Installation and Operating Instructions ECOVARIO® 616, 616 D
56
Subject to change without notice!
Th e LEDs have the following functions:
System LED:
yellow:
NetX system runs without user application
green:
User application is running
off :
Option card has no NetX system
or no supply voltage.
Real Time Ethernet Status LED 1
Status
LED
1
red:
Bus error (cable not connected /
Status LED 2
IP settings not confi gured)
off :
No error or no supply voltage.
System LED
Real Time Ethernet Status LED 2
red:
System error
fl ashes red: Under confi guration or protocol stack expects confi guration
off :
No error or no supply voltage.
For process control and visualization of ECOVARIO® in the Profi net® network a Profi Drive compatible
controller can be used. For confi guration instructions and an application example with the PLC S7-1500
(manufacturer: Siemens) please refer to Application Note 33.
Th ere are two ways to implement the operation with Profi net® interface:
as a pure Profi net® application
communication with ECO Studio in parallel to the Profi net® bus operation.
Th e two ways are described in the following.
Pure Profi net® operation
Th e communication is handled exclusively via Profi net® (cf. Fig. 6.42). All CANopen messages and services
(PDO, Emergency, NMT etc.) are managed. For the ECOVARIOs e.g. a line-shaped or a star-shaped con-
nection via an IRT switch can be provisioned.
Fig. 6.47: Example: Profinet® operation of ECOVARIO® 616/616D with line-shaped connection
ECOVARIO with
Profinet interface
ECOVARIO with
Profinet interface
ECOVARIO with
Profinet interface