any leak
found.
Record Conversion
1. The appliance nameplate is located inside the grill cabinet on
the left-hand cabinet side. With a permanent marker, check
the box next to “Natural gas” and mark through “LP -
Propane.”
In the last page of the Use and Care Guide, write “Converted to
Natural Gas.” Also record the conversion date and the technician/
company that performed the conversion.
NOTE: Place LP gas parts in plastic parts bag for future use and
keep with pack containing literature.
Adjust High Flame Setting Screw
When converting from LP to Natural gas, you will need to adjust
the high flame setting screw for ideal burner flame height.
1.
Remove each control knob for the main burners and side
burner by loosening the set screw with the hex key
.
A. Orifice
A. Orifice
A
A
A. Closed valve
B. Open valve
A
B